449 research outputs found

    Formation of a stable deacagonal quasicrystalline Al-Pd-Mn surface layer

    Get PDF
    We report the in situ formation of an ordered equilibrium decagonal Al-Pd-Mn quasicrystal overlayer on the 5-fold symmetric surface of an icosahedral Al-Pd-Mn monograin. The decagonal structure of the epilayer is evidenced by x-ray photoelectron diffraction, low-energy electron diffraction and electron backscatter diffraction. This overlayer is also characterized by a reduced density of states near the Fermi edge as expected for quasicrystals. This is the first time that a millimeter-size surface of the stable decagonal Al-Pd-Mn is obtained, studied and compared to its icosahedral counterpart.Comment: Submitted to Phys. Ref. Lett. (18 July 2001

    Hotel Intercontinental, en Ginebra (Suiza)

    Get PDF
    This is one of the largest hotels in Switzerland, having 400 bedrooms and a capacity for 800 guests, distributed in 15 storeys. There are also 3 restaurants, 3 bars, a dancing hall, a general hall, with installations for simultaneous translations, cinema shows, etc., with accommodation for 400 people, four lecture rooms, a number of luxurious shops, hairdressers and beauty salon, travelling agency, hot water pool, and other ameneties. Its main merit is the right choice of materials, and the simple, elegant style of its outer shape and interior decoration.Este hotel, que es uno de los mayores construidos en Suiza, cuenta, entre sus dependencias, con 400 habitaciones que pueden acoger a 800 huéspedes y distribuidas en 15 plantas; tres restaurantes; tres bares; un salón de baile; un salón para múltiples usos, equipado con instalaciones de traducción simultánea, de proyección, etc., y en el cual pueden ser servidos banquetes de 400 cubiertos; cuatro salas de conferencias; una serie de lujosas tiendas; peluquería y salón de belleza; agencias de viajes; piscina con agua caliente; etc. Su mayor atractivo reside en la acertada elección de los materiales empleados en su construcción, así como en la elegancia y sencillez de líneas exteriores y decoración interior

    The surface science of quasicrystals

    Get PDF
    The surfaces of quasicrystals have been extensively studied since about 1990. In this paper we review work on the structure and morphology of clean surfaces, and their electronic and phonon structure. We also describe progress in adsorption and epitaxy studies. The paper is illustrated throughout with examples from the literature. We offer some reflections on the wider impact of this body of work and anticipate areas for future development. (Some figures in this article are in colour only in the electronic version

    Lower levels of Caveolin-1 and higher levels of endothelial nitric oxide synthase are observed in abdominal aortic aneurysm patients treated with simvastatin

    Get PDF
    This study was undertaken to verify whether simvastatin modulates Cav-1/eNOS expression, and if this modulation is associated with changes in pro- and anti-inflammatory cytokine and Toll-like receptor 4 (TLR4) level in abdominal aortic aneurysm (AAA). It is a 1:2 case-control study of non-statin (n=12) and simvastatin-treated patients (n=24) who underwent open AAA repair. Simvastatin treatment decreased Cav-1 (p0.05) and increased IL-10 concentration (p=0.055); however, TLR4 expression was unaffected, suggesting that simvastatin influences Cav-1 and eNOS in the AAA wall by other mechanisms. Simvastatin may modulate Cav-1 and eNOS expression in the aneurysmal wall, indicating a potentially beneficial role for statins in AAA patients

    Using quantitative breath sound measurements to predict lung function following resection

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Predicting postoperative lung function is important for estimating the risk of complications and long-term disability after pulmonary resection. We investigated the capability of vibration response imaging (VRI) as an alternative to lung scintigraphy for prediction of postoperative lung function in patients with intrathoracic malignancies.</p> <p>Methods</p> <p>Eighty-five patients with intrathoracic malignancies, considered candidates for lung resection, were prospectively studied. The projected postoperative (ppo) lung function was calculated using: perfusion scintigraphy, ventilation scintigraphy, and VRI. Two sets of assessments made: one for lobectomy and one for pneumonectomy. Clinical concordance was defined as both methods agreeing that either a patient was or was not a surgical candidate based on a ppoFEV<sub>1</sub>% and ppoDLCO% > 40%.</p> <p>Results</p> <p>Limits of agreement between scintigraphy and VRI for ppo following lobectomy were -16.47% to 15.08% (mean difference = -0.70%;95%CI = -2.51% to 1.12%) and for pneumonectomy were -23.79% to 19.04% (mean difference = -2.38%;95%CI = -4.69% to -0.07%). Clinical concordance between VRI and scintigraphy was 73% for pneumonectomy and 98% for lobectomy. For patients who had surgery and postoperative lung function testing (<it>n </it>= 31), ppoFEV<sub>1</sub>% using scintigraphic methods correlated with measured postoperative values better than projections using VRI, (adjusted R<sup>2 </sup>= 0.32 scintigraphy; 0.20 VRI), however the difference between methods failed to reach statistical significance. Limits of agreement between measured FEV<sub>1</sub>% postoperatively and ppoFEV<sub>1</sub>% based on perfusion scintigraphy were -16.86% to 23.73% (mean difference = 3.44%;95%CI = -0.29% to 7.16%); based on VRI were -19.56% to 28.99% (mean difference = 4.72%;95%CI = 0.27% to 9.17%).</p> <p>Conclusions</p> <p>Further investigation of VRI as an alternative to lung scintigraphy for prediction of postoperative lung function is warranted.</p

    Highly efficient catalysis of the Kemp elimination in the cavity of a cubic coordination cage.

    Get PDF
    The hollow cavities of coordination cages can provide an environment for enzyme-like catalytic reactions of small-molecule guests. Here, we report a new example (catalysis of the Kemp elimination reaction of benzisoxazole with hydroxide to form 2-cyanophenolate) in the cavity of a water-soluble M8L12 coordination cage, with two features of particular interest. First, the rate enhancement is among the largest observed to date: at pD 8.5, the value of kcat/kuncat is 2 × 10(5), due to the accumulation of a high concentration of partially desolvated hydroxide ions around the bound guest arising from ion-pairing with the 16+ cage. Second, the catalysis is based on two orthogonal interactions: (1) hydrophobic binding of benzisoxazole in the cavity and (2) polar binding of hydroxide ions to sites on the cage surface, both of which were established by competition experiments

    In Vivo Evaluation of the Biocompatibility of Surface Modified Hemodialysis Polysulfone Hollow Fibers in Rat

    Get PDF
    Polysulfone (Psf) hollow fiber membranes (HFMs) have been widely used in blood purification but their biocompatibility remains a concern. To enhance their biocompatibility, Psf/TPGS (d-α-tocopheryl polyethylene glycol 1000 succinate) composite HFMs and 2-methacryloyloxyethyl phosphorylcholine (MPC) coated Psf HFMs have been prepared. They have been evaluated for in vivo biocompatibility and graft acceptance and compared with sham and commercial membranes by intra-peritoneal implantation in rats at day 7 and 21. Normal body weights, tissue formation and angiogenesis indicate acceptance of implants by the animals. Hematological observations show presence of post-surgical stress which subsides over time. Serum biochemistry results reveal normal organ function and elevated liver ALP levels at day 21. Histological studies exhibit fibroblast recruitment cells, angiogenesis and collagen deposition at the implant surface indicating new tissue formation. Immuno-histochemistry studies show non-activation of MHC molecules signifying biocompatibilty. Additionally, Psf/TPGS exhibit most favorable tissue response as compared with other HFMs making them the material of choice for HFM preparation for hemodialysis applications

    Do airway metallic stents for benign lesions confer too costly a benefit?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The use of self-expanding metallic stents (SEMAS) in the treatment benign airway obstruction is controversial.</p> <p>Methods</p> <p>To evaluate the safety and efficacy of SEMAS for this indication, we conducted a 10-year retrospective review at our tertiary medical centre.</p> <p>Results</p> <p>Using flexible bronchoscopy, 82 SEMAS (67% Ultraflex, 33% Wallstent) were placed in 35 patients with inoperable lesions, many with significant medical comorbidities (88%). 68% of stents were tracheal, and 83% of patients showed immediate symptomatic improvement. Reversible complications developed in 9% of patients within 24 hrs of stent placement. Late complications (>24 hrs) occurred in 77% of patients, of which 37% were clinically significant or required an interventional procedure. These were mainly due to stent migration (12.2%), fracture (19.5%), or obstructive granulomas (24.4%). The overall granuloma rate of 57% was higher at tracheal sites (59%) than bronchial ones (34%), but not significantly different between Ultraflex and Wallstents. Nevertheless, Wallstents were associated with higher rates of bleeding (5% vs. 30%, p = 0.005) and migration (7% vs. 26%, p = 0.026). Of 10 SEMAS removed using flexible bronchoscopy, only one was associated with incomplete removal of fractured stent wire. Median survival was 3.6 ± 2.7 years.</p> <p>Conclusion</p> <p>Ill patients with inoperable lesions may be considered for treatment with SEMAS.</p
    • …
    corecore