60 research outputs found

    Recommendations for wider adoption of clinical pharmacy in Central and Eastern Europe in order to optimise pharmacotherapy and improve patient outcomes

    Get PDF
    Clinical pharmacy as an area of practice, education and research started developing around the 1960s when pharmacists across the globe gradually identified the need to focus more on ensuring the appropriate use of medicines to improve patient outcomes rather than being engaged in manufacturing and supply. Since that time numerous studies have shown the positive impact of clinical pharmacy services (CPS). The need for wider adoption of CPS worldwide becomes urgent, as the global population ages, and the prevalence of polypharmacy as well as shortage of healthcare professionals is rising. At the same time, there is great pressure to provide both high-quality and cost-effective health services. All these challenges urgently require the adoption of a new paradigm of healthcare system architecture. One of the most appropriate answers to these challenges is to increase the utilization of the potential of highly educated and skilled professionals widely available in these countries, i.e., pharmacists, who are well positioned to prevent and manage drug-related problems together with ensuring safe and effective use of medications with further care relating to medication adherence. Unfortunately, CPS are still underdeveloped and underutilized in some parts of Europe, namely, in most of the Central and Eastern European (CEE) countries. This paper reviews current situation of CPS development in CEE countries and the prospects for the future of CPS in that region

    Breathing Out Completely Before Inhalation: The Most Problematic Step in Application Technique in Patients With Non-Mild Chronic Obstructive Pulmonary Disease

    Get PDF
    Background: Patient adherence to an inhaled medication application technique (A-ApplT) represents a major health-care issue in patients with chronic obstructive pulmonary disease (COPD). However, there is a lack of studies evaluating this issue thoroughly. The aim of our study was to introduce a universal easy-to-use method of assessing the A-ApplT to chronic medication in moderate to very severe COPD individuals.Methods: The Czech Multicenter Research Database of COPD (COPD CMRD), a large observational prospective study, was used as a source of clinical data. A-ApplT was evaluated using our Five Steps Assessment. This measure is based on dichotomous evaluation of each of five predefined consecutive application technique steps and can be used in all settings for all currently available inhalation systems in COPD subjects.Results: A total of 546 participants (75.0% men; mean age 66.7 years; mean forced expiratory volume in 1s 44.7%) were available for analysis. This represents 69.6% of all patients recruited in the COPD CMRD. Less than one third of patients presented their application technique without any erroneous steps. The most problematic steps were breathing out completely in one breath immediately before inhalation (step No. 3), and the actual inhalation maneuver (step No. 4). The total number of errors was similar for dry powder inhalers and pressurized metered-dose inhalers.Conclusion: Our novel instrument, Five Steps Assessment, is comfortable for use in routine clinical practice to explore A-ApplT. The A-ApplT in real-life patients with non-mild COPD was inadequate and patients should be repeatedly trained by properly (re-)educated medical staff

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 6060^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law EγE^{-\gamma} with index γ=2.70±0.02(stat)±0.1(sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25(stat)1.2+1.0(sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO

    European surveillance of antimicrobial consumption (ESAC) : systemic antiviral use in Europe

    Get PDF
    Objectives: To assess the total systemic antiviral use in Europe and to identify the antiviral substances most commonly used.Methods: Within the European Surveillance of Antimicrobial Consumption (ESAC; www.esac.ua.ac.be), using the anatomical therapeutic chemical (ATC) classification and defined daily dose (DDD) measurement unit, data on total (out- and inpatient) systemic antiviral use (ATC J05), aggregated at the level of the active substance, were collected for 2008, and use was expressed in DDD (WHO ATC/DDD, version 2010) per 1000 inhabitants per day (DID). Antiviral substances were grouped according to their main indication.Results: In Europe, 12 countries (Belgium, Croatia, Denmark, Estonia, Finland, France, Hungary, Italy, Luxembourg, Russia, Slovenia and Sweden) provided total (out- and inpatient) data and 4 countries (Austria, the Netherlands, Portugal and Norway) provided outpatient data only. Total systemic antiviral use varied by a factor of 10.95 between the country with the highest (3.53 DID in France) and the country with the lowest (0.32 DID in Croatia) use. HIV/AIDS antivirals represented more than 50% of the total antiviral use in most countries. The amount and spectrum of antivirals used varied greatly between countries.Conclusions: Our study demonstrated a wide variation of total systemic antiviral use in several European countries, as striking as that of outpatient systemic antibiotic, antimycotic and antifungal use. The variation is mainly determined by the use of HIV/AIDS antivirals. These observations should stimulate further analysis to understand the variation of specific antiviral substances. The ESAC data facilitate auditing of antiviral prescriptions and evaluation of the implementation of guidelines and public health policies.peer-reviewe
    corecore