937 research outputs found

    High-visibility photonic crystal fiber interferometer as multifunctional sensor

    Get PDF
    A photonic crystal fiber (PCF) interferometer that exhibits record fringe contrast (~40 dB) is demonstrated along with its sensing applications. The device operates in reflection mode and consists of a centimeter-long segment of properly selected PCF fusion spliced to single mode optical fibers. Two identical collapsed zones in the PCF combined with its modal properties allow high-visibility interference patterns. The interferometer is suitable for refractometric and liquid level sensing. The measuring refractive index range goes from 1.33 to 1.43 and the maximum resolution is ~1.6 × 10-5

    Tritordeum breads are well tolerated with preference over gluten-free breads in non-celiac wheat-sensitive patients and its consumption induce changes in gut bacteria

    Get PDF
    BACKGROUND The ingestion of wheat and other cereals are related to several gut disorders. The specific components responsible for non-celiac wheat-sensitivity (NCWS) may include gluten and other compounds. Tritordeum is a new cereal derived from crossing durum wheat with a wild barley species, which differs from bread wheat in its gluten composition. In the present work, we examined the response of NCWS patients to tritordeum bread Gastrointestinal symptoms as well as tritordeum acceptability, gluten immunogenic peptides excretion, and the composition and structure of the intestinal microbiota were evaluated. RESULTS Gastrointestinal symptoms of the subjects showed no significant change between the gluten-free bread and the tritordeum bread. Participating subjects rated tritordeum bread higher than the gluten-free bread. Analysis of the bacterial gut microbiota indicated that tritordeum consumption does not alter the global structure and composition of the intestinal microbiota, and only a few changes in some butyrate-producing bacteria were observed. CONCLUSIONS All the results derived from acceptability, biochemical and microbiological tests suggest that tritordeum may be tolerated by a sub-set of NCWS sufferers who do not require strict exclusion of gluten from their diet. (c) 2020 Society of Chemical Industry

    A transfer matrix method for the analysis of fractal quantum potentials

    Full text link
    The scattering properties of quantum particles on fractal potentials at different stages of fractal growth are obtained by means of the transfer matrix method. This approach can be easily adopted for project assignments in introductory quantum mechanics for undergraduates. The reflection coefficients for both the fractal potential and the finite periodic potential are calculated and compared. It is shown that the reflection coefficient for the fractal has a self-similar structure associated with the fractal distribution of the potential

    A beam-beam monitoring detector for the MPD experiment at NICA

    Full text link
    The Multi-Purpose Detector (MPD) is to be installed at the Nuclotron Ion Collider fAcility (NICA) of the Joint Institute for Nuclear Research (JINR). Its main goal is to study the phase diagram of the strongly interacting matter produced in heavy-ion collisions. These studies, while providing insight into the physics of heavy-ion collisions, are relevant for improving our understanding of the evolution of the early Universe and the formation of neutron stars. In order to extend the MPD trigger capabilities, we propose to include a high granularity beam-beam monitoring detector (BE-BE) to provide a level-0 trigger signal with an expected time resolution of 30 ps. This new detector will improve the determination of the reaction plane by the MPD experiment, a key measurement for flow studies that provides physics insight into the early stages of the reaction. In this work, we use simulated Au+Au collisions at NICA energies to show the potential of such a detector to determine the event plane resolution, providing further redundancy to the detectors originally considered for this purpose namely, the Fast Forward Detector (FFD) and the Hadron Calorimeter (HCAL). We also show our results for the time resolution studies of two prototype cells carried out at the T10 beam line at the CERN PS complex.Comment: 16 pages, 12 figures. Updated to published version with added comments and correction

    An approach to assess flooding and erosion risk for open beaches in a changing climate

    Get PDF
    This paper examines the vulnerability to flooding and erosion of four open beach study sites in Europe. A framework for the quantitative estimation of present and future coastal flood and erosion risks is established using methods, data and tools from across a range of disciplines, including topographic and bathymetric data, climate data from observation, hindcast and model projections, statistical modelling of current and future climates and integrated risk analysis tools. Uncertainties in the estimation of future coastal system dynamics are considered, as are the consequences for the inland systems. Different implementations of the framework are applied to the study sites which have different wave, tidal and surge climate conditions. These sites are: Santander, Spain—the Atlantic Ocean; Bellocchio, Italy—the Adriatic Sea; Varna, Bulgaria—the Black Sea; and the Teign Estuary, UK—the northern Atlantic Ocean. The complexity of each system is first simplified by sub-division into coastal "impact units" defined by homogeneity in the local key forcing parameters: wave, wind, tide, river discharge, run-off, etc. This reduces the simulation to that of a number of simpler linear problems which are treated by applying the first two components of the Source–Pathway–Receptor–Consequence (S–P–R–C) approach. The case studies reveal the flexibility of this approach, which is found useful for the rapid assessment of the risks of flooding and erosion for a range of scenarios and the likely effectiveness of flood defences

    Hydrostatic Pressure Sensing with High Birefringence Photonic Crystal Fibers

    Get PDF
    The effect of hydrostatic pressure on the waveguiding properties of high birefringence photonic crystal fibers (HiBi PCF) is evaluated both numerically and experimentally. A fiber design presenting form birefringence induced by two enlarged holes in the innermost ring defining the fiber core is investigated. Numerical results show that modal sensitivity to the applied pressure depends on the diameters of the holes, and can be tailored by independently varying the sizes of the large or small holes. Numerical and experimental results are compared showing excellent agreement. A hydrostatic pressure sensor is proposed and demonstrated using an in-fiber modal interferometer where the two orthogonally polarized modes of a HiBi PCF generate fringes over the optical spectrum of a broad band source. From the analysis of experimental results, it is concluded that, in principle, an operating limit of 92 MPa in pressure could be achieved with 0.0003% of full scale resolution

    The Surgical Infection Society revised guidelines on the management of intra-abdominal infection

    Get PDF
    Background: Previous evidence-based guidelines on the management of intra-abdominal infection (IAI) were published by the Surgical Infection Society (SIS) in 1992, 2002, and 2010. At the time the most recent guideline was released, the plan was to update the guideline every five years to ensure the timeliness and appropriateness of the recommendations. Methods: Based on the previous guidelines, the task force outlined a number of topics related to the treatment of patients with IAI and then developed key questions on these various topics. All questions were approached using general and specific literature searches, focusing on articles and other information published since 2008. These publications and additional materials published before 2008 were reviewed by the task force as a whole or by individual subgroups as to relevance to individual questions. Recommendations were developed by a process of iterative consensus, with all task force members voting to accept or reject each recommendation. Grading was based on the GRADE (Grades of Recommendation Assessment, Development, and Evaluation) system; the quality of the evidence was graded as high, moderate, or weak, and the strength of the recommendation was graded as strong or weak. Review of the document was performed by members of the SIS who were not on the task force. After responses were made to all critiques, the document was approved as an official guideline of the SIS by the Executive Council. Results: This guideline summarizes the current recommendations developed by the task force on the treatment of patients who have IAI. Evidence-based recommendations have been made regarding risk assessment in individual patients; source control; the timing, selection, and duration of antimicrobial therapy; and suggested approaches to patients who fail initial therapy. Additional recommendations related to the treatment of pediatric patients with IAI have been included. Summary: The current recommendations of the SIS regarding the treatment of patients with IAI are provided in this guideline
    • …
    corecore