1,278 research outputs found

    Falerii novi (comune di fabrica di Roma, provincia di viterbo, regione lazio)

    Get PDF
    As part of the AHRC-funded “Beneath the Surface of Roman Republican Cities” project (2015-17), our team is pursuing a full-coverage Ground Penetrating Radar (GPR) survey of the entire intra-mural area of the Roman town of Falerii Novi, in combination with an assessment of the unpublished pottery from the excavations of 1969-75: our objective is to further our knowledge and understanding of the Roman town and its earlier phases of settlement (Launaro et al. 2016; 2017)

    The use of confocal microscopy in quantifying changes in membrane potential

    Get PDF
    Monitoring the plasma membrane potential and its changes can be a time consuming and challenging task especially when conventional electrophysiological techniques are used. The use of potentiometricfluorophores, namely tetramethylrhodamine methylester (TMRM), and digital imaging devices (laser scanning confocal microscopy) provides reliable and time efficient method. Two scorpion pore-forming peptides, namely PP and OP1, were used as a tool to induce depolarization of the plasma membrane potential of neuroblastoma cell line and cardiac myocytes. Alternative methods for the neuroblastoma cells and cardiac myocytes were used. Depolarization of the neuroblastoma cells was calibrated with 140 mM KCl solution with 1 ìM valinomycin, after which intensity readers were substituted in the Nernst equation for quantification. Calibration of the alternative method used of the cardiac myocytes’ plasma membrane potential changes was calibrated with the use of 5, 20, 40, and 80 mM KCl solutions with 1 ìM valinomycin. A calibration curve was then constructed from which plasma membrane potential could be calculate

    Diffractive phase-shift lithography photomask operating in proximity printing mode

    Get PDF
    Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)A phase shift proximity printing lithographic mask is designed, manufactured and tested. Its design is based on a Fresnel computer-generated hologram, employing the scalar diffraction theory. The obtained amplitude and phase distributions were mapped into discrete levels. In addition, a coding scheme using sub-cells structure was employed in order to increase the number of discrete levels, thus increasing the degree of freedom in the resulting mask. The mask is fabricated on a fused silica substrate and an amorphous hydrogenated carbon (a:C-H) thin film which act as amplitude modulation agent. The lithographic image is projected onto a resist coated silicon wafer, placed at a distance of 50 mu m behind the mask. The results show a improvement of the achieved resolution - linewidth as good as 1.5 mu m - what is impossible to obtain with traditional binary masks in proximity printing mode. Such achieved dimensions can be used in the fabrication of MEMS and MOEMS devices. These results are obtained with a UV laser but also with a small arc lamp light source exploring the partial coherence of this source. (C) 2010 Optical Society of America18161638716405Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)FAPESP_BrasilCNPq_Brasi

    Quasiparticle properties in a density functional framework

    Get PDF
    We propose a framework to construct the ground-state energy and density matrix of an N-electron system by solving selfconsistently a set of single-particle equations. The method can be viewed as a non-trivial extension of the Kohn-Sham scheme (which is embedded as a special case). It is based on separating the Green's function into a quasi-particle part and a background part, and expressing only the background part as a functional of the density matrix. The calculated single-particle energies and wave functions have a clear physical interpretation as quasiparticle energies and orbitals.Comment: 12 pages, 1 figure, to be published in Phys. Rev.

    Occupational therapists’ views of using a virtual reality interior design application within the pre-discharge home visit process

    Get PDF
    This article has been made available through the Brunel Open Access Publishing Fund.Background: A key role of Occupational Therapists (OTs) is to carry out pre-discharge home visits (PHV) and propose appropriate adaptations to the home environment, to enable patients to function independently after hospital-home discharge. However, research shows that more than 50% of specialist equipment installed as part of home adaptations is not used by patients. A key reason for this is that decisions about home adaptations are often made without adequate collaboration and consultation with the patient. Consequently, there is an urgent need to seek out new and innovative uses of technology to facilitate patient/practitioner collaboration, engagement and shared decision making in the PHV process. Virtual reality interior design applications (VRIDAs) primarily allow users to simulate the home environment and visualise changes prior to implementing them. Customised VRIDAs, which also model specialist occupational therapy equipment, could become a valuable tool to facilitate improved patient/practitioner collaboration if developed effectively and integrated into the PHV process. Objective: To explore the perceptions of occupational therapists with regards to using VRIDAs as an assistive tool within the PHV process. Methods: Task-oriented interactive usability sessions, utilising the think-aloud protocol and subsequent semi-structured interviews were carried out with seven Occupational Therapists who possessed significant experience across a range of clinical settings. Template analysis was carried out on the think-aloud and interview data. Analysis was both inductive and driven by theory, centring around the parameters that impact upon the acceptance, adoption and use of this technology in practice as indicated by the Technology Acceptance Model (TAM). Results: OTs’ perceptions were identified relating to three core themes: (1) perceived usefulness (PU), (2) perceived ease of use (PEoU), and (3) actual use (AU). Regarding PU, OTs believed VRIDAs had promising potential to increase understanding, enrich communications and patient involvement, and improved patient/practitioner shared understanding. However, it was unlikely that VRIDAs would be suitable for use with cognitively impaired patients. For PEoU, all OTs were able to use the software and complete the tasks successfully, however, participants noted numerous specialist equipment items that could be added to the furniture library. AU perceptions were positive regarding use of the application across a range of clinical settings including children/young adults, long-term conditions, neurology, older adults, and social services. However, some “fine tuning” may be necessary if the application is to be optimally used in practice. Conclusions: Participants perceived the use of VRIDAs in practice would enhance levels of patient/practitioner collaboration and provide a much needed mechanism via which patients are empowered to become more equal partners in decisions made about their care. Further research is needed to explore patient perceptions of VRIDAs, to make necessary customisations accordingly, and to explore deployment of the application in a collaborative patient/practitioner-based context

    Comparative study between wet and dry etching of silicon for microchannels fabrication

    Get PDF
    FAPESP - FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULOIn this work we present a comparative study of two processes for the fabrication of an array of microchannels for microfluidics applications, based on integrated-circuit technology process steps, such as lithography and dry etching. Two different methods were investigated in order to study the resulting microstructures: wet and dry deep etching of silicon substrate. The typical etching depth necessary to the target application is 50 mu m.1093015FAPESP - FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULOFAPESP - FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO2016/09509-112. Conference on Advanced Fabrication Technologies for Micro/Nano Optics and Photonics3 a 5 de Fevereiro de 2019San Francisco, CA, Estados UnidosSPIE; Nanoscribe Gmb
    corecore