279 research outputs found

    Unconventional magnetism in all-carbon nanofoam

    Get PDF
    We report production of nanostructured carbon foam by a high-repetition-rate, high-power laser ablation of glassy carbon in Ar atmosphere. A combination of characterization techniques revealed that the system contains both sp2 and sp3 bonded carbon atoms. The material is a novel form of carbon in which graphite-like sheets fill space at very low density due to strong hyperbolic curvature, as proposed for ?schwarzite?. The foam exhibits ferromagnetic-like behaviour up to 90 K, with a narrow hysteresis curve and a high saturation magnetization. Such magnetic properties are very unusual for a carbon allotrope. Detailed analysis excludes impurities as the origin of the magnetic signal. We postulate that localized unpaired spins occur because of topological and bonding defects associated with the sheet curvature, and that these spins are stabilized due to the steric protection offered by the convoluted sheets.Comment: 14 pages, including 2 tables and 7 figs. Submitted to Phys Rev B 10 September 200

    Cardiac safety in cluster headache patients using the very high dose of verapamil (≥720 mg/day)

    Get PDF
    Use of high doses of verapamil in preventive treatment of cluster headache (CH) is limited by cardiac toxicity. We systematically assess the cardiac safety of the very high dose of verapamil (verapamil VHD) in CH patients. Our work was a study performed in two French headache centers (Marseilles–Nice) from 12/2005 to 12/2008. CH patients treated with verapamil VHD (≥720 mg) were considered with a systematic electrocardiogram (EKG) monitoring. Among 200 CH patients, 29 (14.8%) used verapamil VHD (877 ± 227 mg/day). Incidence of EKG changes was 38% (11/29). Seven (24%) patients presented bradycardia considered as nonserious adverse event (NSAE) and four (14%) patients presented arrhythmia (heart block) considered as serious adverse event (SAE). Patients with EKG changes (1,003 ± 295 mg/day) were taking higher doses than those without EKG changes (800 ± 143 mg/day), but doses were similar in patients with SAE (990 ± 316 mg/day) and those with NSAE (1,011 ± 309 mg/day). Around three-quarters (8/11) of patients presented a delayed-onset cardiac adverse event (delay ≥2 years). Our work confirms the need for systematic EKG monitoring in CH patients treated with verapamil. Such cardiac safety assessment must be continued even for patients using VHD without any adverse event for a long time

    Router-level community structure of the Internet Autonomous Systems

    Get PDF
    The Internet is composed of routing devices connected between them and organized into independent administrative entities: the Autonomous Systems. The existence of different types of Autonomous Systems (like large connectivity providers, Internet Service Providers or universities) together with geographical and economical constraints, turns the Internet into a complex modular and hierarchical network. This organization is reflected in many properties of the Internet topology, like its high degree of clustering and its robustness. In this work, we study the modular structure of the Internet router-level graph in order to assess to what extent the Autonomous Systems satisfy some of the known notions of community structure. We show that the modular structure of the Internet is much richer than what can be captured by the current community detection methods, which are severely affected by resolution limits and by the heterogeneity of the Autonomous Systems. Here we overcome this issue by using a multiresolution detection algorithm combined with a small sample of nodes. We also discuss recent work on community structure in the light of our results

    Structure, electrochemical properties and functionalization of amorphous CN films deposited by femtosecond pulsed laser ablation

    Get PDF
    Amorphous carbon nitride (a-C:N) material has attracted much attention in research and development. Recently, it has become a more promising electrode material than conventional carbon based electrodes in electrochemical and biosensor applications. Nitrogen containing amorphous carbon (a-C:N) thin films have been synthesized by femtosecond pulsed laser deposition (fs-PLD) coupled with plasma assistance through Direct Current (DC) bias power supply. During the deposition process, various nitrogen pressures (0 to 10 Pa) and DC bias (0 to ¿ 350 V) were used in order to explore a wide range of nitrogen content into the films. The structure and chemical composition of the films have been studied by using Raman spectroscopy, electron energy-loss spectroscopy (EELS) and high-resolution transmission electron microscopy (HRTEM). Increasing the nitrogen pressure or adding a DC bias induced an increase of the N content, up to 21 at.%. Nitrogen content increase induces a higher sp2 character of the film. However DC bias has been found to increase the film structural disorder, which was detrimental to the electrochemical properties. Indeed the electrochemical measurements, investigated by cyclic voltammetry (CV), demonstrated that a-C:N film with moderate nitrogen content (10 at.%) exhibited the best behavior, in terms of reversibility and electron transfer kinetics. Electrochemical grafting from diazonium salts was successfully achieved on this film, with a surface coverage of covalently bonded molecules close to the dense packed monolayer of ferrocene molecules. Such a film may be a promising electrode material in electrochemical detection of electroactive pollutants on bare film, and of biopathogen molecules after surface grafting of the specific affinity receptor.This work is produced with the financial support of the Future Program Lyon Saint-Etienne (PALSE) from the University of Lyon (ANR-11-IDEX-0007), under the “Investissements d'Avenir” program managed by the National Agency Research (ANR)

    A Phase Ib, open-label, dose-finding study of alpelisib in combination with paclitaxel in patients with advanced solid tumors

    Get PDF
    Phosphatidylinositol 3-kinase (PI3K) pathway activation is associated with resistance to paclitaxel in solid tumors. We assessed the safety and activity of alpelisib, an oral, selective PI3K p110\u3b1 inhibitor, plus paclitaxel in patients with advanced solid tumors. This Phase Ib, multicenter, open-label, dose-finding study, with a planned dose-expansion phase of alpelisib once daily (QD) plus fixed-dose paclitaxel, recruited patients with advanced solid tumors. For the dose-finding phase, the primary objective was determination of maximum tolerated and/or recommended Phase II dose of alpelisib plus paclitaxel, and the secondary objectives included the assessment of safety for this combination. From March 2014 to August 2016, 19 patients with advanced solid tumors were treated with alpelisib QD (300 mg, n=6; 250 mg, n=4; 150 mg, n=9) plus paclitaxel (80 mg/m2, per standard of care). During dose finding, five of 12 (41.7%) evaluable patients for MTD determination experienced dose-limiting toxicities: alpelisib 300 mg, Grade 2 hyperglycemia (n=1); alpelisib 250 mg, Grade 2 hyperglycemia (n=1), Grade 4 hyperglycemia and Grade 3 acute kidney injury (n=1); and alpelisib 150 mg, Grade 2 hyperglycemia (n=1) and Grade 4 leukopenia (n=1). The MTD of alpelisib when administered with paclitaxel was 150 mg QD. Most frequent all-grade AEs were diarrhea (73.7%; Grade 3/4 10.5%) and hyperglycemia (57.9%; Grade 3/4 31.6%). The planned dose-expansion phase was not initiated. Alpelisib plus paclitaxel has a challenging safety profile in patients with advanced solid tumors. This study was closed following the completion of the dosefinding phase. Clinical trial registration: ClinicalTrials.gov NCT02051751

    Synthesis of diamondlike carbon films with superlow friction and wear properties

    Full text link
    In this study, the authors introduce a new diamondlike carbon (DLC) film providing a friction coefficient of 0.001 and wear rates of 10{sup {minus}9} to 10{sup {minus}10} mm{sup 3}/N.m in inert-gas environments (e.g., dry nitrogen and argon). The film was grown on steel and sapphire substrates in a plasma enhanced chemical vapor deposition system that uses using a hydrogen-rich plasma. Employing a combination of surface and structure analytical techniques, they explored the structural chemistry of the resultant DLC films and correlated these findings with the friction and wear mechanisms of the films. The results of tribological tests under a 10-N load (creating initial peak Hertz pressures of 1 and 2.2 GPa on steel and sapphire test pairs, respectively) and at 0.2 to 0.5 m/s sliding velocities indicated that a close correlation exists between the friction and wear coefficients of DLC films and the source gas chemistry. Specifically, films grown in source gases with higher hydrogen-to-carbon ratios had the lowest fiction coefficients and the highest wear resistance. The lowest friction coefficient (0.001) was achieved with a film on sapphire substrates produced in a gas discharge plasma consisting of 25% methane and 75% hydrogen

    Alcohol-related brain damage in humans

    Get PDF
    Chronic excessive alcohol intoxications evoke cumulative damage to tissues and organs. We examined prefrontal cortex (Brodmann’s area (BA) 9) from 20 human alcoholics and 20 age, gender, and postmortem delay matched control subjects. H & E staining and light microscopy of prefrontal cortex tissue revealed a reduction in the levels of cytoskeleton surrounding the nuclei of cortical and subcortical neurons, and a disruption of subcortical neuron patterning in alcoholic subjects. BA 9 tissue homogenisation and one dimensional polyacrylamide gel electrophoresis (PAGE) proteomics of cytosolic proteins identified dramatic reductions in the protein levels of spectrin β II, and α- and β-tubulins in alcoholics, and these were validated and quantitated by Western blotting. We detected a significant increase in α-tubulin acetylation in alcoholics, a non-significant increase in isoaspartate protein damage, but a significant increase in protein isoaspartyl methyltransferase protein levels, the enzyme that triggers isoaspartate damage repair in vivo. There was also a significant reduction in proteasome activity in alcoholics. One dimensional PAGE of membrane-enriched fractions detected a reduction in β-spectrin protein levels, and a significant increase in transmembranous α3 (catalytic) subunit of the Na+,K+-ATPase in alcoholic subjects. However, control subjects retained stable oligomeric forms of α-subunit that were diminished in alcoholics. In alcoholics, significant loss of cytosolic α- and β-tubulins were also seen in caudate nucleus, hippocampus and cerebellum, but to different levels, indicative of brain regional susceptibility to alcohol-related damage. Collectively, these protein changes provide a molecular basis for some of the neuronal and behavioural abnormalities attributed to alcoholics

    A review of friction models in interacting joints for durability design.

    Get PDF
    This paper presents a comprehensive review of friction modelling to provide an understanding of design for durability within interacting systems. Friction is a complex phenomenon and occurs at the interface of two components in relative motion. Over the last several decades, the effects of friction and its modelling techniques have been of significant interests in terms of industrial applications. There is however a need to develop a unified mathematical model for friction to inform design for durability within the context of varying operational conditions. Classical dynamic mechanisms model for the design of control systems has not incorporated friction phenomena due to non-linearity behaviour. Therefore, the tribological performance concurrently with the joint dynamics of a manipulator joint applied in hazardous environments needs to be fully analysed. Previously the dynamics and impact models used in mechanical joints with clearance have also been examined. The inclusion of reliability and durability during the design phase is very important for manipulators which are deployed in harsh environmental and operational conditions. The revolute joint is susceptible to failures such as in heavy manipulators these revolute joints can be represented by lubricated conformal sliding surfaces. The presence of pollutants such as debris and corrosive constituents has the potential to alter the contacting surfaces, would in turn affect the performance of revolute joints, and puts both reliability and durability of the systems at greater risks of failure. Key literature is identified and a review on the latest developments of the science of friction modelling is presented here. This review is based on a large volume of knowledge. Gaps in the relevant field have been identified to capitalise on for future developments. Therefore, this review will bring significant benefits to researchers, academics and industrial professionals
    corecore