65 research outputs found

    Effects of partial coherence on frequency combs

    Get PDF
    We give an analytical model to study the deviations from an ideal frequency comb when the effects of random variations, from pulse to pulse, in the amplitude, phase, shape, chirp, and timing jitter are simultaneously taken into account. This model is consistent with the previous experimental research and extends the theoretical work on spectral line widths of mode-locked lasers

    Generation of very flat optical frequency combs from continuous-wave lasers using cascaded intensity and phase modulators driven by tailored radio frequency waveforms

    Get PDF
    We demonstrate a scheme, based on a cascade of lithium niobate intensity and phase modulators driven by specially tailored radio frequency waveforms to generate an optical frequency comb with very high spectral flatness. In this work we demonstrate a 10 GHz comb with ~40 lines with spectral power variation below 1-dB and ~60 lines in total. The number of lines that can be generated is limited by the power handling capability of the phase modulator, and this can be scaled without compromising the spectral flatness. Furthermore, the spectral phase of the generated combs in our scheme is almost purely quadratic which, as we will demonstrate, allows for very high quality pulse compression using only single mode fiber.Comment: 12 pages, 3 figures, replaced the older version with the published versio

    Comb-Based Radio-Frequency Photonic Filters with Rapid Tunability and High Selectivity

    Get PDF
    Photonic technologies have received considerable attention for enhancement of radio-frequency (RF) electrical systems, including high-frequency analog signal transmission, control of phased arrays, analog-to-digital conversion, and signal processing. Although the potential of radio-frequency photonics for implementation of tunable electrical filters over broad RF bandwidths has been much discussed, realization of programmable filters with highly selective filter lineshapes and rapid reconfigurability has faced significant challenges. A new approach for RF photonic filters based on frequency combs offers a potential route to simultaneous high stopband attenuation, fast tunability, and bandwidth reconfiguration. In one configuration tuning of the RF passband frequency is demonstrated with unprecedented (~40 ns) speed by controlling the optical delay between combs. In a second, fixed filter configuration, cascaded four-wave mixing simultaneously broadens and smoothes comb spectra, resulting in Gaussian RF filter lineshapes exhibiting extremely high (>60 dB) main lobe to sidelobe suppression ratio and (>70 dB) stopband attenuation.Comment: Updated the submission with the most recent version of the pape

    Final results from the PERUSE study of first-line pertuzumab plus trastuzumab plus a taxane for HER2-positive locally recurrent or metastatic breast cancer, with a multivariable approach to guide prognostication

    Get PDF
    Background: The phase III CLinical Evaluation Of Pertuzumab And TRAstuzumab (CLEOPATRA) trial established the combination of pertuzumab, trastuzumab and docetaxel as standard first-line therapy for human epidermal growth factor receptor 2 (HER2)-positive locally recurrent/metastatic breast cancer (LR/mBC). The multicentre single-arm PERtUzumab global SafEty (PERUSE) study assessed the safety and efficacy of pertuzumab and trastuzumab combined with investigator-selected taxane in this setting. Patients and methods: Eligible patients with inoperable HER2-positive LR/mBC and no prior systemic therapy for LR/mBC (except endocrine therapy) received docetaxel, paclitaxel or nab-paclitaxel with trastuzumab and pertuzumab until disease progression or unacceptable toxicity. The primary endpoint was safety. Secondary endpoints included progression-free survival (PFS) and overall survival (OS). Prespecified subgroup analyses included subgroups according to taxane, hormone receptor (HR) status and prior trastuzumab. Exploratory univariable analyses identified potential prognostic factors; those that remained significant in multivariable analysis were used to analyse PFS and OS in subgroups with all, some or none of these factors. Results: Of 1436 treated patients, 588 (41%) initially received paclitaxel and 918 (64%) had HR-positive disease. The most common grade 653 adverse events were neutropenia (10%, mainly with docetaxel) and diarrhoea (8%). At the final analysis (median follow-up: 5.7 years), median PFS was 20.7 [95% confidence interval (CI) 18.9-23.1] months overall and was similar irrespective of HR status or taxane. Median OS was 65.3 (95% CI 60.9-70.9) months overall. OS was similar regardless of taxane backbone but was more favourable in patients with HR-positive than HR-negative LR/mBC. In exploratory analyses, trastuzumab-pretreated patients with visceral disease had the shortest median PFS (13.1 months) and OS (46.3 months). Conclusions: Mature results from PERUSE show a safety and efficacy profile consistent with results from CLEOPATRA and median OS exceeding 5 years. Results suggest that paclitaxel is a valid alternative to docetaxel as backbone chemotherapy. Exploratory analyses suggest risk factors that could guide future trial design

    Final results from the PERUSE study of first-line pertuzumab plus trastuzumab plus a taxane for HER2-positive locally recurrent or metastatic breast cancer, with a multivariable approach to guide prognostication

    Get PDF

    The COVID-19 pandemic and its global effects on dental practice. An international survey

    Get PDF
    Objectives A multicentre survey was designed to evaluate the impact of COVID-19 outbreak on dental practice worldwide, estimate the COVID-19 related symptoms/signs, work attitudes and behaviour and the routine use of protective measures and personal protective equipment (PPE). Methods A global survey using a standardized questionnaire with research groups from 36 countries was designed. The questionnaire was developed and pretested during April 2020 and contained three domains: 1) personal data; 2) COVID-19 positive rate and symptoms/signs presumably related to the coronavirus; 3) working conditions and PPE adopted after the outbreak. Countries’ data were grouped by the country positive rate (CPR) during the survey period and by Gross-National-Income per capita. An ordinal multinomial logistic regression model was carried out with COVID-19 self-reported rate referred by dental professionals as dependent variable to assess the association with questionnaire items. Results A total of 52,491 questionnaires were returned with a male/female ratio of 0.63. Out of the total respondents, 7,859 dental professionals (15%) reported symptoms/signs compatible with COVID-19. More than half of the sample (n=27,818; 53%) stated to use FFP2/N95 masks, while 21,558 (41.07%) used eye protection. In the bivariate analysis, CPR and N95/FFP2 were significantly associated (OR=1.80 95%CI=1.60/2.82 and OR=5.20 95%CI=1.44/18.80, respectively), while Gross-National-Income was not statistically associated with CPR (OR=1.09 95%CI=0.97/1.60). The same significant associations were observed in the multivariate analysis. Conclusions Oral health service provision has not been significantly affected by COVID-19, although access to routine dental care was reduced due to country-specific temporary lockdown periods. While the dental profession has been identified at high-risk, the reported rates of COVID-19 for dental professionals were not significantly different to those reported for the general population in each country. These findings may help to better plan oral health care for future pandemic events

    Frequency-swept high-repetition rate optical source

    Get PDF
    International audienceWe propose and numerically validate an all-optical scheme to generate optical pulse trains with varying temporal pulse-to-pulse delay and pulse duration. Applying a temporal sinusoidal phase modulation followed by a shaping of the spectral phase enables us to maintain high-quality Gaussian temporal profiles

    Ultrawideband pulse generation based on overshooting effect in gain-switched semiconductor laser

    No full text
    We demonstrate an alternative procedure to achieve ultrawideband (UWB) radio-frequency (RF) doublet impulses. It is based on the overshooting effect appearing by biasing a semiconductor laser close to the threshold with a large-amplitude signal. Specifically, with an optical bandpass filter and an electrical lowpass filter, we easily obtain doublet-like impulses whose RF spectrum meets the UWB regulations. Furthermore, we have been able to propagate such signals through an optical fiber link of 118-km length. Though the technique is not flexible in terms of waveform generation, our method constitutes a reliable, easy, and low-cost alternative for RF UWB impulse generation
    • 

    corecore