    Design and Evaluation of a Non-Contact Bed-Mounted Sensing Device for Automated In-Home Detection of Obstructive Sleep Apnea: A Pilot Study

    Get PDF
    We conducted a pilot study to evaluate the accuracy of a custom built non-contact pressure-sensitive device in diagnosing obstructive sleep apnea (OSA) severity as an alternative to in-laboratory polysomnography (PSG) and a Type 3 in-home sleep apnea test (HSAT). Fourteen patients completed PSG sleep studies for one night with simultaneous recording from our load-cell-based sensing device in the bed. Subjects subsequently installed pressure sensors in their bed at home and recorded signals for up to four nights. Machine learning models were optimized to classify sleep apnea severity using a standardized American Academy of Sleep Medicine (AASM) scoring of the gold standard studies as reference. On a per-night basis, our model reached a correct OSA detection rate of 82.9% (sensitivity = 88.9%, specificity = 76.5%), and OSA severity classification accuracy of 74.3% (61.5% and 81.8% correctly classified in-clinic and in-home tests, respectively). There was no difference in Apnea Hypopnea Index (AHI) estimation when subjects wore HSAT sensors versus load cells (LCs) only (p-value = 0.62). Our in-home diagnostic system provides an unobtrusive method for detecting OSA with high sensitivity and may potentially be used for long-term monitoring of breathing during sleep. Further research is needed to address the lower specificity resulting from using the highest AHI from repeated samples

    Design and Evaluation of a Non-Contact Bed-Mounted Sensing Device for Automated In-Home Detection of Obstructive Sleep Apnea: A Pilot Study

    No full text
    We conducted a pilot study to evaluate the accuracy of a custom built non-contact pressure-sensitive device in diagnosing obstructive sleep apnea (OSA) severity as an alternative to in-laboratory polysomnography (PSG) and a Type 3 in-home sleep apnea test (HSAT). Fourteen patients completed PSG sleep studies for one night with simultaneous recording from our load-cell-based sensing device in the bed. Subjects subsequently installed pressure sensors in their bed at home and recorded signals for up to four nights. Machine learning models were optimized to classify sleep apnea severity using a standardized American Academy of Sleep Medicine (AASM) scoring of the gold standard studies as reference. On a per-night basis, our model reached a correct OSA detection rate of 82.9% (sensitivity = 88.9%, specificity = 76.5%), and OSA severity classification accuracy of 74.3% (61.5% and 81.8% correctly classified in-clinic and in-home tests, respectively). There was no difference in Apnea Hypopnea Index (AHI) estimation when subjects wore HSAT sensors versus load cells (LCs) only (p-value = 0.62). Our in-home diagnostic system provides an unobtrusive method for detecting OSA with high sensitivity and may potentially be used for long-term monitoring of breathing during sleep. Further research is needed to address the lower specificity resulting from using the highest AHI from repeated samples

    Automated Detection of Real-World Falls: Modeled from People with Multiple Sclerosis

    No full text
    Falls are a major health problem with one in three people over the age of 65 falling each year, oftentimes causing hip fractures, disability, reduced mobility, hospitalization and death. A major limitation in fall detection algorithm development is an absence of real-world falls data. Fall detection algorithms are typically trained on simulated fall data that contain a well-balanced number of examples of falls and activities of daily living. However, real-world falls occur infrequently, making them difficult to capture and causing severe data imbalance. People with multiple sclerosis (MS) fall frequently, and their risk of falling increases with disease progression. Because of their high fall incidence, people with MS provide an ideal model for studying falls. This paper describes the development of a context-aware fall detection system based on inertial sensors and time of flight sensors that is robust to imbalance, which is trained and evaluated on real-world falls in people with MS. The algorithm uses an auto-encoder that detects fall candidates using reconstruction error of accelerometer signals followed by a hyper-ensemble of balanced random forests trained using both acceleration and movement features. On a clinical dataset obtained from 25 people with MS monitored over eight weeks during free-living conditions, 54 falls were observed and our system achieved a sensitivity of 92.14%, and false-positive rate of 0.65 false alarms per day