90 research outputs found

    Technical Note: Formal blind intercomparison of HO<sub>2</sub> measurements in the atmosphere simulation chamber SAPHIR during the HOxComp campaign

    Get PDF
    Hydroperoxy radical (HO<sub>2</sub>) concentrations were measured during the formal blind intercomparison campaign HOxComp carried out in Jülich, Germany, in 2005. Three instruments detected HO<sub>2</sub> via chemical conversion to hydroxyl radicals (OH) and subsequent detection of the sum of OH and HO<sub>2</sub> by laser induced fluorescence (LIF). All instruments were based on the same detection and calibration scheme. Because measurements by a MIESR instrument failed during the campaign, no absolute reference measurement was available, so that the accuracy of individual instruments could not be addressed. Instruments sampled ambient air for three days and were attached to the atmosphere simulation chamber SAPHIR during the second part of the campaign. Six experiments of one day each were conducted in SAPHIR, where air masses are homogeneously mixed, in order to investigate the performance of instruments and to determine potential interferences of measurements under well-controlled conditions. Linear correlation coefficients (<i>R</i><sup>2</sup>) between measurements of the LIF instruments are generally high and range from 0.82 to 0.98. However, the agreement between measurements is variable. The regression analysis of the entire data set of measurements in SAPHIR yields slopes between 0.69 to 1.26 and intercepts are smaller than typical atmospheric daytime concentrations (less than 1 pptv). The quality of fit parameters improves significantly, when data are grouped into data subsets of similar water vapor concentrations. Because measurements of LIF instruments were corrected for a well-characterized water dependence of their sensitivities, this indicates that an unknown factor related to water vapor affected measurements in SAPHIR. Measurements in ambient air are also well-correlated, but regression parameters differ from results obtained from SAPHIR experiments. This could have been caused by differences in HO<sub>2</sub> concentrations in the sampled air at the slightly different locations of instruments

    Asymmetric effects of false positive and false negative indications on the verification of alerts in different risk conditions

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.Indications from alerts or alarm systems can be the trigger for decisions, or they can elicit further information search. We report an experiment on the tendency to collect additional information after receiving system indications. We varied the proclivity of the alarm system towards false positive or false negative indications and the perceived risk of the situation. Results showed that false alarm-prone systems led to more frequent re-checking following both alarms and non-alarms in the high risk condition, whereas miss-prone systems led to high re-checking rates only for non-alarms, representing an asymmetry effect. Increasing the risk led to more re-checks with all alarm systems, but it had a stronger impact in the false alarm-prone condition. Results regarding the relation of risk and the asymmetry effect of false negative and false positive indications are discussed

    Vorstufen zur Synthese eines [4.4]Paracyclophan-überbrückten Porphyrins

    No full text
    corecore