340 research outputs found

    Anisotropic valence-->core x-ray fluorescence from a [Rh(en)3][Mn(N)(CN)5]·H2O single crystal: Experimental results and density functional calculations

    Get PDF
    High resolution x-ray fluorescence spectra have been recorded for emission in different directions from a single crystal of the compound [Rh(en)3][Mn(N)(CN)5]·H2O. The spectra are interpreted by comparison with density functional theory (DFT) electronic structure calculations. The Kbeta[double-prime] line, which is strongly polarized along the Mn–N axis, can be viewed as an N(2s)-->Mn(1s) transition, and the angular dependence is understood within the dipole approximation. The so-called Kbeta2,5 region has numerous contributions but is dominated by Mn(4p) and C(2s)-->Mn(1s) transitions. Transition energy splittings are found in agreement with those of calculated occupied molecular orbitals to within 1 eV. Computed relative transition probabilities reproduce experimentally observed trends

    Combined SIMS-SPM Instrument For High Sensitivity And High Resolution Elemental 3D Analysis

    Get PDF
    Extended abstract of a paper presented at Microscopy and Microanalysis 2012 in Phoenix, Arizona, USA, July 29 - August 2, 201

    Effect of Wall Thickness and Surface Conditions on Creep Behavior of a Single-Crystal Ni-Based Superalloy

    Get PDF
    The influence of wall thickness and specimen surface on the creep behavior of the single-crystal nickel-based superalloy MAR M247LC is studied. Specimens with wall thicknesses of 0.4, 0.8, 1 and 2 mm, with and without casting surface, are compared to specimens of the same wall thickness prepared from bulk material. Creep behavior turned out to be independent from surface conditions even for the thinnest specimens. The thickness debit effect is not pronounced for short creep rupture times (le;100 h at 980 deg;C), whereas it is significant for creep rupture times longer than ~200 h at 980 deg;C. The thickness debit effect is time-dependent and caused by oxidation and diffusion-controlled mechanisms

    Work function of few layer graphene covered nickel thin films measured with Kelvin probe force microscopy

    Get PDF
    Few layer graphene and graphite are simultaneously grown on a similar to 100 nm thick polycrystalline nickel film. The work function of few layer graphene/Ni is found to be 4.15 eV with a variation of 50 meV by local measurements with Kelvin probe force microscopy. This value is lower than the work function of free standing graphene due to peculiar electronic structure resulting from metal 3d-carbon 2p(pi) hybridization. (C) 2016 AIP Publishing LLC

    Advanced atomic force microscopy techniques

    Get PDF
    Cataloged from PDF version of article.Although its conceptual approach is as simple as the technique used in record players already introduced in the 19th century, the invention of the atomic force microscope (AFM) in 1986 by Binnig, Quate, and Gerber was a milestone for nanotechnology. The scanning tunneling microscope (STM), introduced some years earlier, had already achieved atomic resolution, but is limited to conductive surfaces. Since its operational principle is based on the detection of the forces acting between tip and sample, this restriction does not exist for the AFM. Consequently, atomic force microscopy quickly became the standard tool for nanometer-scale imaging of all types of surfaces in all environments. True atomic resolution was first achieved in the 1990s. The most convincing results, however, were restricted to the so-called noncontact mode in vacuum for a long time, but recent technical developments overcame this limitation, and atomic-resolution imaging is now also a standard in liquids. Beyond pushing the resolution limit to the picometer range, the invention of the AFM triggered the development of a growing number of new scanning probe methods and approaches, ranging from an expansion of the properties that can be mapped to the active manipulation of surfaces and small particles. Practically every month, reports on the growing capabilities of AFMs appear. Nearly every physical effect that influences the tip–sample interaction has been used to improve existing modes and to develop new ones. For example, many recently presented techniques include the excitation of higher cantilever oscillation modes; it is amazing in how many ways the shaking of a simple cantilever can improve our knowledge about the tip–sample interaction. Another direction is high-speed atomic force microscopy, which is one of the eminent challenges that need to be solved in order to allow the in situ observation of biological processes. Data acquisition times have already reached the millisecond range, enabling the visualization of the dynamic behavior of biological molecules and cells. Other recent accomplishments include imaging of organic molecules with unprecedented resolution, full three-dimensional mapping of surface force fields, and the imaging and discrimination of individual chemical bonds. The development of advanced techniques is the focus of this Thematic Series, following the Thematic Series “Scanning probe microscopy and related techniques” edited by Ernst Meyer and the Thematic Series “Noncontact atomic force microscopy” edited by Udo Schwarz. The articles that are part of the series demonstrate that, despite its 25 years of history, the AFM is still far from reaching its limits, and today’s developments are far-reaching. As the number of research groups utilizing advanced atomic force microscopy techniques increases with each passing year, the technical improvements, data-acquisition approaches, analysis procedures, user friendliness, and application areas of the technique further diversify. With this Thematic Series, it is our intention to stimulate these improvements. We thank all authors for contributing their excellent work to this series. Furthermore, we acknowledge all referees for their promptly provided reports keeping the publication times short and attractive for contributors. Finally, we are grateful to the open access policy of the Beilstein Journal of Nanotechnology providing the ground for unrestricted discussions on advanced atomic force microscopy techniques. Thilo Glatzel, Hendrik Hölscher, Thomas Schimmel, Mehmet Z. Baykara, Udo D. Schwarz and Ricardo Garcia December 201

    Quantitative Shape-Classification of Misfitting Precipitates during Cubic to Tetragonal Transformations: Phase-Field Simulations and Experiments

    Get PDF
    The effectiveness of the mechanism of precipitation strengthening in metallic alloys de-pends on the shapes of the precipitates. Two different material systems are considered: tetragonal γ′′ precipitates in Ni-based alloys and tetragonal θ′ precipitates in Al-Cu-alloys. The shape formation and evolution of the tetragonally misfitting precipitates was investigated by means of experiments and phase-field simulations. We employed the method of invariant moments for the consistent shape quantification of precipitates obtained from the simulation as well as those obtained from the experiment. Two well-defined shape-quantities are proposed: (i) a generalized measure for the particles aspect ratio and (ii) the normalized λ2, as a measure for shape deviations from an ideal ellipse of the given aspect ratio. Considering the size dependence of the aspect ratio of γ′′ precipitates, we find good agreement between the simulation results and the experiment. Further, the precipitates’ in-plane shape is defined as the central 2D cut through the 3D particle in a plane normal to the tetragonal c-axes of the precipitate. The experimentally observed in-plane shapes of γ′′-precipitates can be quantitatively reproduced by the phase-field model. © 2021 by the authors. Licensee MDPI, Basel, Switzerland

    GPI-anchor signal sequence influences PrPC sorting, shedding and signalling, and impacts on different pathomechanistic aspects of prion disease in mice

    Get PDF
    The cellular prion protein (PrPC) is a cell surface glycoprotein attached to the membrane by a glycosylphosphatidylinositol (GPI)-anchor and plays a critical role in transmissible, neurodegenerative and fatal prion diseases. Alterations in membrane attachment influence PrPC-associated signaling, and the development of prion disease, yet our knowledge of the role of the GPI-anchor in localization, processing, and function of PrPC in vivo is limited We exchanged the PrPC GPI-anchor signal sequence of for that of Thy-1 (PrPCGPIThy-1) in cells and mice. We show that this modifies the GPI-anchor composition, which then lacks sialic acid, and that PrPCGPIThy-1 is preferentially localized in axons and is less prone to proteolytic shedding when compared to PrPC. Interestingly, after prion infection, mice expressing PrPCGPIThy-1 show a significant delay to terminal disease, a decrease of microglia/astrocyte activation, and altered MAPK signaling when compared to wild-type mice. Our results are the first to demonstrate in vivo, that the GPI-anchor signal sequence plays a fundamental role in the GPI-anchor composition, dictating the subcellular localization of a given protein and, in the case of PrPC, influencing the development of prion disease

    On the stability of very massive primordial stars

    Full text link
    The stability of metal-free very massive stars (ZZ = 0; M = 120 - 500 \msol) is analyzed and compared with metal-enriched stars. Such zero-metal stars are unstable to nuclear-powered radial pulsations on the main sequence, but the growth time scale for these instabilities is much longer than for their metal-rich counterparts. Since they stabilize quickly after evolving off the ZAMS, the pulsation may not have sufficient time to drive appreciable mass loss in Z = 0 stars. For reasonable assumptions regarding the efficiency of converting pulsational energy into mass loss, we find that, even for the larger masses considered, the star may die without losing a large fraction of its mass. We find a transition between the ϵ\epsilon- and κ\kappa-mechanisms for pulsational instability at Z\sim 2\E{-4} - 2\E{-3}. For the most metal-rich stars, the κ\kappa-mechanism yields much shorter ee-folding times, indicating the presence of a strong instability. We thus stress the fundamental difference of the stability and late stages of evolution between very massive stars born in the early universe and those that might be born today.Comment: 7 pages, 5 figures. Minor changes, more results given in Table 1, accepted for publication in Ap

    Dopant imaging of power semiconductor device cross sections

    Get PDF
    Several Scanning Probe Microscopy (SPM) methods allow to image dopant profiles in a range from 10(14) cm(-3) to 10(19) cm(-3) on semiconducting samples. In our work we present Scanning Capacitance Force Microscopy (SCFM) and Kelvin Probe Force Microscopy (KPFM) experiments performed on cross sections of silicon (Si) and silicon carbide (SiC) power devices and epitaxially grown calibration layers. The contact potential difference (CPD) shows under illumination a reduced influence on surface defect states. In addition results from numerical simulation of these microscope methods are discussed. (C) 2016 Elsevier B.V. All rights reserved

    X-ray Spectroscopic Study of Solvent Effects on the Ferrous and Ferric Hexacyanide Anions

    Get PDF
    We present an Fe K alpha resonant inelastic X-ray scattering (RIXS) and X-ray emission (XES) study of ferrous and ferric hexacyanide dissolved in water and ethylene glycol. We observe that transitions below the absorption edge show that the solvent has a distinct effect on the valence electronic structure. In addition, both the RIXS and XES spectra show a stabilization of the 2p levels when dissolved in water. Using molecular dynamics simulations, we propose that this effect arises from the hydrogen-bonding interactions between the complex and nearby solvent molecules. This withdraws electron density from the ligands, stabilizing the complex but also causing a slight increase in pi-backbonding
    • …
    corecore