193 research outputs found

    Development and test results of a readout chip for the GERDA experiment

    Get PDF
    This paper describes the F-CSA104 architecture and its measurement results. The F-CSA104 is for γ spectroscopy with Ge detectors. It is a low noise, fully integrated, four channel XFAB 0.6μm CMOS technology ASIC, that has been developed for the GERDA experiment. Each channel contains a charge sensitive preamplifier (CSA) followed by a 11.7MHz differential line driver. It has been particularly designed to operate in liquid argon (T = 87K/-186°C) and to have a measuring sensitivity of 660e- with an ENC of 110e-, after offline filtering with 10μs shaping, when connected to a 30pF load. Special techniques are used to improve the SNR such as a large input PMOS FET, an integrated 500MΩ CSA feedback resistor and a noise degeneration drain resistor

    Enhanced Radiation Hardness and Faster Front Ends for the Beetle Readout Chip

    Get PDF
    This paper summarizes the recent progress in the development of the 128 channel pipelined readout chip Beetle, which is intended for the silicon vertex detector, the inner tracker, the pile-up veto trigger and the RICH detectors of LHCb. Deficiencies found in the front end of the Beetle Version 1.0 and 1.1 chips resulted in the submissions of BeetleFE 1.1 and BeetleFE 1.2, while BeetleSR 1.0 implements test circuits to provide future Beetle chips with logic circuits hardened against single event upset (SEU). Section I. motivates the development of new front ends for the Beetle chip, and section II. summarizes their concepts and construction. Section III. reports preliminary results from the BeetleFE 1.1 and BeetleFE 1.2 chips, while section IV. describes the BeetleSR 1.0 chip. An outlook on future test and development of the Beetle chip is given in section V

    n-XYTER: A CMOS read-out ASIC for a new generation of high rate multichannel counting mode neutron detectors

    Get PDF
    For a new generation of 2-D neutron detectors developed in the framework of the EU NMI3 project DETNI [1], the 128-channel frontend chip n-XYTER has been designed. To facilitate the reconstruction of single neutron incidence points, the chip has to provide a spatial coordinate (represented by the channel number), as well as time stamp and amplitude information to match the data of x- and y-coordinates. While the random nature of the input signals calls for self-triggered operation of the chip, on-chip derandomisation and sparsi cation is required to exploit the enormous rate capability of these detectors ( 4 106cm2s1). The chosen architecture implements a preampli er driving two shapers with di erent time constants per channel. The faster shaper drives a single-pulse discriminator with subsequent time-walk compensation. The output of this circuit is used to latch a 14-bit time stamp with a 2 ns resolution and to enable a peak detector circuit fed by the slower shaper branch. The analogue output of the peak detector as well as the time stamp are stored in a 4-stage FIFO for derandomisation. The readout of these FIFOs is accomplished by a token-ring based multiplexer working at 32 MHz, which accounts for further derandomisation, sparsi cation and dynamic bandwidth distribution. The chip was submitted for manufacturing in AMS's C35B4M3 0.35µm CMOS technology in June 2006

    Development of a selftriggered high counting rate ASIC for readout of 2D gas microstrip neutron detectors

    Get PDF
    In the frame of the DETNI project a 32-channel ASIC suitable for readout of a novel 2D thermal neutron detector based on a hybrid low-pressure Micro-Strip Gas Chamber with solid 157Gd converter has been developed. Each channel delivers position information, a fast time stamp of 2 ns resolution and the signal amplitude (called energy below). The time stamp is used for correlating the signals from X and Y strips while the amplitude is used for finding the center of gravity of a cluster of strips. The timing and energy information are stored in derandomizing buffers and read out via token ring architecture

    Performance of the Beetle readout chip for LHCb

    Get PDF
    Beetle is a 128-channel readout chip, which will be used in the silicon vertex detector, the pile-up veto counters and the silicon tracker of the LHCb experiment at CERN. A further application of the Beetle chip is the readout of the LHCb RICH, in case it is equipped with multi-anode PMTs. The scope of this paper is the design changes leading to the latest version 1.3 of the Beetle readout chip. In addition, measurements on earlier versions and simulation results driving these changes are shown

    SEU Robustness, Total Dose Radiation Hardness and Analogue Performance of the Beetle Chip

    No full text
    The Beetle is a 128 channel readout chip for silicon strip detectors in LHCb. In addition to the pipelined readout path known from the RD20 architecture which can be used either in analogue or binary mode, the Beetle features an additional prompt binary readout path, used for the LHCb pile-up veto counters and a triple-redundant layout of the control logic. It is manufactured in commercial 0.25 µm CMOS technology using radiation hard design techniques. In addition to a total dose irradiation with X-rays, an SEU irradiation test with 65 MeV protons was performed with Beetle1.3. The results of this test are presented together with new results from the Beetle versions 1.3, 1.4 and 1.5, which were submitted in the Beetle ER engineering run in May 2004

    The LQG -- String: Loop Quantum Gravity Quantization of String Theory I. Flat Target Space

    Full text link
    We combine I. background independent Loop Quantum Gravity (LQG) quantization techniques, II. the mathematically rigorous framework of Algebraic Quantum Field Theory (AQFT) and III. the theory of integrable systems resulting in the invariant Pohlmeyer Charges in order to set up the general representation theory (superselection theory) for the closed bosonic quantum string on flat target space. While we do not solve the, expectedly, rich representation theory completely, we present a, to the best of our knowledge new, non -- trivial solution to the representation problem. This solution exists 1. for any target space dimension, 2. for Minkowski signature of the target space, 3. without tachyons, 4. manifestly ghost -- free (no negative norm states), 5. without fixing a worldsheet or target space gauge, 6. without (Virasoro) anomalies (zero central charge), 7. while preserving manifest target space Poincar\'e invariance and 8. without picking up UV divergences. The existence of this stable solution is exciting because it raises the hope that among all the solutions to the representation problem (including fermionic degrees of freedom) we find stable, phenomenologically acceptable ones in lower dimensional target spaces, possibly without supersymmetry, that are much simpler than the solutions that arise via compactification of the standard Fock representation of the string. Moreover, these new representations could solve some of the major puzzles of string theory such as the cosmological constant problem. The solution presented in this paper exploits the flatness of the target space in several important ways. In a companion paper we treat the more complicated case of curved target spaces.Comment: 46 p., LaTex2e, no figure

    Chemical analysis of acoustically levitated drops by Raman spectroscopy

    Get PDF
    An experimental apparatus combining Raman spectroscopy with acoustic levitation, Raman acoustic levitation spectroscopy (RALS), is investigated in the field of physical and chemical analytics. Whereas acoustic levitation enables the contactless handling of microsized samples, Raman spectroscopy offers the advantage of a noninvasive method without complex sample preparation. After carrying out some systematic tests to probe the sensitivity of the technique to drop size, shape, and position, RALS has been successfully applied in monitoring sample dilution and preconcentration, evaporation, crystallization, an acid–base reaction, and analytes in a surface-enhanced Raman spectroscopy colloidal suspension
    corecore