115 research outputs found

    The Evaluation of a Rapid In Situ HIV Confirmation Test in a Programme with a High Failure Rate of the WHO HIV Two-Test Diagnostic Algorithm

    Get PDF
    BACKGROUND: Concerns about false-positive HIV results led to a review of testing procedures used in a Médecins Sans Frontières (MSF) HIV programme in Bukavu, eastern Democratic Republic of Congo. In addition to the WHO HIV rapid diagnostic test algorithm (RDT) (two positive RDTs alone for HIV diagnosis) used in voluntary counselling and testing (VCT) sites we evaluated in situ a practical field-based confirmation test against western blot WB. In addition, we aimed to determine the false-positive rate of the WHO two-test algorithm compared with our adapted protocol including confirmation testing, and whether weakly reactive compared with strongly reactive rapid test results were more likely to be false positives. METHODOLOGY/PRINCIPAL FINDINGS: 2864 clients presenting to MSF VCT centres in Bukavu during January to May 2006 were tested using Determine HIV-1/2 and UniGold HIV rapid tests in parallel by nurse counsellors. Plasma samples on 229 clients confirmed as double RDT positive by laboratory retesting were further tested using both WB and the Orgenics Immunocomb Combfirm HIV confirmation test (OIC-HIV). Of these, 24 samples were negative or indeterminate by WB representing a false-positive rate of the WHO two-test algorithm of 10.5% (95%CI 6.6-15.2). 17 of the 229 samples were weakly positive on rapid testing and all were negative or indeterminate by WB. The false-positive rate fell to 3.3% (95%CI 1.3-6.7) when only strong-positive rapid test results were considered. Agreement between OIC-HIV and WB was 99.1% (95%CI 96.9-99.9%) with no false OIC-HIV positives if stringent criteria for positive OIC-HIV diagnoses were used. CONCLUSIONS: The WHO HIV two-test diagnostic algorithm produced an unacceptably high level of false-positive diagnoses in our setting, especially if results were weakly positive. The most probable causes of the false-positive results were serological cross-reactivity or non-specific immune reactivity. Our findings show that the OIC-HIV confirmation test is practical and effective in field contexts. We propose that all double-positive HIV RDT samples should undergo further testing to confirm HIV seropositivity until the accuracy of the RDT testing algorithm has been established at programme level

    Macrophages in Breast Cancer: Do Involution Macrophages Account for the Poor Prognosis of Pregnancy-Associated Breast Cancer?

    Get PDF
    Macrophage influx is associated with negative outcomes for women with breast cancer and has been demonstrated to be required for metastasis of mammary tumors in mouse models. Pregnancy-associated breast cancer is characterized by particularly poor outcomes, however the reasons remain obscure. Recently, post-pregnancy mammary involution has been characterized as having a wound healing signature. We have proposed the involution-hypothesis, which states that the wound healing microenvironment of the involuting gland is tumor promotional. Macrophage influx is one of the prominent features of the involuting gland, identifying the macrophage a potential instigator of tumor progression and a novel target for breast cancer treatment and prevention

    Ultra-conformal drawn-on-skin electronics for multifunctional motion artifact-free sensing and point-of-care treatment

    Get PDF
    An accurate extraction of physiological and physical signals from human skin is crucial for health monitoring, disease prevention, and treatment. Recent advances in wearable bioelectronics directly embedded to the epidermal surface are a promising solution for future epidermal sensing. However, the existing wearable bioelectronics are susceptible to motion artifacts as they lack proper adhesion and conformal interfacing with the skin during motion. Here, we present ultra-conformal, customizable, and deformable drawn-on-skin electronics, which is robust to motion due to strong adhesion and ultra-conformality of the electronic inks drawn directly on skin. Electronic inks, including conductors, semiconductors, and dielectrics, are drawn on-demand in a freeform manner to develop devices, such as transistors, strain sensors, temperature sensors, heaters, skin hydration sensors, and electrophysiological sensors. Electrophysiological signal monitoring during motion shows drawn-on-skin electronics' immunity to motion artifacts. Additionally, electrical stimulation based on drawn-on-skin electronics demonstrates accelerated healing of skin wounds. Designing efficient wearable bioelectronics for health monitoring, disease prevention, and treatment, remains a challenge. Here, the authors demonstrate an ultra-conformal, customizable and deformable drawn-on-skin electronics which is robust to motion artifacts and resistant to physical damage

    Monoclonal Antibody and Fusion Protein Biosimilars Across Therapeutic Areas: A Systematic Review of Published Evidence

    Get PDF

    Evaluation of appendicitis risk prediction models in adults with suspected appendicitis

    Get PDF
    Background Appendicitis is the most common general surgical emergency worldwide, but its diagnosis remains challenging. The aim of this study was to determine whether existing risk prediction models can reliably identify patients presenting to hospital in the UK with acute right iliac fossa (RIF) pain who are at low risk of appendicitis. Methods A systematic search was completed to identify all existing appendicitis risk prediction models. Models were validated using UK data from an international prospective cohort study that captured consecutive patients aged 16–45 years presenting to hospital with acute RIF in March to June 2017. The main outcome was best achievable model specificity (proportion of patients who did not have appendicitis correctly classified as low risk) whilst maintaining a failure rate below 5 per cent (proportion of patients identified as low risk who actually had appendicitis). Results Some 5345 patients across 154 UK hospitals were identified, of which two‐thirds (3613 of 5345, 67·6 per cent) were women. Women were more than twice as likely to undergo surgery with removal of a histologically normal appendix (272 of 964, 28·2 per cent) than men (120 of 993, 12·1 per cent) (relative risk 2·33, 95 per cent c.i. 1·92 to 2·84; P < 0·001). Of 15 validated risk prediction models, the Adult Appendicitis Score performed best (cut‐off score 8 or less, specificity 63·1 per cent, failure rate 3·7 per cent). The Appendicitis Inflammatory Response Score performed best for men (cut‐off score 2 or less, specificity 24·7 per cent, failure rate 2·4 per cent). Conclusion Women in the UK had a disproportionate risk of admission without surgical intervention and had high rates of normal appendicectomy. Risk prediction models to support shared decision‐making by identifying adults in the UK at low risk of appendicitis were identified

    Use of the hupB Gene Encoding a Histone-Like Protein of Mycobacterium tuberculosis as a Target for Detection and Differentiation of M. tuberculosis and M. bovis

    No full text
    The gene for histone-like protein (hupB [Rv2986c]) of Mycobacterium tuberculosis has been identified as a singular target which allows differentiation of two closely related mycobacterial species, namely, M. tuberculosis and M. bovis of the MTB complex, by a PCR assay. The N and S primer-generated PCR amplicons differed in M. tuberculosis and M. bovis; these amplicons were determined to be 645 and 618 bp, respectively. This difference was localized to the C-terminal part of the gene by using primers M and S. The C-terminal PCR amplicons of M. tuberculosis and M. bovis were determined to be 318 and 291 bp, respectively. The differences in the C-terminal portion of the gene were confirmed by restriction fragment length polymorphism analysis and sequencing. Sequence analysis indicated that in M. bovis there was a deletion of 27 bp (9 amino acids) in frame after codon 128 in the C-terminal part of the hupB gene. In the present study 104 mycobacterial strains and 11 nonmycobacterial species were analyzed for hupB gene sequences. Of the 104 mycobacterial strains included, 62 belonged to the MTB complex and 42 were non-MTB complex strains and species. Neither the hupB gene-specific primers (N and S) nor the C-terminal primers (M and S) amplify DNA from any other mycobacteria, making the assay suitable for distinguishing members of the MTB complex from other mycobacterial species, as well as for differentiating between members of the MTB complex, namely, M. tuberculosis and M. bovis

    Transcranial magnetic stimulation of the left angular gyrus during encoding does not impair associative memory performance

    No full text
    The left angular gyrus (AG) is thought to play a critical role in episodic retrieval and has been implicated in the recollection of specific details of prior episodes. Motivated by recent fMRI studies in which it was reported that elevated neural activity in left AG during study is predictive of subsequent associative memory, the present study investigated whether the region plays a causal role in associative memory encoding. Participants underwent online transcranial magnetic stimulation (TMS) while encoding word pairs prior to an associative memory test. We predicted that TMS to left AG during encoding would result in reduced subsequent memory accuracy, especially for estimates of recollection. The results did not support this prediction: estimates of both recollection and familiarity-driven recognition were essentially identical for words pairs encoded during TMS to left AG relative to a vertex control site. These results suggest that the left AG may not play a necessary role in associative memory encoding. TMS to left AG did however affect confidence for incorrect ‘intact’ judgments to rearranged pairs and incorrect ‘rearranged’ judgments to intact pairs. These findings suggest that the left AG supports encoding processes that contribute to aspects of subjective mnemonic experience
    corecore