149 research outputs found

    Target detection with a liquid crystal-based passive Stokes polarimeter

    No full text
    International audienceWe present an imaging system that measures the polarimetric state of the light coming from each point of a scene. This system, which determines the four components of the Stokes vector at each spatial location, is based on a liquid-crystal polarization modulator, which makes it possible to acquire fourdimensional Stokes parameter images at a standard video rate. We show that using such polarimetric images instead of simple intensity images can improve target detection and segmentation performance

    Automatic Red-Eye Removal based on Sclera and Skin Tone Detection

    Get PDF
    It is well-known that taking portrait photographs with a built in camera may create a red-eye effect. This effect is caused by the light entering the subject’s eye through the pupil and reflecting from the retina back to the sensor. These red eyes are probably one of the most important types of artifacts in portrait pictures. Many different techniques exist for removing these artifacts digitally after image capture. In most of the existing software tools, the user has to select the zone in which the red eye is located. The aim of our method is to automatically detect and correct the red eyes. Our algorithm detects the eye itself by finding the appropriate colors and shapes without input from the user. We use the basic knowledge that an eye is haracterized by its shape and the white color of the sclera. Combining this intuitive approach with the detection of “skin” around the eye, we obtain a higher success rate than most of the tools we tested. Moreover, our algorithm works for any type of skin tone. The main goal of this algorithm is to accurately remove red eyes from a picture, while avoiding false positives completely, which is the biggest problem of camera integrated algorithms or distributed software tools. At the same time, we want to keep the false negative rate as low as possible. We implemented this algorithm in a web-based application to allow people to correct their images online

    Automatic Red-Eye Removal based on Sclera and Skin Tone Detection

    Get PDF
    It is well-known that taking portrait photographs with a built in camera may create a red-eye effect. This effect is caused by the light entering the subject’s eye through the pupil and reflecting from the retina back to the sensor. These red eyes are probably one of the most important types of artifacts in portrait pictures. Many different techniques exist for removing these artifacts digitally after image capture. In most of the existing software tools, the user has to select the zone in which the red eye is located. The aim of our method is to automatically detect and correct the red eyes. Our algorithm detects the eye itself by finding the appropriate colors and shapes without input from the user. We use the basic knowledge that an eye is haracterized by its shape and the white color of the sclera. Combining this intuitive approach with the detection of “skin” around the eye, we obtain a higher success rate than most of the tools we tested. Moreover, our algorithm works for any type of skin tone. The main goal of this algorithm is to accurately remove red eyes from a picture, while avoiding false positives completely, which is the biggest problem of camera integrated algorithms or distributed software tools. At the same time, we want to keep the false negative rate as low as possible. We implemented this algorithm in a web-based application to allow people to correct their images online

    Automatic quantification of scapular and glenoid morphology from CT scans using deep learning.

    Get PDF
    OBJECTIVES To develop and validate an open-source deep learning model for automatically quantifying scapular and glenoid morphology using CT images of normal subjects and patients with glenohumeral osteoarthritis. MATERIALS AND METHODS First, we used deep learning to segment the scapula from CT images and then to identify the location of 13 landmarks on the scapula, 9 of them to establish a coordinate system unaffected by osteoarthritis-related changes, and the remaining 4 landmarks on the glenoid cavity to determine the glenoid size and orientation in this scapular coordinate system. The glenoid version, glenoid inclination, critical shoulder angle, glenopolar angle, glenoid height, and glenoid width were subsequently measured in this coordinate system. A 5-fold cross-validation was performed to evaluate the performance of this approach on 60 normal/non-osteoarthritic and 56 pathological/osteoarthritic scapulae. RESULTS The Dice similarity coefficient between manual and automatic scapular segmentations exceeded 0.97 in both normal and pathological cases. The average error in automatic scapular and glenoid landmark positioning ranged between 1 and 2.5 mm and was comparable between the automatic method and human raters. The automatic method provided acceptable estimates of glenoid version (R2 = 0.95), glenoid inclination (R2 = 0.93), critical shoulder angle (R2 = 0.95), glenopolar angle (R2 = 0.90), glenoid height (R2 = 0.88) and width (R2 = 0.94). However, a significant difference was found for glenoid inclination between manual and automatic measurements (p < 0.001). CONCLUSIONS This open-source deep learning model enables the automatic quantification of scapular and glenoid morphology from CT scans of patients with glenohumeral osteoarthritis, with sufficient accuracy for clinical use

    First observation of Bs -> D_{s2}^{*+} X mu nu decays

    Get PDF
    Using data collected with the LHCb detector in proton-proton collisions at a centre-of-mass energy of 7 TeV, the semileptonic decays Bs -> Ds+ X mu nu and Bs -> D0 K+ X mu nu are detected. Two structures are observed in the D0 K+ mass spectrum at masses consistent with the known D^+_{s1}(2536) and $D^{*+}_{s2}(2573) mesons. The measured branching fractions relative to the total Bs semileptonic rate are B(Bs -> D_{s2}^{*+} X mu nu)/B(Bs -> X mu nu)= (3.3\pm 1.0\pm 0.4)%, and B(Bs -> D_{s1}^+ X munu)/B(Bs -> X mu nu)= (5.4\pm 1.2\pm 0.5)%, where the first uncertainty is statistical and the second is systematic. This is the first observation of the D_{s2}^{*+} state in Bs decays; we also measure its mass and width.Comment: 8 pages 2 figures. Published in Physics Letters

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Full text link
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).Comment: 48 pages, 29 figures, Accepted for publication in Experimental Astronomy with minor editin

    Total hip replacement: increasing femoral offset improves functional outcome

    Get PDF
    INTRODUCTION: The aim of this study was to assess the independent effect of radiographic measures of implant position, relative to pre-operative anatomical assessment, on the functional outcome of total hip arthroplasty according to change in the Oxford hip score (OHS) 1 year post surgery. METHODS: A prospective cohort study was preformed to assess whether improvement in functional outcome (change in OHS at 1 year) and the relationship with femoral offset and length, and acetabular offset and height. After a power calculation 359 patients were recruited to the study and radiographic measures were performed by blinded observers. Regression analysis was used to assess the independent effect of the four radiographic measurements after adjusting for confounding variables. RESULTS: There was a significant (p < 0.001) decrease in acetabular offset [5.3 mm, 95 % confidence interval (CI) 4.4–6.2] and increase in femoral offset (6.1 mm, 95 % CI 5.4–6.8). Hence there was no significant change in overall offset. Femoral offset was the only radiographic measure to be achieved statistical significance (r = 0.198, 95 % CI 0.063–0.333, p = 0.004) in relation to clinical outcome, with increasing offset being associated with a greater improvement in the OHS. On combining femoral and acetabular offset increasing offset was associated with a greater improvement in the OHS (r = 0.10, 95 % CI 0.01–0.19, p = 0.04). CONCLUSION: This study supports the long-held biomechanical theory of medialisation of the acetabular component with compensatory increased femoral offset results in improved functional outcome

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Get PDF
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory. Athena is a versatile observatory designed to address the Hot and Energetic Universe science theme, as selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), X-IFU aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over a hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR (i.e. in the course of its preliminary definition phase, so-called B1), browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters, such as the instrument efficiency, spectral resolution, energy scale knowledge, count rate capability, non X-ray background and target of opportunity efficiency. Finally, we briefly discuss the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, touch on communication and outreach activities, the consortium organisation and the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with ESA member state contributions from Belgium, Czech Republic, Finland, Germany, Poland, Spain, Switzerland, with additional contributions from the United States and Japan.The French contribution to X-IFU is funded by CNES, CNRS and CEA. This work has been also supported by ASI (Italian Space Agency) through the Contract 2019-27-HH.0, and by the ESA (European Space Agency) Core Technology Program (CTP) Contract No. 4000114932/15/NL/BW and the AREMBES - ESA CTP No.4000116655/16/NL/BW. This publication is part of grant RTI2018-096686-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. This publication is part of grant RTI2018-096686-B-C21 and PID2020-115325GB-C31 funded by MCIN/AEI/10.13039/501100011033

    Vaccine breakthrough hypoxemic COVID-19 pneumonia in patients with auto-Abs neutralizing type I IFNs

    Full text link
    Life-threatening `breakthrough' cases of critical COVID-19 are attributed to poor or waning antibody response to the SARS- CoV-2 vaccine in individuals already at risk. Pre-existing autoantibodies (auto-Abs) neutralizing type I IFNs underlie at least 15% of critical COVID-19 pneumonia cases in unvaccinated individuals; however, their contribution to hypoxemic breakthrough cases in vaccinated people remains unknown. Here, we studied a cohort of 48 individuals ( age 20-86 years) who received 2 doses of an mRNA vaccine and developed a breakthrough infection with hypoxemic COVID-19 pneumonia 2 weeks to 4 months later. Antibody levels to the vaccine, neutralization of the virus, and auto- Abs to type I IFNs were measured in the plasma. Forty-two individuals had no known deficiency of B cell immunity and a normal antibody response to the vaccine. Among them, ten (24%) had auto-Abs neutralizing type I IFNs (aged 43-86 years). Eight of these ten patients had auto-Abs neutralizing both IFN-a2 and IFN-., while two neutralized IFN-omega only. No patient neutralized IFN-ss. Seven neutralized 10 ng/mL of type I IFNs, and three 100 pg/mL only. Seven patients neutralized SARS-CoV-2 D614G and the Delta variant (B.1.617.2) efficiently, while one patient neutralized Delta slightly less efficiently. Two of the three patients neutralizing only 100 pg/mL of type I IFNs neutralized both D61G and Delta less efficiently. Despite two mRNA vaccine inoculations and the presence of circulating antibodies capable of neutralizing SARS-CoV-2, auto-Abs neutralizing type I IFNs may underlie a significant proportion of hypoxemic COVID-19 pneumonia cases, highlighting the importance of this particularly vulnerable population
    • 

    corecore