213 research outputs found
Correlation between Gamma-Ray bursts and Gravitational Waves
The cosmological origin of -ray bursts (GRBs) is now commonly
accepted and, according to several models for the central engine, GRB sources
should also emit at the same time gravitational waves bursts (GWBs). We have
performed two correlation searches between the data of the resonant
gravitational wave detector AURIGA and GRB arrival times collected in the BATSE
4B catalog. No correlation was found and an upper limit \bbox{} on the averaged amplitude of gravitational waves
associated with -ray bursts has been set for the first time.Comment: 7 pages, 3 figures, submitted to Phys. Rev.
Wideband dual sphere detector of gravitational waves
We present the concept of a sensitive AND broadband resonant mass
gravitational wave detector. A massive sphere is suspended inside a second
hollow one. Short, high-finesse Fabry-Perot optical cavities read out the
differential displacements of the two spheres as their quadrupole modes are
excited. At cryogenic temperatures one approaches the Standard Quantum Limit
for broadband operation with reasonable choices for the cavity finesses and the
intracavity light power. A molybdenum detector of overall size of 2 m, would
reach spectral strain sensitivities of 2x10^-23/Sqrt{Hz} between 1000 Hz and
3000 Hz.Comment: 4 pages, 3 figures. Changed content. To appear in Phys. Rev. Let
The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
The CUORE experiment is the world's largest bolometric experiment. The
detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg.
CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso,
Italy, searching for the neutrinoless double beta decay of 130Te. A large
custom cryogen-free cryostat allows reaching and maintaining a base temperature
of about 10 mK, required for the optimal operation of the detector. This
apparatus has been designed in order to achieve a low noise environment, with
minimal contribution to the radioactive background for the experiment. In this
paper, we present an overview of the CUORE cryostat, together with a
description of all its sub-systems, focusing on the solutions identified to
satisfy the stringent requirements. We briefly illustrate the various phases of
the cryostat commissioning and highlight the relevant steps and milestones
achieved each time. Finally, we describe the successful cooldown of CUORE
Modeling freshwater quality scenarios with ecosystem-based adaptation in the headwaters of the Cantareira system, Brazil
Although hydrologic models provide hypothesis testing of complex
dynamics occurring at catchments, freshwater quality modeling is
still incipient at many subtropical headwaters. In Brazil, a few
modeling studies assess freshwater nutrients, limiting policies on
hydrologic ecosystem services. This paper aims to compare freshwater
quality scenarios under different land-use and land-cover (LULC) change,
one of them related to ecosystem-based adaptation (EbA), in
Brazilian headwaters. Using the spatially semi-distributed Soil and
Water Assessment Tool (SWAT) model, nitrate, total phosphorous (TP) and
sediment were modeled in catchments ranging from 7.2 to
1037 km2. These headwaters were eligible areas of the
Brazilian payment for ecosystem services (PES) projects in the
Cantareira water supply system, which had supplied water to
9 million people in the São Paulo metropolitan region (SPMR). We considered
SWAT modeling of three LULC scenarios: (i) recent past scenario
(S1), with historical LULC in 1990; (ii) current land-use
scenario (S2), with LULC for the period 2010–2015 with field
validation; and (iii) future land-use scenario with PES
(S2 + EbA). This latter scenario proposed forest cover
restoration through EbA following the river basin plan by
2035. These three LULC scenarios were tested with a selected record
of rainfall and evapotranspiration observed in 2006–2014, with the
occurrence of extreme droughts. To assess hydrologic services, we
proposed the hydrologic service index (HSI), as a new composite
metric comparing water pollution levels (WPL) for reference
catchments, related to the grey water footprint (greyWF) and water
yield. On the one hand, water quality simulations allowed for the
regionalization of greyWF at spatial scales under LULC
scenarios. According to the critical threshold, HSI identified areas
as less or more sustainable catchments. On the other hand,
conservation practices simulated through the S2 + EbA scenario
envisaged not only additional and viable best management practices (BMP),
but also preventive decision-making at the headwaters of water
supply systems.</p
Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
We report the results of a search for neutrinoless double-beta decay in a
9.8~kgyr exposure of Te using a bolometric detector array,
CUORE-0. The characteristic detector energy resolution and background level in
the region of interest are FWHM and ~counts/(keVkgyr), respectively. The
median 90%~C.L. lower-limit sensitivity of the experiment is and surpasses the sensitivity of previous searches. We find
no evidence for neutrinoless double-beta decay of Te and place a
Bayesian lower bound on the decay half-life, ~ at 90%~C.L. Combining CUORE-0 data with the 19.75~kgyr
exposure of Te from the Cuoricino experiment we obtain at 90%~C.L.~(Bayesian), the most stringent
limit to date on this half-life. Using a range of nuclear matrix element
estimates we interpret this as a limit on the effective Majorana neutrino mass,
-- .Comment: 6 pages, 5 figures, updated version as published in PR
CUORE-0 results and prospects for the CUORE experiment
With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV
(0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory
for Rare Events) experiment aims at searching for neutrinoless double beta
decay of 130Te with unprecedented sensitivity. Expected to start data taking in
2015, CUORE is currently in an advanced construction phase at LNGS. CUORE
projected neutrinoless double beta decay half-life sensitivity is 1.6E26 y at 1
sigma (9.5E25 y at the 90% confidence level), in five years of live time,
corresponding to an upper limit on the effective Majorana mass in the range
40-100 meV (50-130 meV). Further background rejection with auxiliary bolometric
detectors could improve CUORE sensitivity and competitiveness of bolometric
detectors towards a full analysis of the inverted neutrino mass hierarchy.
CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE
experiment. It consists of a single CUORE tower (52 TeO2 bolometers of 750 g
each, arranged in a 13 floor structure) constructed strictly following CUORE
recipes both for materials and assembly procedures. An experiment its own,
CUORE-0 is expected to reach a sensitivity to the neutrinoless double beta
decay half-life of 130Te around 3E24 y in one year of live time. We present an
update of the data, corresponding to an exposure of 18.1 kg y. An analysis of
the background indicates that the CUORE performance goal is satisfied while the
sensitivity goal is within reach.Comment: 10 pages, 3 figures, to appear in the proceedings of NEUTRINO 2014,
26th International Conference on Neutrino Physics and Astrophysics, 2-7 June
2014, held at Boston, Massachusetts, US
Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in Te with CUORE-0
We describe in detail the methods used to obtain the lower bound on the
lifetime of neutrinoless double-beta () decay in Te and
the associated limit on the effective Majorana mass of the neutrino using the
CUORE-0 detector. CUORE-0 is a bolometric detector array located at the
Laboratori Nazionali del Gran Sasso that was designed to validate the
background reduction techniques developed for CUORE, a next-generation
experiment scheduled to come online in 2016. CUORE-0 is also a competitive
decay search in its own right and functions as a platform to
further develop the analysis tools and procedures to be used in CUORE. These
include data collection, event selection and processing, as well as an
evaluation of signal efficiency. In particular, we describe the amplitude
evaluation, thermal gain stabilization, energy calibration methods, and the
analysis event selection used to create our final decay search
spectrum. We define our high level analysis procedures, with emphasis on the
new insights gained and challenges encountered. We outline in detail our
fitting methods near the hypothesized decay peak and catalog
the main sources of systematic uncertainty. Finally, we derive the
decay half-life limits previously reported for CUORE-0,
yr, and in combination with the Cuoricino
limit, yr.Comment: 18 pages, 18 figures. (Version 3 reflects only minor changes to the
text. Few additional details, no major content changes.
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will
search for neutrinoless double beta decay of Te. With 741 kg of TeO
crystals and an excellent energy resolution of 5 keV (0.2%) at the region of
interest, CUORE will be one of the most competitive neutrinoless double beta
decay experiments on the horizon. With five years of live time, CUORE projected
neutrinoless double beta decay half-life sensitivity is y
at ( y at the 90% confidence level), which
corresponds to an upper limit on the effective Majorana mass in the range
40--100 meV (50--130 meV). Further background rejection with auxiliary light
detector can significantly improve the search sensitivity and competitiveness
of bolometric detectors to fully explore the inverted neutrino mass hierarchy
with Te and possibly other double beta decay candidate nuclei.Comment: Submitted to the Proceedings of TAUP 2013 Conferenc
Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments
CUORE is a 741 kg array of TeO2 bolometers for the search of neutrinoless
double beta decay of 130Te. The detector is being constructed at the Laboratori
Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If
the target background of 0.01 counts/keV/kg/y will be reached, in five years of
data taking CUORE will have a 1 sigma half life sensitivity of 10E26 y. CUORE-0
is a smaller experiment constructed to test and demonstrate the performances
expected for CUORE. The detector is a single tower of 52 CUORE-like bolometers
that started taking data in spring 2013. The status and perspectives of CUORE
will be discussed, and the first CUORE-0 data will be presented.Comment: 7 pages, 4 figures, to be published in the proceedings of ICHEP 2014,
37th International Conference on High Energy Physics, Valencia (Spain) 2-9
July 201
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes
for physics beyond the Standard Model, providing unique information on the
nature of neutrinos. In this paper we review the status and outlook for
bolometric 0nubb decay searches. We summarize recent advances in background
suppression demonstrated using bolometers with simultaneous readout of heat and
light signals. We simulate several configurations of a future CUORE-like
bolometer array which would utilize these improvements and present the
sensitivity reach of a hypothetical next-generation bolometric 0nubb
experiment. We demonstrate that a bolometric experiment with the isotope mass
of about 1 ton is capable of reaching the sensitivity to the effective Majorana
neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the
so-called inverted neutrino mass hierarchy region. We highlight the main
challenges and identify priorities for an R&D program addressing them.Comment: 22 pages, 15 figures, submitted to EPJ
- …