136 research outputs found

    Ambient measurements of aromatic and oxidized VOCs by PTR-MS and GC-MS : intercomparison between four instruments in a boreal forest in Finland

    Get PDF
    Proton transfer reaction mass spectrometry (PTR-MS) and gas chromatography mass spectrometry GC-MS) are commonly used methods for automated in situ measurements of various volatile organic compounds (VOCs) in the atmosphere. In order to investigate the reliability of such measurements, we operated four automated analyzers using their normal field measurement protocol side by side at a boreal forest site. We measured methanol, acetaldehyde, acetone, benzene and toluene by two PTR-MS and two GC-MS instruments. The measurements were conducted in southern Finland between 13 April and 14 May 2012. This paper presents correlations and biases between the concentrations measured using the four instruments. A very good correlation was found for benzene and acetone measurements between all instruments (the mean R value was 0.88 for both compounds), while for acetaldehyde and toluene the correlation was weaker (with a mean R value of 0.50 and 0.62, respectively). For some compounds, notably for methanol, there were considerable systematic differences in the mixing ratios measured by the different instruments, despite the very good correlation between the instruments (mean R = 0.90). The systematic difference manifests as a difference in the linear regression slope between measurements conducted between instruments, rather than as an offset. This mismatch indicates that the systematic uncertainty in the sensitivity of a given instrument can lead to an uncertainty of 50-100% in the methanol emissions measured by commonly used methods.Peer reviewe

    Pharmaceutical Formulation Facilities as Sources of Opioids and Other Pharmaceuticals to Wastewater Treatment Plant Effluents

    Get PDF
    Facilities involved in the manufacture of pharmaceutical products are an under-investigated source of pharmaceuticals to the environment. Between 2004 and 2009, 35 to 38 effluent samples were collected from each of three wastewater treatment plants (WWTPs) in New York and analyzed for seven pharmaceuticals including opioids and muscle relaxants. Two WWTPs (NY2 and NY3) receive substantial flows (>20% of plant flow) from pharmaceutical formulation facilities (PFF) and one (NY1) receives no PFF flow. Samples of effluents from 23 WWTPs across the United States were analyzed once for these pharmaceuticals as part of a national survey. Maximum pharmaceutical effluent concentrations for the national survey and NY1 effluent samples were generally <1 μg/L. Four pharmaceuticals (methadone, oxycodone, butalbital, and metaxalone) in samples of NY3 effluent had median concentrations ranging from 3.4 to >400 μg/L. Maximum concentrations of oxycodone (1700 μg/L) and metaxalone (3800 μg/L) in samples from NY3 effluent exceeded 1000 μg/L. Three pharmaceuticals (butalbital, carisoprodol, and oxycodone) in samples of NY2 effluent had median concentrations ranging from 2 to 11 μg/L. These findings suggest that current manufacturing practices at these PFFs can result in pharmaceuticals concentrations from 10 to 1000 times higher than those typically found in WWTP effluents

    A cluster randomised trial of educational messages to improve the primary care of diabetes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Regular laboratory test monitoring of patient parameters offers a route for improving the quality of chronic disease care. We evaluated the effects of brief educational messages attached to laboratory test reports on diabetes care.</p> <p>Methods</p> <p>A programme of cluster randomised controlled trials was set in primary care practices in one primary care trust in England. Participants were the primary care practices' constituent healthcare professionals and patients with diabetes. Interventions comprised brief educational messages added to paper and electronic primary care practice laboratory test reports and introduced over two phases. Phase one messages, attached to Haemoglobin A1c (HbA1c) reports, targeted glycaemic and cholesterol control. Phase two messages, attached to albumin:creatinine ratio (ACR) reports, targeted blood pressure (BP) control, and foot inspection. Main outcome measures comprised practice mean HbA1c and cholesterol levels, diastolic and systolic BP, and proportions of patients having undergone foot inspections.</p> <p>Results</p> <p>Initially, 35 out of 37 eligible practices participated. Outcome data were available for a total of 8,690 patients with diabetes from 32 practices. The BP message produced a statistically significant reduction in diastolic BP (-0.62 mmHg; 95% confidence interval -0.82 to -0.42 mmHg) but not systolic BP (-0.06 mmHg, -0.42 to 0.30 mmHg) and increased the odds of achieving target BP control (odds ratio 1.05; 1.00, 1.10). The foot inspection message increased the likelihood of a recorded foot inspection (incidence rate ratio 1.26; 1.18 to 1.36). The glycaemic control message had no effect on mean HbA1c (increase 0.01%; -0.03 to 0.04) despite increasing the odds of a change in likelihood of HbA1c tests being ordered (OR 1.06; 1.01, 1.11). The cholesterol message had no effect (decrease 0.01 mmol/l, -0.04 to 0.05).</p> <p>Conclusions</p> <p>Three out of four interventions improved intermediate outcomes or process of diabetes care. The diastolic BP reduction approximates to relative reductions in mortality of 3% to 5% in stroke and 3% to 4% in ischaemic heart disease over 10 years. The lack of effect for other outcomes may, in part, be explained by difficulties in bringing about further improvements beyond certain thresholds of clinical performance.</p> <p>Trial Registration</p> <p>Current Controlled Trials, <a href="http://www.controlled-trials.com/ISRCTN2186314">ISRCTN2186314</a>.</p

    Molecular and life-history effects of a natural toxin on herbivorous and non-target soil arthropods

    Get PDF
    Natural toxins, such as isothiocyanate (ITC), are harmful secondary metabolites produced by plants. Many natural toxins occur in commercial crops, yet their possible negative repercussions on especially non-target soil organisms are largely unknown. This study examined life-history and gene transcriptional responses to 2-phenylethyl ITC on two soil arthropod species: Folsomia candida and Protaphorura fimata. To that end the standardized ISO guideline for ecotoxicological tests and a microarray for F. candida were used. The dissipation of 2-phenylethyl ITC in natural soil was investigated using GC-MS/MS for quantification. Half-lives, tested at four concentration levels in natural soil, were on average 16 h with biodegradation as the plausible main removal process. Regardless, toxic effects on reproduction were shown for F. candida and P. fimata, with EC50 values of around 11.5 nmol/g soil illustrating the toxic character of this compound. Gene expression profiles revealed the importance of fatty acid metabolism at low exposure concentrations (EC10), which is associated with the lipophilic nature of 2-phenylethyl ITC. At higher concentrations (EC50) gene expression became more ubiquitous with over-expression of especially stress-related genes and sugar metabolism. The regulation of a gene encoding a precursor of follistatin, furthermore, implied the inhibition of reproduction and may be an important molecular target that can be linked to the observed adverse effect of life-history traits

    ACTRIS non-methane hydrocarbon intercomparison experiment in Europe to support WMO GAW and EMEP observation networks

    Get PDF
    The performance of 18 European institutions involved in long-term non-methane hydrocarbon (NMHC) measurements in ambient air within the framework of the Global Atmosphere Watch (GAW) and the European Monitoring and Evaluation Programme (EMEP) was assessed with respect to data quality objectives (DQOs) of ACTRIS (Aerosols, Clouds, and Trace gases Research InfraStructure Network) and GAW. Compared to previous intercomparison studies the DQOs define a novel approach to assess and ensure a high quality of the measurements. Having already been adopted by GAW, the ACTRIS DQOs are demanding with deviations to a reference value of less than 5% and a repeatability of better than 2% for NMHC mole fractions above 0.1 nmol mol(-1). The participants of the intercomparison analysed two dry gas mixtures in pressurised cylinders, a 30-component NMHC mixture in nitrogen (NMHC_N-2 /at approximately 1 nmol mol(-1) and a whole air sample (NMHC_air), following a standardised operation procedure including zero-and calibration gas measurements. Furthermore, participants had to report details on their instruments and assess their measurement uncertainties. The NMHCs were analysed either by gas chromatography-flame ionisation detection (GC-FID) or by gas chromatography-mass spectrometry (GC-MS). For the NMHC_N-2 measurements, 62% of the reported values were within the 5% deviation class corresponding to the ACTRIS DQOs. For NMHC_air, generally more frequent and larger deviations to the assigned values were observed, with 50% of the reported values within the 5% deviation class. Important contributors to the poorer performance in NMHC_air compared to NMHC_N-2 were a more complex matrix and a larger span of NMHC mole fractions (0.03-2.5 nmol mol(-1)). The performance of the participating laboratories were affected by the different measurement procedures such as the usage of a two-step vs. a one-step calibration, breakthroughs of C-2-C-3 hydrocarbons in the focussing trap, blank values in zero-gas measurements (especially for those systems using a Nafion (R) Dryer), adsorptive losses of aromatic compounds, and insufficient chromatographic separation.Peer reviewe
    corecore