11 research outputs found

    FACTOR ANALYSIS OF SPRINT PHASES ON THE SPEED CURVE OF THE 100M DASH

    Get PDF
    Previous studies have indicated that the speed curve of the 100m dash consists of some distinct phases which can be used to analyze an athlete's performance. The purpose of this study was to introduce a method using a portable computer as a device for the measurement of sprint time and the illustration of the speed curve, and to clarify a simple model of sprint phases on the factor structure. Based on the data of 133 participants, principal factor solution was given to the correlation matrix, and varimax rotation was applied to simplify the factorial structure of sprint phases. Finally, two factors were extracted and interpreted. It is suggested that this method is useful for measurement and evaluation in the 100m dash, and that a simple model of sprint phases may be explained by these two factors. These findings are important in predicting the ability of 100m sprinters and in considering coaching methods in terms of technique, training, strategy, etc

    A case of small cell gastric carcinoma with an adenocarcinoma component operated curatively.

    Get PDF
    We present a case of a primary advanced gastric tumor that was composed of 2 different pathological components: small cell carcinoma and moderately-differentiated adenocarcinoma. The patient was still alive four years after the surgery was performed, without recurrence. A large part of the tumor consisted of a diffuse sheet of small cell carcinoma, which transitioned into another small portion consisting of moderately-differentiated tubular adenocarcinoma components. Therefore, this case raised the possibility that small cell gastric carcinoma may originate from totipotential stem cells of the stomach. Although small cell carcinoma progresses aggressively, and patients with it have an extremely poor prognosis, this patient recovered uneventfully after the surgical resection, and has remained in good health, without any recurrences.</p

    Biological Evaluation of the Effect of Root Canal Sealers Using a Rat Model

    No full text
    Gutta-percha points and root canal sealers have been used for decades in endodontics for root canal obturation. With techniques such as single cone methods, the amount of sealer is larger, making their properties more critical. However, relatively few reports have comprehensively evaluated their biological effects. To this end, we evaluated three types of sealers, zinc oxide-fatty acid-, bio-glass- and methacrylate resin-containing sealers were considered. Their biological effects were evaluated using a rat subcutaneous implantation model. Each sealer was loaded inside a Teflon tube and implanted subcutaneously in the backs of rats. Inflammatory cells were observed around all samples 7 days after implantation and reduced after 28 days. Our results revealed that all samples were in contact with the subcutaneous tissue surrounding the sealer. Additionally, Ca and P accumulation was observed in only the bio-glass-containing sealer. Furthermore, each of the three sealers exhibited unique immune and inflammatory modulatory effects. In particular, bio-glass and methacrylate resin sealers were found to induce variable gene expression in adjacent subcutaneous tissues related to angiogenesis, wound healing, muscle tissue, and surrounding subcutaneous tissue. These results may help to understand the biological impacts of root canal sealers on surrounding biological tissues, guiding future research and comparisons with new generations of materials

    原子核内の古典的流束

    Get PDF
    Objective To present results of the Kyoto Global Consensus Meeting, which was convened to develop global consensus on (1) classification of chronic gastritis and duodenitis, (2) clinical distinction of dyspepsia caused by Helicobacter pylori from functional dyspepsia, (3) appropriate diagnostic assessment of gastritis and (4) when, whom and how to treat H. pylori gastritis. Design Twenty-three clinical questions addressing the above-mentioned four domains were drafted for which expert panels were asked to formulate relevant statements. A Delphi method using an anonymous electronic system was adopted to develop the consensus, the level of which was predefined as â\u89¥80%. Final modifications of clinical questions and consensus were achieved at the face-to-face meeting in Kyoto. Results All 24 statements for 22 clinical questions after extensive modifications and omission of one clinical question were achieved with a consensus level of >80%. To better organise classification of gastritis and duodenitis based on aetiology, a new classification of gastritis and duodenitis is recommended for the 11th international classification. A new category of H. pyloriassociated dyspepsia together with a diagnostic algorithm was proposed. The adoption of grading systems for gastric cancer risk stratification, and modern image-enhancing endoscopy for the diagnosis of gastritis, were recommended. Treatment to eradicate H. pylori infection before preneoplastic changes develop, if feasible, was recommended to minimise the risk of more serious complications of the infection. Conclusions A global consensus for gastritis was developed for the first time, which will be the basis for an international classification system and for further research on the subject

    Abstracts Of Selected Papers Presented At The 75Th General Meeting Of The Japanese Society Of Gastroenterology March 27–29, 1989 — Yokohama, Japan

    No full text

    International Large Detector: Interim Design Report

    No full text
    The ILD detector is proposed for an electron-positron collider with collision centre-of-mass energies from 90~\GeV~to about 1~\TeV. It has been developed over the last 10 years by an international team of scientists with the goal to design and eventually propose a fully integrated detector, primarily for the International Linear Collider, ILC. In this report the fundamental ideas and concepts behind the ILD detector are discussed and the technologies needed for the realisation of the detector are reviewed. The document starts with a short review of the science goals of the ILC, and how the goals can be achieved today with the detector technologies at hand. After a discussion of the ILC and the environment in which the experiment will take place, the detector is described in more detail, including the status of the development of the technologies foreseen for each subdetector. The integration of the different sub-systems into an integrated detector is discussed, as is the interface between the detector and the collider. This is followed by a concise summary of the benchmarking which has been performed in order to find an optimal balance between performance and cost. To the end the costing methodology used by ILD is presented, and an updated cost estimate for the detector is presented. The report closes with a summary of the current status and of planned future actions
    corecore