344 research outputs found

    Cardiac-respiratory self-gated cine ultra-short echo time (UTE) cardiovascular magnetic resonance for assessment of functional cardiac parameters at high magnetic fields

    Full text link
    Background: To overcome flow and electrocardiogram-trigger artifacts in cardiovascular magnetic resonance (CMR), we have implemented a cardiac and respiratory self-gated cine ultra-short echo time (UTE) sequence. We have assessed its performance in healthy mice by comparing the results with those obtained with a self-gated cine fast low angle shot (FLASH) sequence and with echocardiography. Methods: 2D self-gated cine UTE (TE/TR = 314 μs/6.2 ms, resolution: 129 × 129 μm, scan time per slice: 5 min 5 sec) and self-gated cine FLASH (TE/TR = 3 ms/6.2 ms, resolution: 129 × 129 μm, scan time per slice: 4 min 49 sec) images were acquired at 9.4 T. Volume of the left and right ventricular (LV, RV) myocardium as well as the end-diastolic and -systolic volume was segmented manually in MR images and myocardial mass, stroke volume (SV), ejection fraction (EF) and cardiac output (CO) were determined. Statistical differences were analyzed by using Student t test and Bland-Altman analyses. Results: Self-gated cine UTE provided high quality images with high contrast-to-noise ratio (CNR) also for the RV myocardium (CNRblood-myocardium = 25.5 ± 7.8). Compared to cine FLASH, susceptibility, motion, and flow artifacts were considerably reduced due to the short TE of 314 μs. The aortic valve was clearly discernible over the entire cardiac cycle. Myocardial mass, SV, EF and CO determined by self-gated UTE were identical to the values measured with self-gated FLASH and showed good agreement to the results obtained by echocardiography. Conclusions: Self-gated UTE allows for robust measurement of cardiac parameters of diagnostic interest. Image quality is superior to self-gated FLASH, rendering the method a powerful alternative for the assessment of cardiac function at high magnetic fields.</p

    Transthoracic echocardiography reference values in juvenile and adult 129/Sv mice

    Get PDF
    Background In the recent years, the use of Doppler-echocardiography has become a standard non-invasive technique in the analysis of cardiac malformations in genetically modified mice. Therefore, normal values have to be established for the most commonly used inbred strains in whose genetic background those mutations are generated. Here we provide reference values for transthoracic echocardiography measurements in juvenile (3 weeks) and adult (8 weeks) 129/Sv mice. Methods Echocardiographic measurements were performed using B-mode, M-mode and Doppler-mode in 15 juvenile (3 weeks) and 15 adult (8 weeks) mice, during isoflurane anesthesia. M-mode measurements variability of left ventricle (LV) was determined. Results Several echocardiographic measurements significantly differ between juvenile and adult mice. Most of these measurements are related with cardiac dimensions. All B-mode measurements were different between juveniles and adults (higher in the adults), except for fractional area change (FAC). Ejection fraction (EF) and fractional shortening (FS), calculated from M-mode parameters, do not differ between juvenile and adult mice. Stroke volume (SV) and cardiac output (CO) were significantly different between juvenile and adult mice. SV was 31.93 ± 8.67 μl in juveniles vs 70.61 ± 24.66 μl in adults, ρ < 0.001. CO was 12.06 ± 4.05 ml/min in juveniles vs 29.71 ± 10.13 ml/min in adults, ρ < 0.001. No difference was found in mitral valve (MV) and tricuspid valve (TV) related parameters between juvenile and adult mice. It was demonstrated that variability of M-mode measurements of LV is minimal. Conclusions This study suggests that differences in cardiac dimensions, as wells as in pulmonary and aorta outflow parameters, were found between juvenile and adult mice. However, mitral and tricuspid inflow parameters seem to be similar between 3 weeks and 8 weeks mice. The reference values established in this study would contribute as a basis to future studies in post-natal cardiovascular development and diagnosing cardiovascular disorders in genetically modified mouse mutant lines.Peer Reviewe

    Tractatus de referendariis et eorum officio in legendis actis

    Get PDF

    Excessive Daytime Sleepiness Is a Common Symptom in Fabry Disease

    Get PDF
    Fabry disease (FD) is an X-linked lysosomal storage disorder characterized by a deficient activity of the enzyme α-galactosidase A, resulting in a vasculopathic involvement of various organ systems, e.g. cerebral structures. Marked cerebral vasculopathy with subsequent white matter lesions (WML) are a frequent finding in FD patients. Recent studies discussed an association between cerebral white matter changes and sleep-related disturbances of breathing, which may lead to excessive daytime sleepiness (EDS). A 56-year-old Caucasian female FD patient with EDS was admitted to our sleep laboratory. Overnight polysomnography showed a Cheyne-Stokes respiration pattern with significant O2 desaturation. MR imaging revealed confluent WML including the brain stem, but no renal or cardiac involvement. We then evaluated the clinical data of 49 genetically proven FD patients (27 males; mean age 43 years) from our FD centre. With a frequency of 68%, EDS exceeds the prevalence of other common symptoms of FD (angiokeratomas 61%; acroparaesthesia 51%; renal involvement 29%; cardiac involvement 27%), and the prevalence of chronic fatigue (48%). EDS was independently associated with the physical component summary of the SF-36 data (corrected R2 = −0.323, p < 0.001). EDS and age explained a quarter of variance in mental component summary (corrected R2 = −0.253, p < 0.001). We conclude that EDS is a common and underdiagnosed symptom in FD patients, accompanied by a significant impact on quality of life. EDS might be caused by central breathing disorders due to an affection of brain regions associated with respiratory control in FD

    G-CSF/SCF reduces inducible arrhythmias in the infarcted heart potentially via increased connexin43 expression and arteriogenesis

    Get PDF
    Granulocyte colony-stimulating factor (G-CSF), alone or in combination with stem cell factor (SCF), can improve hemodynamic cardiac function after myocardial infarction. Apart from impairing the pump function, myocardial infarction causes an enhanced vulnerability to ventricular arrhythmias. Therefore, we investigated the electrophysiological effects of G-CSF/SCF and the underlying cellular events in a murine infarction model

    Оценка негосударственной поддержки малого и среднего бизнеса как фактора конкурентоспособности компании (на примере стран Таможенного союза)

    Get PDF
    Объектом исследования является деятельность торгово-промышленной палаты в России и в странах Таможенного союза ЕАЭС. Предметом исследования являются возможности торгово-промышленной палаты в России и в странах Таможенного союза ЕАЭС. Цель работы – обосновать, что негосударственная поддержка является фактором конкурентоспособности предприятий малого и среднего бизнеса в странах Таможенного союза ЕАЭС. Актуальность работы обусловлена значимостью торгово-промышленной палаты в развитии, как национальной экономики, так и достижении конкурентоспособности предприятий МСБ – участников внешнеэкономической деятельности.The object of research is the activity of the Chamber of Commerce and Industry of the Russian Federation and the countries of the Eurasian Economic Union. The subject of research is opportunities of Chamber of Commerce and Industry of the Russian Federation and the countries of the Eurasian Economic Union. The purpose of work - to prove that the non-governmental support is a factor in the competitiveness of small and medium-sized businesses in the countries of the Eurasian Economic Union. Timeliness of the work is due to the significance of the Chamber of Commerce and Industry in the development of business, as the national economy and achieving competitiveness of SMEs - participants of international economic activity
    corecore