308 research outputs found

    Ovarian reserve and anti-Mullerian hormone (AMH) in mothers of dizygotic twins

    Get PDF
    This study aimed to explore if natural dizygotic (DZ) twinning is associated with earlier menopause and lower anti-Mullerian hormone (AMH) values. We investigated if advanced biological reproductive aging, which can be responsible for the multiple follicle growth in familial twinning, is similar to mechanisms that occur in normal ovarian aging, reflected by earlier menopause in mothers of DZ twins and lower levels of AMH. A total of 16 mothers of DZ twins enrolled with the Netherlands Twin Register (average age at first assessment: 35.9 +/- 3.0 years) and 14 control mothers (35.1 +/- 3 years) took part in a prospective study. Fifteen years after entry into the study, which included follicle-stimulating hormone (FSH) assessment, AMH was measured in stored serum samples and menopause status was evaluated. Average AMH levels were not significantly different between DZ twin mothers and controls (2.1 +/- 2.4 mu g/L vs. 1.9 +/- 1.9 mu g/L). Among the 16 mothers of twins, 7 had an elevated (FSH) value over 10 U/L at first assessment. Their AMH levels were lower than the nine twin mothers with normal FSH values: 0.6 +/- 0.4 versus 3.4 +/- 2.6 mu g/L (p = .01). Of the mothers of twins, eight mothers had entered menopause at the second assessment compared with only one control mother (p = .07). Thus, slightly more DZ mothers were in menopause than the control mothers, although this difference was not significant. The subgroup of DZ twin mothers who had an increased FSH concentration 15 years ago had a limited ovarian reserve as reflected by lower AMH levels. These data indicate that advanced ovarian aging can be a feature in familial DZ twinning, particularly with elevated early follicular phase FSH

    Algebraic manipulation Assistant for Propositional Logic and Predicate Calculus: Improvements

    Get PDF
    Teema lühikirjeldus Lausearvutuse ja predikaatarvutuse valemite teisendamise õpiprogrammi programmeeris 2003. aastal Vahur Vaiksoo oma bakalaureusetöö raames. Seda programmi kasutatakse Tartu Ülikoolis üliõpilastele lausearvutuse ja predikaatarvutuse valemite teisendamise õpetamisel ja nende teadmiste kontrollimisel. Selleks, et programmi kasutajatel oleks lihtsam valemite teisendamist õppida, võiks programm võimaldada nõu küsimist järgmise sammu tegemiseks vastavalt lahendatavale ülesandetüübile. Seda funktsionaalsust peab olema võimalik välja lülitada vastavalt kasutusviisile (harjutamine, kontrolltöö). Programm salvestab praegu lahendused ainult valemite jadana. Lahenduste loetavuse parandamiseks ja võimalikuks automaatseks analüüsiks oleks vaja salvestada ka üliõpilase poolt teisendamiseks valitud valemi osa ja reeglipõhise lahendusrežiimi puhul kasutatud teisendusreegel. Hetkel on programm programmeeritud selliselt, et kõik tekstid, mida programmi kasutaja näeb, on ühes (eesti) keeles. Programmi laiemaks kasutamiseks oleks vaja võimalust keeli lisada ja valida. Eeldatavad tulemused •Programmile lisatakse automaatlahendaja ja võimalus saada nõuannet järgmise sammu tegemiseks. •Igal sammul salvestatakse ka teisendamiseks valitud valemi osa ja teisendusreegel •Programmi koodi on muudetud selliseks, et oleks võimalik sellele tõlkefaile kirjutada. Programmisiseselt saab valida, millist keelt programm kasutab. •On koostatud juhendid programmi tõlkijatele tõlkefailide loomiseks.Thesis description In 2003 Vahur Vaiksoo created the program for algebraic manipulation of propositional logic and predicate calculus for his thesis. It is currently being used in the University of Tartu for teaching propositional and predicate calculus. In addition it is being used to test the acquired knowledge of the students. To make it easier to learn the transformation of formulas, some additions have to be made for the program. One of the additions is an automatic solver that would also give hints to the user for making the next step towards solving the task. Since the program is also used in tests, this functionality must be switched off for individual tasks when needed. The program is currently saving logs as a list of successfully transformed formulas. To make it easier to analyse the student's solutions, it is needed to save additional information about every transformation step. For instance, the subformulas that were selected and what kind of rule was used in the rule-based task. All of the texts that are shown to the user are hardcoded in Estonian language. To make the program more widely usable, it is needed to add functionality to allow changing the program's language. Expected results •An automatic solver is added to the program. It will give hints to the user about the next transofrmation step when he/she asks for it. •On every transformation step the selected subformula and used rule are saved into the log. •The functionality to write language files are added to the program. The user can select a language file to change the program's language. •The instructions file for creating the language files is written for possible translators of the program

    Safety Margins for Geometrical Uncertainties in Radiotherapy

    Get PDF
    Cancer is the unrestricted growth of cells in an organism, which can eventually destroy organs that are needed for survival of the organism. Throughout human history, cancer has been one of the major medical causes of death. At the moment, there are about 840.000 cancer fatalities in Europe per year. It is estimated that in the westem world approximately 1 in 3 people will develop some kind of tumor during their lifetime, and more than 1 in 5 will die of it. Although significant progress has been achieved in the fight against cancer in the last decades, still about half of the cancers cannot be cured. Currently, the three main therapies for cancer are surgery (removing the tumor), radiotherapy (killing the tumor cells with radiation), and chemotherapy (the use of anti-cancer mugs). The first two are especially used for tumors that are well localized. Surgety is straightforward but catmot always be applied, for instance when the tumor is localized in or close to a vital organ. Futthermore, invisible, microscopic extensions of the tumor might be trtissed. In radiotherapy, those tumor extensions can be treated more easily. Moreover, this therapy may be less demanding on the patient and hospitalization is usually not necessaty. When microscopic tumor cells have spread from the primary tumor site to different parts of the body, chemotherapy can be applied. The blood circulation is used to transpoti the drugs are transported through the body. In many cases, the difterent therapies are combined to improve the treatment outcome. Radiotherapy is used for about half of all cancer patients. With radiotherapy, ionizing radiation in the fotm of high energy photons, electrons or protons is aimed at the tumor. These particles deposit some of their energy in the tumor cells, which can cause ionization of DNA or surrounding molecules. This can induce irreparable genetic damages in the tumor cells that either kill the cell directly or result in the socalled apoptosis, i.e. cellular suicide. However, since radiation may kill healthy cells as well, one has to be careful to deliver the radiation dose in the right place. Basically, there are two ways the radiation can be delivered: by brachytherapy or by external beam radiotherapy

    An in silico Trial of X-rays vs Carbon Ions in Lung Cancer Radiosurgery

    Get PDF

    Spacecraft thermal control design data

    Full text link
    This paper shows the actual state of a compilation work on Thermal Control Design Data being done at Madrid (Lamf-ETSIA) under several ESTEC contracts, introducing a Handbook already issued, its additions and updatings

    High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging

    Get PDF
    Purpose: To investigate in three institutions, The Netherlands Cancer Institute (Antoni van Leeuwenhoek Huis [AvL]), Dr. Daniel den Hoed Cancer Center (DDHC), and Dr. Bernard Verbeeten Institute (BVI), how much the patient setup accuracy for irradiation of prostate cancer can be improved by an offline setup verification and correction procedure, using portal imaging. Methods and Materials: The verification procedure consisted of two stages. During the first stage, setup deviations were measured during a number (N(max)) of consecutive initial treatment sessions. The length of the average three dimensional (3D) setup deviation vector was compared with an action level for corrections, which shrunk with the number of setup measurements. After a correction was applied, N(max) measurements had to be performed again. Each institution chose different values for the initial action level (6, 9, and 10 mm) and N(max) (2 and 4). The choice of these parameters was based on a simulation of the procedure, using as input preestimated values of random and systematic deviations in each institution. During the second stage of the procedure, with weekly setup measurements, the AvL used a different criterion ('outlier detection') for corrective actions than the DDHC and the BVI ('sliding average'). After each correction the first stage of the procedure was restarted. The procedure was tested for 151 patients (62 in AvL, 47 in DDHC, and 42 in BVI) treated for prostate carcinoma. Treatment techniques and portal image acquisition and analysis were different in each institution. Results: The actual distributions of random and systematic deviations without corrections were estimated by eliminating the effect of the corrections. The percentage of mean (systematic) 3D deviations larger than 5 mm was 26% for the AvL and the DDHC, and 36% for the BVI. The setup accuracy after application of the procedure was considerably improved (percentage of mean 3D deviations larger than 5 mm was 1.6% in the AvL and 0% in the DDHC and BVI), in agreement with the results of the simulation. The number of corrections (about 0.7 on the average per patient) was not larger than predicted. Conclusion: The verification procedure appeared to be feasible in the three institutions and enabled a significant reduction of mean 3D setup deviations. The computer simulation of the procedure proved to be a useful tool, because it enabled an accurate prediction of the setup accuracy and the required number of corrections

    MR-ONLY as a reference image in verifying positioning in radiotherapy

    Get PDF
    Introdução: Os sistemas de planeamento utilizam a informação das densidades eletrónicas, necessárias para o cálculo de dose provenientes da TC. Uma tendência recente é o uso da RM como única modalidade, usando as imagens de RM para criar uma TC sintética. Um fluxo de trabalho no qual todas as etapas pré-tratamento são realizadas na RM é favorável. O objetivo do estudo é validar a técnica MR-Only como imagem de referência na verificação do posicionamento em Radioterapia. Metodologia: Foram incluídos 13 doentes com tumor cerebral e 15 doentes com tumor retal, seguidos no Serviço de Radioterapia do Centro Clínico Champalimaud, de outubro de 2019 a junho de 2020. Com base no registo automático de 80 CBCT comparou-se os desvios entre as imagens da TC de planeamento e da TC sintética (MR-Only). Resultados: No registo das imagens do reto, a variação que se obteve foi inferior a 1,4mm longitudinal, 1mm lateral e vertical. A variação nas translações foi de -0,2±0,3mm lateral, -0,3±0,4mm vertical e de -0,4±0,7mm longitudinal. As rotações foram inferiores a 0,4º, sendo a variação verificada 0,0±0,2º pitch, 0,0±0,1º yaw e de 0,0±0,1º roll. No cérebro foi inferior a 1,3mm longitudinal, a 0,6mm vertical e a 0,4mm lateral. A variação verificada foi de -0,2±0,2mm lateral, -0,3±0,2mm vertical e de -0,4±0,5mm longitudinal. Nas rotações, obteve-se uma rotação máxima de 0,3º, sendo a variação verificada -0,2±0,1º pitch, 0,1±0,1º yaw e de 0,0±0,1º roll. Conclusão: Foi validado o registo da imagem da TC sintética com a imagem de verificação CBCT. Os desvios encontrados nos registos entre a TC de planeamento e a TC sintética da RM sugerem que é justificado o uso da técnica MR-Only como imagem de referência.ABSTRACT - Introduction: The planning systems use the information of the electronic densities, needed for the calculation of the dose from the CT. A recent trend is the use of MR as the only modality, using the MR image to create a synthetic CT. A workflow in which all pre-treatment steps are performed at the MR is favorable. The objective of this study is to validate the MR-Only technique as the reference image in the verification of positioning in Radiotherapy. Materials and Methods: 13 patients with a brain tumor and 15 patients with a rectal tumor followed at the Radiotherapy Unit of the Champalimaud Clinical Center, from October 2019 to June 2020, were included. Based on the automatic registration of 80 CBCT, the deviations between images of planning CT and synthetic CT (MR-Only) were compared. Results: In the registration of the images in the rectum, the variation that was obtained was less than 1,4mm longitudinal, 1mm laterally, and vertically. The variation verified in the translations was - 0,2±0,3mm lateral, -0,3±0,4mm vertical, and - 0,4±0,7mm longitudinal. Regarding rotations were lower than 0,4º, with the variation verified 0,0±0,2º pitch, 0,0±0,1º yaw, and 0,0±0,1º roll. In the brain it was less than 1,3mm longitudinally, 0,6mm vertically and 0,4mm laterally. The variation found was -0,2±0,2mm lateral, -0,3±0,2mm vertical, and -0,4±0,5mm longitudinal. In the rotations, a maximum rotation of 0,3º was obtained, being the variation verified -0,2±0,1º pitch, 0,1±0,1º yaw, and of 0,0±0,1º roll. Conclusion: The registration of the synthetic CT image with the CBCT verification image was validated. The minimum deviations found in the results between the planning CT and the synthetic CT of the MRI suggest that the use of the MR-Only technique as a reference image is justified.info:eu-repo/semantics/publishedVersio
    corecore