181 research outputs found

    Experimental study of factors influencing the risk of drift from field sprayers Part 2: Spray application technique.

    Get PDF
    Recently, spray drift and its effects have become an important aspect of risk assessment in the registration process of pesticides in Belgium. In this regulation, drift reducing spray application techniques can be used to reduce buffer zones. The purpose of this research is to measure and compare the amount of drift sediment for different spray application techniques under field conditions. A drift prediction equation for the reference spraying was used to compare other spraying techniques with the reference spraying, under different weather conditions. Drift measurements were performed for several combinations of nozzle type (flat fan, low-drift, air injection) and size (ISO 02, 03, 04 and 06), spray pressure (2, 3 and 4 bar), driving speed (4, 6, 8 and 10 km.h-1) and spray boom height (0.3, 0.5 and 0.75 m). Nozzle type as well as spray pressure, driving speed and spray boom height, have an important effect on the amount of spray drift. Larger nozzle sizes, lower spray pressures and driving speeds and lower spray boom heights generally reduce spray drift. Concerning nozzle types, air injection nozzles have the highest drift reduction potential followed by the low-drift nozzles and the standard flat fan nozzles

    Experimental study of factors influencing the risk of drift from field sprayers, Part 1: Meteorological conditions

    Get PDF
    Spray drift can be defined as the quantity of plant protection product that is carried out of the sprayed (treated) area by the action of air currents during the application process. This continues to be a major problem in applying agricultural pesticides. The purpose of this research is to measure and compare the amount of drift for different climatological conditions under field conditions. Sedimenting spray drift was determined by sampling in a defined downwind area at different positions in a flat meadow using horizontal drift collectors for a reference spraying. Meteorological conditions were monitored during each experiment. A drift prediction equation for the reference spraying was set up to predict the expected magnitude of sedimenting at various drift distances and atmospheric conditions. The measurements proved the important effect of weather conditions (temperature, relative humidity and wind speed) on the amount of spray drift. A lower wind speed or a higher relative humidity decreases the amount of spray drift. Taking into account the correlation between temperature and relative humidity, a lower temperature will also result in lower drift values due to the cumulative effect of relative humidity. This equation can be used to quantify the effect of meteorological conditions, to compare measurements using other spraying techniques under different weather conditions to the reference spraying and to perform spray drift risk assessments

    Mismatch between morphological and functional assessment of the length of coronary artery disease

    Get PDF
    Background: Morphological evaluation of coronary lesion length is a paramount step during invasive assessment of coronary artery disease. Likewise, the extent of epicardial pressure losses can be measured using longitudinal vessel interrogation with fractional flow reserve (FFR) pullbacks. We aimed to quantify the mismatch in lesion length between morphological (based on quantitative coronary angiography, QCA, and optical coherence tomography, OCT) and functional evaluations. Methods: This is a prospective and multicenter study of patients evaluated by QCA, OCT and motorized fractional flow reserve pullbacks (mFFR). The difference in lesion length between the functional and anatomical evaluations was referred to as FAM. Results: 117 patients (131 vessels) were included. Median lesion length derived from angiography was 16.05 mm [11.40–22.05], from OCT was 28.00 mm [16.63–38.00] and from mFFR 67.12 mm [25.38–91.37]. There was no correlation between QCA and mFFR lesion length (r = 0.124, 95% CI -0.168-0.396, p = 0.390). OCT lesion length did correlate with mFFR (r = 0.469, 95% CI 0.156–0.696, p = 0.004). FAM was strongly associated with the improvement in vessel conductance with percutaneous coronary intervention (PCI), higher mismatch was associated with lower post-PCI FFR. Conclusions: Lesion length assessment differs between morphological and functional evaluations. The morphological-functional mismatch in lesion length is frequent, and influences the results of PCI in terms of post-PCI FFR. Integration of the extent of pressure losses provides clinically relevant information that may be useful for clinical decision-making concerning revascularization strategy

    Head-to-head comparison of two angiography-derived fractional flow reserve techniques in patients with high-risk acute coronary syndrome: A multicenter prospective study.

    Get PDF
    FFRangio and QFR are angiography-based technologies that have been validated in patients with stable coronary artery disease. No head-to-head comparison to invasive fractional flow reserve (FFR) has been reported to date in patients with acute coronary syndromes (ACS). This study is a subset of a larger prospective multicenter, single-arm study that involved patients diagnosed with high-risk ACS in whom 30-70% stenosis was evaluated by FFR. FFRangio and QFR - both calculated offline by 2 different and blinded operators - were calculated and compared to FFR. The two co-primary endpoints were the comparison of the Pearson correlation coefficient between FFRangio and QFR with FFR and the comparison of their inter-observer variability. Among 134 high-risk ACS screened patients, 59 patients with 84 vessels underwent FFR measurements and were included in this study. The mean FFR value was 0.82 ± 0.40 with 32 (38%) being ≤0.80. The mean FFRangio was 0.82 ± 0.20 and the mean QFR was 0.82 ± 0.30, with 27 (32%) and 25 (29%) being ≤0.80, respectively. The Pearson correlation coefficient was significantly better for FFRangio compared to QFR, with R values of 0.76 and 0.61, respectively (p = 0.01). The inter-observer agreement was also significantly better for FFRangio compared to QFR (0.86 vs 0.79, p < 0.05). FFRangio had 91% sensitivity, 100% specificity, and 96.8% accuracy, while QFR exhibited 86.4% sensitivity, 98.4% specificity, and 93.7% accuracy. In patients with high-risk ACS, FFRangio and QFR demonstrated excellent diagnostic performance. FFRangio seems to have better correlation to invasive FFR compared to QFR but further larger validation studies are required

    Coronary Atherosclerosis Phenotypes in Focal and Diffuse Disease.

    Get PDF
    The interplay between coronary hemodynamics and plaque characteristics remains poorly understood. The aim of this study was to compare atherosclerotic plaque phenotypes between focal and diffuse coronary artery disease (CAD) defined by coronary hemodynamics. This multicenter, prospective, single-arm study was conducted in 5 countries. Patients with functionally significant lesions based on an invasive fractional flow reserve ≤0.80 were included. Plaque analysis was performed by using coronary computed tomography angiography and optical coherence tomography. CAD patterns were assessed using motorized fractional flow reserve pullbacks and quantified by pullback pressure gradient (PPG). Focal and diffuse CAD was defined according to the median PPG value. A total of 117 patients (120 vessels) were included. The median PPG was 0.66 (IQR: 0.54-0.75). According to coronary computed tomography angiography analysis, plaque burden was higher in patients with focal CAD (87% ± 8% focal vs 82% ± 10% diffuse; P = 0.003). Calcifications were significantly more prevalent in patients with diffuse CAD (Agatston score per vessel: 51 [IQR: 11-204] focal vs 158 [IQR: 52-341] diffuse; P = 0.024). According to optical coherence tomography analysis, patients with focal CAD had a significantly higher prevalence of circumferential lipid-rich plaque (37% focal vs 4% diffuse; P = 0.001) and thin-cap fibroatheroma (TCFA) (47% focal vs 10% diffuse; P = 0.002). Focal disease defined by PPG predicted the presence of TCFA with an area under the curve of 0.73 (95% CI: 0.58-0.87). Atherosclerotic plaque phenotypes associate with intracoronary hemodynamics. Focal CAD had a higher plaque burden and was predominantly lipid-rich with a high prevalence of TCFA, whereas calcifications were more prevalent in diffuse CAD. (Precise Percutaneous Coronary Intervention Plan [P3]; NCT03782688)

    Peluang Peningkatan Tipe Terminal di Kecamatan Banyumaik (Analisis Demand dan Supply)

    Full text link
    Kecamatan Banyumanik merupakan kecamatan yang terus mengalami perkembangan baik dari jumlah penduduk maupun pelayanan kotanya. Kecamatan ini juga berbatasan langsung dengan kabupaten Semarang dan menjadi gerbang koridor semarang atas atau semarang bagian Selatan sehingga memiliki pergerakan yang tinggi sebagai jalur keluar masuknya kota Semarang. Pergerakan yang tinggi tersebut tidak diimbangi dengan ketersediaan fasilitas transportasi pendukung yaitu terminal. Terminal merupakan salah satu fasilitas utama yang memiliki peran penting dalam sistem transportasi. Menurut keputusan menteri nomor 35 tahun 2003 pengertian terminal adalah prasarana transportasi jalan untuk keperluan memuat dan menurunkan orang dan/atau barang serta mengatur kedatangan dan pemberangkatan kendaraan umum, yang merupakan salah satu wujud simpul jaringan transportasi. Terminal juga memiliki peran yang penting sebagai unsur tata ruang dalam kaitannya untuk meningkatkan mobilitas dan efisiensi kehidupan kota. Terminal merupakan tempat untuk mengurangi kemacetan dimana dapat mengatur lokasi pergantian moda transportasi menjadi lebih teratur. Lokasi sebuah terminal harus sesuai dengan rencana tata ruang wilayah (RTRW) dan sesuai dengan kebutuhan masyarakat Di kecamatan Banyumanik hanya memiliki sub terminal atau terminal bantu yang berfungsi sebagai tempat transit dan pergantian moda. Demand yang tinggi terhadap fasilitas transportasi tersebut tidak sebanding dengan supply fasilitas terminal yang tersedia sehingga mengakibatkan timbulnya titik-titik baru yang digunakan masyarakat untuk menunggu angkutan yaitu terminal bayangan. Terminal bayangan ini muncul karena adanya demand yang tinggi dari mayarakat banyumanik terhadap kebutuhan sarana transportasi dan efisiensi waktu. Ketidakseimbangan antara demand dan supply ini mengakibatkan berbagai dampak makro maupun mikro terhadap lalu lintas maupun jaringan angkutan di Kecamatan Banyumanik dan kota Semarang

    Contemporary Management of Stable Coronary Artery Disease.

    Get PDF
    Coronary artery disease (CAD) continues to be the leading cause of mortality and morbidity in developed countries. Assessment of pre-test probability (PTP) based on patient's characteristics, gender and symptoms, help to identify more accurate patient's clinical likelihood of coronary artery disease. Consequently, non-invasive imaging tests are performed more appropriately to rule in or rule out CAD rather than invasive coronary angiography (ICA). Coronary computed tomography angiography (CCTA) is the first-line non-invasive imaging technique in patients with suspected CAD and could be used to plan and guide coronary intervention. Invasive coronary angiography remains the gold-standard method for the identification and characterization of coronary artery stenosis. However, it is recommended in patients where the imaging tests are non-conclusive, and the clinical likelihood is very high, remembering that in clinical practice, approximately 30 to 70% of patients with symptoms and/or signs of ischemia, referred to coronary angiography, have non obstructive coronary artery disease (INOCA). In this contest, physiology and imaging-guided revascularization represent the cornerstone of contemporary management of chronic coronary syndromes (CCS) patients allowing us to focus specifically on ischemia-inducing stenoses. Finally, we also discuss contemporary medical therapeutic approach for secondary prevention. The aim of this review is to provide an updated diagnostic and therapeutic approach for the management of patients with stable coronary artery disease
    corecore