1,729 research outputs found
Development of a drive system for a sequential space camera
An electronically commutated dc motor is reported for driving the camera claw and magazine, and a stepper motor is described for driving the shutter with the two motors synchronized electrically. Subsequent tests on the breadboard positively proved the concept, but further development beyond this study should be done. The breadboard testing also established that the electronically commutated motor can control speed over a wide dynamic range, and has a high torque capability for accelerating loads. This performance suggested the possibility of eliminating the clutch from the system while retaining all of the other mechanical features of the DAC, if the requirement for independent shutter speeds and frame rates can be removed. Therefore, as a final step in the study, the breadboard shutter and shutter drive were returned to the original DAC configuration, while retaining the brushless dc motor drive
Development of a drive system for a sequential space camera
Breadboard models of single and dual motor drives for the shutter, claw and magazine of a space camera system were designed and tested. The single motor technique utilizes a single electronically commutated motor to drive the claw and shutter without resorting to a solenoid actuated clutch for pulse operation. Shutter speed is established by a combination of the cinemode speed and the opening of the conventional DAC two piece shutter. Pulse mode operation is obtained by applying power at a fixed clock rate and removing power at an appropriate point in the mechanical cycle such that the motor comes to rest by system friction. The dual motor approach utilizes a stepper motor to drive the shutter and an electronically commutated dc motor to drive the claw and magazine functions. The motors are synchronized electronically
Development of a drive system for a sequential space camera contract modification 4(S)
The brush type dc motor and clutch were eliminated from the design of the 16 mm space sequential camera design and replaced by an electronically commutated motor. The new drive system reduces the current consumption at 24 fps to 220 mA. The drive can be programmed and controlled externally from the multipurpose programmable timer/intervalometer, as well as being controlled locally from the camera
Automatic exposure control for space sequential camera
The final report for the automatic exposure control study for space sequential cameras, for the NASA Johnson Space Center is presented. The material is shown in the same sequence that the work was performed. The purpose of the automatic exposure control is to automatically control the lens iris as well as the camera shutter so that the subject is properly exposed on the film. A study of design approaches is presented. Analysis of the light range of the spectrum covered indicates that the practical range would be from approximately 20 to 6,000 foot-lamberts, or about nine f-stops. Observation of film available from space flights shows that optimum scene illumination is apparently not present in vehicle interior photography as well as in vehicle-to-vehicle situations. The evaluation test procedure for a breadboard, and the results, which provided information for the design of a brassboard are given
Automatic Exposure Iris Control (AEIC) for data acquisition camera
A lens design capable of operating over a total range of f/1.4 to f/11.0 with through the lens light sensing is presented along with a system which compensates for ASA film speeds as well as shutter openings. The space shuttle camera system package is designed so that it can be assembled on the existing 16 mm DAC with a minimum of alteration to the camera
WSO/UV: World Space Observatory/Ultraviolet
We summarize the capabilities of the World Space Observatory (UV) Project
(WSO/UV). An example of the importance of this project (with a planned launch
date of 2007/8) for the study of Classical Novae is given.Comment: 4 pages, To appear in the proceeedings of the "Classical Nova
Explosions" conference, eds. M. Hernanz and J. Jose, AI
VO2 Reserve vs. Heart Rate Reserve During Moderate Intensity Treadmill Exercise
International Journal of Exercise Science 7(4) : 311-317, 2014. ÂVO2 and heart rate (HR) are widely used when determining appropriate training intensities for clinical, healthy, and athletic populations. It has been shown that if the % reserve (%R) is used, rather than % of max, HR and VO2 can be used interchangeably to accurately prescribe exercise intensities. Thus, heart rate reserve (HRR) can be prescribed if VO2 reserve (VO2R) is known. Therefore, the purpose of this study was to compare VO2 R and HRR during moderate intensity exercise (50%R). Physically active college students performed a maximal treadmill test to exhaustion. During which VO2 and HR were monitored to determine max values. Upon completion of the maximal test, calculations were made to determine the % grade expected to yield approximately 50% of the subjects VO2R. Subjects then returned to complete the submaximal test (50%R) at least two days later. The %VO2R and %HRR were calculated and compared to the predicted value as well as to each other. Statistical analysis revealed that VO2 at 50%R was significantly greater than the actual VO2 achieved, p \u3c .001. Conversely, the mean predicted HRat 50%R was significantly less than the actual HR achieved, p \u3c .001. In conclusion, this study indicated that VO2 could be more accurately predicted than HR during moderate intensity exercise. The weak correlation between VO2R and HRR indicates that caution should be used when relying on a HR to determine VO2
Anodic dissolution of metals in oxide-free cryolite melts
The anodic behavior of metals in molten cryolite-alumina melts has been investigated mostly for use as inert anodes for the Hall-Héroult process. In the present work, gold, platinum, palladium, copper, tungsten, nickel, cobalt and iron metal electrodes were anodically polarized in an oxide-free cryolite melt (11%wt. excess AlF3 ; 5%wt. CaF2) at 1273 K. The aim of the experiments was to characterize the oxidation reactions of the metals occurring without the effect of oxygen-containing dissolved species. The anodic dissolution of each metal was demonstrated, and electrochemical reactions were assigned using reversible potential calculation. The relative stability of metals as well as the possibility of generating pure fluorine is discussed
Hot White Dwarf Donors in Ultracompact X-Ray Binaries
The discovery of two accreting millisecond X-ray pulsars in binaries with 43
minute orbital periods allows for a new probe of the donor's structure. For XTE
J1751-305, only a hot white dwarf (WD) can fill the Roche Lobe. A cold He WD is
a possible solution for XTE J0929-314, though I will show that evolutionary
arguments make a hot WD more likely. In addition to being larger than the T=0
models, these finite entropy, low-mass (<0.03 solar masses) WDs have a minimum
mass for a fixed core temperature. If they remain hot as they lose mass and
expand, they can ``evaporate'' to leave an isolated millisecond radio pulsar.
They also adiabatically expand upon mass loss at a rate faster than the growth
of the Roche radius if the angular momentum deposited in the disk is not
returned to the donor. If the timescale of the resulting runaway mass transfer
is shorter than the viscous timescale in the outer disk, then the mass transfer
instability of Ruderman and Shaham for He WDs would be realized. However, my
estimates of these timescales still makes the instability unlikely for
adiabatic responses. I close by noting the possible impact of finite T WDs on
our understanding of AM CVn binaries.Comment: to appear in Astrophysical Journal Letter
- …