103 research outputs found

    Beyond Hopkinson's bar

    No full text
    In order to perform experimental identification of high strain rate material models, engineers have only a very limited toolbox based on test procedures developed decades ago. The best example is the so-called split Hopkinson pressure bar based on the bar concept introduced 100 years ago by Bertram Hopkinson to measure blast pulses. The recent advent of full-field deformation measurements using imaging techniques has allowed novel approaches to be developed and exciting new testing procedures to be imagined for the first time. One can use this full-field information in conjunction with efficient numerical inverse identification tools such as the virtual fields method (VFM) to identify material parameters at high rates. The underpinning novelty is to exploit the inertial effects developed in high strain rate loading. This paper presents results from a new inertial impact test to obtain stress–strain curves at high strain rates (here, up to 3000 s−1). A quasi-isotropic composite specimen is equipped with a grid and images are recorded with the new HPV-X camera from Shimadzu at 5 Mfps and the SIMX16 camera from Specialised Imaging at 1 Mfps. Deformation, strain and acceleration fields are then input into the VFM to identify the stiffness parameters with unprecedented quality

    Remote monitoring of vibrational information in spider webs

    Get PDF
    Spiders are fascinating model species to study information-acquisition strategies, with the web acting as an extension of the animal’s body. Here, we compare the strategies of two orb-weaving spiders that acquire information through vibrations transmitted and filtered in the web. Whereas Araneus diadematus monitors web vibration directly on the web, Zygiella x-notata uses a signal thread to remotely monitor web vibration from a retreat, which gives added protection. We assess the implications of these two information-acquisition strategies on the quality of vibration information transfer, using laser Doppler vibrometry to measure vibrations of real webs and finite element analysis in computer models of webs. We observed that the signal thread imposed no biologically relevant time penalty for vibration propagation. However, loss of energy (attenuation) was a cost associated with remote monitoring via a signal thread. The findings have implications for the biological use of vibrations by spiders, including the mechanisms to locate and discriminate between vibration sources. We show that orb-weaver spiders are fascinating examples of organisms that modify their physical environment to shape their information-acquisition strategy

    The mechanism of rate-dependent off-axis compression of a low fibre volume fraction thermoplastic matrix composite

    Get PDF
    This paper reports on the mechanism of rate-dependent off-axis compression of a unique unidirectional composite with unusually high matrix volume fraction of 65%. The test material is an E-glass fibre reinforced polypropylene composite and was subjected to quasi-static, medium and high strain rates (with strain rates from 10-3 s−1 to 103 s−1). This paper has shown experimental evidence of significant rate-dependence of yielding, strain softening and fracture strain of the test composite. Also, the study reports on the effect of strain rates on evolution of different failure modes of the composite. The observed rate-dependence was shown to result from the influence of the pure matrix on the constitutive behaviour of the composite. The work has used a two-process Ree-Eyring yield model of the matrix to demonstrate the origin of the observed rate-dependent yielding of the composite. The data derived in this study will be significant for further micro-mechanical modelling of finite deforming composites used in especially damage tolerant applications. Composite design engineers and stress analysis experts should benefit also from the findings in this work

    On the mechanical behaviour of PEEK and HA cranial implants under impact loading

    Get PDF
    The human head can be subjected to numerous impact loadings such as those produced by a fall or during sport activities. These accidents can result in skull fracture and in some complex cases, part of the skull may need to be replaced by a biomedical implant. Even when the skull is not damaged, such accidents can result in brain swelling treated by decompressive craniectomy. Usually, after recovery, the part of the skull that has been removed is replaced by a prosthesis. In such situations, a computational tool able to analyse the choice of prosthesis material depending on the patient's specific activity has the potential to be extremely useful for clinicians. The work proposed here focusses on the development and use of a numerical model for the analysis of cranial implants under impact conditions. In particular, two main biomaterials commonly employed for this kind of prosthesis are polyether-ether-ketone (PEEK) and macroporous hydroxyapatite (HA). In order to study the suitability of these implants, a finite element head model comprising scalp, skull, cerebral falx, cerebrospinal fluid and brain tissues, with a cranial implant replacing part of the skull has been developed from magnetic resonance imaging data. The human tissues and these two biocompatible materials have been independently studied and their constitutive models are provided here. A computational model of the human head under impact loading is then implemented and validated, and a numerical comparison of the mechanical impact response of PEEK and HA implants is presented. This comparison was carried out in terms of the effectiveness of both implants in ensuring structural integrity and preventing traumatic brain injury.The researchers of the University Carlos III are indebted to the Ministerio de EconomĂ­a y Competitividad de España (Project DPI2014-57989-P) and Vicerrectorado de PolĂ­tica CientĂ­fica UC3M (Project 2013-00219-002) for the financial support. A.J. acknowledges funding from the European Union's Seventh Framework Programme (FP7 2007–2013) ERC Grant Agreement No. 306587. MRI data were provided by the Human Connectome Project, WUMinn Consortium (Principal Investigators: David Van Essen and Kamil Ugurbil; 1U54MH091657) funded by the 16 NIH Institutes and Centers that support the NIH Blueprint for Neuroscience Research; and by the McDonnell Center for Systems Neuroscience at Washington University. Finally, we would like to thank Dr. S Barhli and Prof. J Marrow for valuable assistance with the X-ray tomography; the machine used was bought from EPSRC Grant EP/M02833X/1 “University of Oxford: experimental equipment upgrade”. Open Access funded by European Research Counci

    Characterization and physical properties of aluminium foam−polydimethylsiloxane nanocomposite hybrid structures

    Get PDF
    This article reports on the fabrication and characterisation of hybrid structures prepared by impregnating an open-cell aluminum foam with polydimethylsiloxane (PDMS) or PDMS reinforced with graphene oxide, GO (PDMS nanocomposite). The effect of the PDMS and the GO on the mechanical, thermal, acoustic absorption and fire retardancy properties of the resulting hybrid structures were evaluated and compared to the individual components (PDMS, PDMS nanocomposite, open-cell aluminium foams). Results demonstrate that the use of the PDMS cured at 65 °C, as an void filler of the open-cell aluminium foams, changes mechanical and deformation performance, from a rubbery to brittle behaviour, however attaining a higher level of strength (quasi-static: ∌5 MPa; dynamic: > 15 MPa) in the resulting hybrid structures. This change is due to the low chain mobility of the polymer and effective adhesion with struts of the open-cell aluminium foams. Furthermore, these hybrid structures are extremely sensitive to strain-rate testing, exhibiting a maximum compressive stress increase of more than 300 % and 200 %, respectively. The presence of the GO within the PDMS improves significantly the non-flammability of the hybrid structures and increases the sound absorption coefficient.publishe

    Predicting the high strain rate response of plasticised poly(vinyl chloride) using a fractional derivative model

    No full text
    Polymers are frequently used in fields as diverse as aerospace, biomedicine, automotive and in-dustrial vibration damping, where they are often subjected to high strain rate or impact loading. Poly(vinyl chloride) (PVC), and its plasticised variants (PPVC), are just two examples of this broad category of materi-als. Since many polymers exhibit strong rate and temperature dependence, including a low temperature brittle transition, it is extremely important to understand their mechanical responses over a wide range of loading con-ditions.PVC with 60 wt% plasticiser is used in this study, as its highly rubbery nature lends itself well to being used in various load mitigation and energy absorption applications. It is challenging to obtain high strain rate data on rubbery materials using conventional techniques such as the split-Hopkinson (Kolsky) bar. Therefore, alternative approaches are required. Based on previous work developing a framework to predict high rate re-sponseusing a fractional derivative model, Dynamic Mechanical Analysis (DMA) experiments are conducted on the PPVC to construct a master curve of storage modulus. These data are used to part-calibrate a modified Mulliken-Boyce model which also takes into account specimen heating to derive stress-strain relationships at strain rates varying from 0.001 s_1 to 13 500 s_1. This model is further calibrated against experiments conducted in a previous study and shown to provide an excellent description of the behaviour at these rates

    Mechanical response of four polycarbonates at a wide range of strain rates and temperatures

    No full text
    This file includes the raw mechanical test data, e.g. DMA, DSC; At the same time, the processed compression test data are also uploaded (each test for 3)
    • 

    corecore