112 research outputs found

    Energy Efficiency of the Road Lighting: The Impact of Active Power Losses on Energy Performance Indicators and Electricity Costs

    Get PDF
    Improving the energy efficiency of road lighting is currently one of the most important issues. One of the methods of improving energy efficiency is the use of dimmable luminaires. In order to be able to compare the energy efficiency of different technical solutions, EN 13201-5 introduces energy performance indicators for road lighting installations. The chapter describes energy performance indicators for road installation and the impact of active power losses on these indicators and electricity costs. In order to accurately calculate the above indicators, the active power losses in the elements of the lighting installation should be taken into account. The chapter presents the dependencies which can be used to calculate the active power losses in single- and three-phase systems. In addition, an example of calculation of energy performance indicators, active power and energy losses and electricity costs is provided. The calculation was made for an exemplary installation of road lighting with dimmable luminaires. The analysis was done for single-phase and three-phase installations

    The active power losses in the road lighting installation with dimmable LED luminaires

    Get PDF
    In accordance with the requirements of PN EN 13201-5 standard for road lighting installation, energy performance indicators should be descripted. In order to calculate energy performance indicators, it is necessary to know the active power of the road lighting system. The above standard does not specify whether active power losses should be taken into account in calculations. The main purpose of the article is to estimate the active power losses in the road lighting installation. The article presents methods for calculating active power losses, taking into account losses in all main elements of the installation. The obtained calculation results show the relationship between active power losses and the power of luminaires, their number and spacing between poles. Calculations of active power losses were made for single-phase and three-phase installations. The active power losses in a three-phase system do not exceed 1.5% and in a single-phase installation they may be greater than 7%. Therefore, in order to obtain exact values of energy performance indicators (and also predict electricity consumption), active power losses should be taken into account in calculations. In addition, a comparative analysis of the effect of luminaires dimming and active power losses on annual CO2 emissions was made. Not taking into account the active power losses in the calculation of the lighting installation’s power, for single-phase installations in particular, understates the calculated value of CO2 emissions by more than 6%

    ELEKTRYCZNY TOMOGRAF REZYSTANCYJNY DO POMIARÓW ROZPROSZONYCH DLA WAŁÓW PRZECIWPOWODZIOWYCH

    Get PDF
    In this paper the terrain electrical resistance tomograph was presented. Its aim is to verify the repeatability of test results by eliminating laboratory equipment, and to validate the use of simple and cheap electronics to the structure of the ERT. Electrical resistance tomography, which is based on measuring potential difference, can be used to calculate conductivityW niniejszym artykule przedstawiono konstrukcję tomografu rezystancyjnego. Jego celem jest weryfikacja powtarzalności wyników badań poprzez wyeliminowanie sprzętu laboratoryjnego oraz potwierdzenie zastosowania prostej i taniej elektroniki do struktury ERT. Do obliczenia przewodnictwa można wykorzystać elektryczną tomografię rezystancyjną, która opiera się na pomiarze różnicy potencjałó

    Spektroskopia fluorescencyjna kolagenu w różnych rozpuszczalnikach

    Get PDF
    Introduction. Research was carried out into the influence of microenvironment created by 6 solvents on the spectroscopic characteristics of four types of collagen protein. The solvents were selected on the basis of polarity, pH, the presence of a functional group, as well as their application in fixing biological material for histopathological and spectroscopic examinations. As an amino acid with the highest light-absorbing capacity, tryptophan exhibits the spectral properties of whole protein agglomerates. Protein conformation changes occurring in different environments and changes in functional groups surrounding tryptophan allowed to register protein spectra. The aim of the study was to find out whether changing the collagen microenvironment using six selected solvents allows to differentiate four types of collagen by means of stationary fluorescence spectroscopy. Material and methods. The research material consisted of four types of human collagen: I, II, III, and IV. The classification of collagen types was based on the spatial arrangement of α chains of each collagen type as adopted by Bornstein and Traub. The emission spectra were recorded with the use of a Hitachi F-7000 spectrofluorimeter and analysed with Origin 8.0 Pro software. Results. Preliminary tests allowed to determine the most optimal excitation wavelength of polar (λ = 270 nm) and non-polar (λ = 350 nm) solvents. The observed spectra shapes and maxima at a specific excitation wavelength were characteristic for the corresponding solvent. Differences among the fluorescence spectra of the four types of collagen were not observed. Conclusions and discussion. Stationary fluorescence spectroscopy does not allow to differentiate four collagen types using the selected solvents. A major hindrance of this method consists in its high sensitivity to environment changes which may preclude the optimisation of research and in consequence render the approach inferior to techniques using electrophoretic devices, mass spectrometry, or chromatography.Wstęp. Przeprowadzono badania wpływu mikrośrodowiska wybranych sześciu rozpuszczalników na właściwości spektroskopowe czterech typów białka kolagenowego. Rozpuszczalniki zostały wyselekcjonowane na podstawie polarności, pH, obecności grup funkcyjnych, a także wykorzystania ich do utrwalania materiału biologicznego do badań histopatologicznych, jak również badań spektroskopowych. Tryptofan, jako aminokwas o najsilniejszej zdolności absorbowania światła odwzorowuje spektralne właściwości całych aglomeratów białkowych. Zmiany konformacyjne białka w różnym środowisku oraz zmiany otaczających tryptofan grup funkcyjnych pozwoliły na zarejestrowanie widm białek. Celem badania było sprawdzenie, czy zmiana mikrośrodowiska kolagenu z wykorzystaniem sześciu wybranych rozpuszczalników pozwoli na różnicowanie czterech typów kolagenu metodą stacjonarnej spektroskopii fluorescencyjnej. Materiały i metody. Materiał do badań stanowiły cztery typy kolagenu ludzkiego: I, II, III i IV. Podział typów kolagenu opierał się na przyjętym przez Bordsteina i Trauba ułożeniu przestrzennym łańcuchów α każdego z typów kolagenu. Widma emisji rejestrowane były przy użyciu spektrofluorymetrumetru Hitachi F-7000 i opracowane z wykorzystaniem programu Origin 8.0 Pro. Wyniki. Badania wstępne pozwoliły na wyznaczenie najbardziej optymalnych długości fali wzbudzenia dla rozpuszczalników polarnych (λ = 270 nm) i niepolarnych (λ = 350 nm). Obserwowany kształt oraz maksimum widm przy określonej długości fali wzbudzenia był charakterys-tyczny dla odpowiedniego rozpuszczalnika. Nie zaobserwo-wano różnic w widmach fluorescencji pomiędzy czterema typami kolagenu. Wnioski i dyskusja. Stacjonarna spektroskopia fluorescencyjna nie pozwala na rozróżnienie czterech typów kolagenu z zastosowaniem wybranych rozpuszczalników. Dużym utrudnieniem w pomiarach fluorescencyjnych stanowi jej wysoka czułość na zmiany środowiska, która niestety może powodować uniemożliwienie optymalizacji badań, dlatego ustępuje miejsca metodom z użyciem aparatury elektroforetycznej, spektrometrii mas lub chromatografii

    Fluorescence Spectroscopy of Collagen in Several Solvents

    Get PDF
    Introduction. Research was carried out into the influence of microenvironment created by 6 solvents on the spectroscopic characteristics of four types of collagen protein. The solvents were selected on the basis of polarity, pH, the presence of a functional group, as well as their application in fixing biological material for histopathological and spectroscopic examinations. As an amino acid with the highest light-absorbing capacity, tryptophan exhibits the spectral properties of whole protein agglomerates. Protein conformation changes occurring in different environments and changes in functional groups surrounding tryptophan allowed to register protein spectra. The aim of the study was to find out whether changing the collagen microenvironment using six selected solvents allows to differentiate four types of collagen by means of stationary fluorescence spectroscopy. Material and methods. The research material consisted of four types of human collagen: I, II, III, and IV. The classification of collagen types was based on the spatial arrangement of α chains of each collagen type as adopted by Bornstein and Traub. The emission spectra were recorded with the use of a Hitachi F-7000 spectrofluorimeter and analysed with Origin 8.0 Pro software. Results. Preliminary tests allowed to determine the most optimal excitation wavelength of polar (λ = 270 nm) and non-polar (λ = 350 nm) solvents. The observed spectra shapes and maxima at a specific excitation wavelength were characteristic for the corresponding solvent. Differences among the fluorescence spectra of the four types of collagen were not observed. Conclusions and discussion. Stationary fluorescence spectroscopy does not allow to differentiate four collagen types using the selected solvents. A major hindrance of this method consists in its high sensitivity to environment changes which may preclude the optimisation of research and in consequence render the approach inferior to techniques using electrophoretic devices, mass spectrometry, or chromatography.Wstęp. Przeprowadzono badania wpływu mikrośrodowiska wybranych sześciu rozpuszczalników na właściwości spektroskopowe czterech typów białka kolagenowego. Rozpuszczalniki zostały wyselekcjonowane na podstawie polarności, pH, obecności grup funkcyjnych, a także wykorzystania ich do utrwalania materiału biologicznego do badań histopatologicznych, jak również badań spektroskopowych. Tryptofan, jako aminokwas o najsilniejszej zdolności absorbowania światła odwzorowuje spektralne właściwości całych aglomeratów białkowych. Zmiany konformacyjne białka w różnym środowisku oraz zmiany otaczających tryptofan grup funkcyjnych pozwoliły na zarejestrowanie widm białek. Celem badania było sprawdzenie, czy zmiana mikrośrodowiska kolagenu z wykorzystaniem sześciu wybranych rozpuszczalników pozwoli na różnicowanie czterech typów kolagenu metodą stacjonarnej spektroskopii fluorescencyjnej. Materiały i metody. Materiał do badań stanowiły cztery typy kolagenu ludzkiego: I, II, III i IV. Podział typów kolagenu opierał się na przyjętym przez Bordsteina i Trauba ułożeniu przestrzennym łańcuchów α każdego z typów kolagenu. Widma emisji rejestrowane były przy użyciu spektrofluorymetrumetru Hitachi F-7000 i opracowane z wykorzystaniem programu Origin 8.0 Pro. Wyniki. Badania wstępne pozwoliły na wyznaczenie najbardziej optymalnych długości fali wzbudzenia dla rozpuszczalników polarnych (λ = 270 nm) i niepolarnych (λ = 350 nm). Obserwowany kształt oraz maksimum widm przy określonej długości fali wzbudzenia był charakterys-tyczny dla odpowiedniego rozpuszczalnika. Nie zaobserwo-wano różnic w widmach fluorescencji pomiędzy czterema typami kolagenu. Wnioski i dyskusja. Stacjonarna spektroskopia fluorescencyjna nie pozwala na rozróżnienie czterech typów kolagenu z zastosowaniem wybranych rozpuszczalników. Dużym utrudnieniem w pomiarach fluorescencyjnych stanowi jej wysoka czułość na zmiany środowiska, która niestety może powodować uniemożliwienie optymalizacji badań, dlatego ustępuje miejsca metodom z użyciem aparatury elektroforetycznej, spektrometrii mas lub chromatografii

    SZANSE NA WZROST DOKŁADNOŚCI OBRAZOWANIA ULTRADŹWIĘKOWEGO

    Get PDF
    The results of ultrasonic imaging with the aid of an algorithm with the virtual rays is presented in this paper. The signal associated with the virtual rays is calculated as an arithmetical mean value of the signals of the rays surrounding the virtual one. Developed algorithm was tested on synthetic free noise data then polluted synthetic data in order to move for the real measurements. Conclusions about the imaging with new algorithm are not obvious. In same cases the significant improvement was achieved but in some not.W pracy przedstawiono rezultaty działania algorytmu obrazowania ultradźwiękowego z dodatkowymi wirtualnymi promieniami. Sygnał odpowiadający wirtualnym promieniom jest wyliczany jako średnia arytmetyczna rzeczywistych sygnałów pomiarowych odpowiadających promieniom otaczającym dany promień wirtualny. Zaproponowany algorytm najpierw przetestowano na danych syntetycznych niezaszumionych, następnie na danych zaszumionych aby następnie przejść do danych pomiarowych. Wnioski na temat tego czy promienie wirtualne mają szanse podnieść jakość obrazowania nie są jednoznaczne. W niektórych przypadkach jakość jest znacznie lepsza a w innych nie

    KONCEPCJA SYSTEMU DETEKCJI DO LOKALIZACJI WEWNĄTRZ OBSZARÓW ZAMKNIĘTYCH Z WYKORZYSTANIEM TOMOGRAFII RADIOWEJ

    Get PDF
    System for navigation and localization inside buildings will determine man's location in confined spaces with level of accuracy never yet achieved. System's operation will be mainly based on Bluetooth signals in accordance with the Beacon standard. A worldwide innovation will be the use of Radio Tomographic Imaging (RTI). This technology will enable tracking of moving objects by image reconstruction based on changes of electromagnetic field signal strength (RSS).System do nawigacji wewnątrz budynków będzie umożliwiał określenie pozycji człowieka w zamkniętych pomieszczeniach z dużą precyzją. Działanie systemu będzie opierało się na sygnałach Bluetooth zgodnie ze standardem Beacon.. Innowacyjnym rozwiązaniem będzie zastosowanie tomografii radiowej (ang. Radio Tomographic Imaging (RTI)). Wykorzystanie tej technologii umożliwi śledzenie poruszających się obiektów poprzez rekonstrukcję obrazu na podstawie zmian siły sygnału (RSS) pola elektromagnetycznego

    Density functional theory study of Au-fcc/Ge and Au-hcp/Ge interfaces

    Get PDF
    In recent years, nanostructures with hexagonal polytypes of gold have been synthesised, opening new possibilities in nanoscience and nanotechnology. As bulk gold crystallizes in the fcc phase, surface effects can play an important role in stabilizing hexagonal gold nanostructures. Here, we investigate several heterostructures with Ge substrates, including the fcc and hcp phases of gold that have been observed experimentally. We determine and discuss their interfacial energies and optimized atomic arrangements, comparing the theory results with available experimental data. Our DFT calculations for the Au-fcc(011)/Ge(001) junction show how the presence of defects in the interface layer can help to stabilize the atomic pattern, consistent with microscopic images. Although the Au-hcp/Ge interface is characterized by a similar interface energy, it reveals large atomic displacements due to significant mismatch. Finally, analyzing the electronic properties, we demonstrate that Au/Ge systems have metallic character, but covalent-like bonding states between interfacial Ge and Au atoms are also present

    Placebo Groups in Research on the Effectiveness of ABA Therapeutic Techniques

    Get PDF
    Behavior analysts have shown that a single-subject experimental design (SSED) is a useful tool for identifying the effectiveness of specific therapeutic techniques, whereas researchers outside applied behavior analysis (ABA) maintain that randomized placebo-controlled trials (RPCT) provide the most definite test of efficacy. In this paper the possible benefits that could result from supporting SSED studies by placebo control groups are discussed. However, the use of placebo groups in psychotherapy research arouses considerable controversy and many researchers argue against it. The main aim of this paper is to clarify theoretical and methodological problems associated with using placebo groups in psychotherapy research and to demonstrate that these problems can be solved if the assumptions on which they are based are reformulated. The article also discusses ethical issues about the use of placebo groups in research on the effectiveness of psychotherapy
    corecore