15 research outputs found

    Optimization of Cannula Visibility during Ultrasound-Guided Subclavian Vein Catheterization, via a Longitudinal Approach, by Implementing Echogenic Technology

    Get PDF
    Objective. One limitation of ultrasound-guided vascular access is the technical challenge of visualizing the cannula during insertion into the vessel. We hypothesized that the use of an echogenic vascular cannula (EC) would improve visualization when compared with a nonechogenic vascular cannula (NEC) during real-time ultrasound-guided subclavian vein (SCV) cannulation in the ICU. Material and Methods. Eighty mechanically ventilated patients were prospectively enrolled in a randomized study that was conducted in a medical-surgical ICU. Forty patients underwent EC and 40 patients were randomized to NEC. The procedure was ultrasound-guided SCV cannulation via the infraclavicular approach on the longitudinal axis. Results. The EC group exhibited increased cannula visibility as compared to the NEC group (92%±3% versus 85 ± 7%, resp., P < 0.01). There was strong agreement between the procedure operators and independent observers (k = 0.9, 95% confidence intervals assessed by bootstrap analysis = 0.87 to 0.93; P < 0.01). Access time (12.1 s ± 6.5 versus 18.9 s ± 10.9) and the perceived technical difficulty of the ultrasound method (4.5 ± 1.5 versus 7.5 ± 1.5) were both decreased in the EC group compared to the NEC group (P < 0.05). Conclusions. Echogenic technology significantly improved cannula visibility and decreased access time and technical complexity optimizing thus real-time ultrasound-guided SCV cannulation via a longitudinal approach

    Echogenic Technology Improves Cannula Visibility during Ultrasound-Guided Internal Jugular Vein Catheterization via a Transverse Approach

    Get PDF
    Objective. Echogenic technology has recently enhanced the ability of cannulas to be visualized during ultrasound-guided vascular access. We studied whether the use of an EC could improve visualization if compared with a nonechogenic vascular cannula (NEC) during real-time ultrasound-guided internal jugular vein (IJV) cannulation in the intensive care unit (ICU). Material and Methods. We prospectively enrolled 80 mechanically ventilated patients who required central venous access in a randomized study that was conducted in two medical-surgical ICUs. Forty patients underwent EC and 40 patients were randomized to NEC. The procedure was ultrasound-guided IJV cannulation via a transverse approach. Results. The EC group exhibited increased visibility as compared to the NEC group (88%  ± 8% versus 20%  ± 15%, resp. P < 0.01). There was strong agreement between the procedure operators and independent observers (k = 0.9; 95% confidence intervals assessed by bootstrap analysis = 0.87–0.95; P < 0.01). Access time (5.2 s ± 2.5 versus 10.6 s ± 5.7) and mechanical complications were both decreased in the EC group compared to the NEC group (P < 0.05). Conclusion. Echogenic technology significantly improved cannula visibility and decreased access time and mechanical complications during real-time ultrasound-guided IJV cannulation via a transverse approach

    Smooth transitions in critical care

    No full text

    Monitoring of the Adult Patient on Venoarterial Extracorporeal Membrane Oxygenation

    No full text
    Venoarterial extracorporeal membrane oxygenation (VA ECMO) provides mechanical support to the patient with cardiac or cardiopulmonary failure. This paper reviews the physiology of VA ECMO including the determinants of ECMO flow and gas exchange. The efficacy of this therapy may be determined by assessing patient hemodynamics and device flow, overall gas exchange support, markers of adequate oxygen delivery, and pulsatility of the arterial blood pressure waveform

    Ultrasound-guided cannulation of the femoral vein in electrophysiological procedures: a systematic review and meta-analysis

    No full text
    In an effort to minimize periprocedural stroke risk, increasingly, electrophysiological (EP) procedures are being performed on anticoagulation. The decrease in stroke has been accompanied by an increase in potentially devastating vascular access complications. Ultrasound guidance for femoral vein cannulation reduces complications in other applications. The aim of this study is to determine the utility of real-time two-dimensional (2D) ultrasound guidance for femoral vein cannulation in EP
    corecore