294 research outputs found

    Case Report Jejunogastric intussusception: a rare complication of gastric cancer surgery

    Get PDF
    Abstract: Jejunogastric intussusception (JGI) is a rare condition and less than 200 cases have been published since its first description in 1914. In addition, JGI is potentially lethal complication of gastrectomy or gastrojejunostomy. We report the case of a 73-year-old man with a history of a Billroth II procedure who presented to the emergency department after 6 hours of epigastric pain and hematemesis. Endoscopy and computed tomography showed intussuscepted jejunum through a gastrojejunostomy that required emergency operation. At laparotomy a retrograde type II, JGI was confirmed and managed by resection of involved intestine. Postoperative recovery was uneventful. This case presents the rare complication of acute jejunogastric intussusception more than 25 years after a Billroth II procedure

    Traumatic Neuroma around the Celiac Trunk after Gastrectomy Mimicking a Nodal Metastasis: A Case Report

    Get PDF
    Traumatic neuroma is a well-known disorder that occurs after trauma or surgery involving the peripheral nerve and develops from a nonneoplastic proliferation of the proximal end of a severed, partially transected, or injured nerve. We present a case of traumatic neuroma around the celiac trunk after gastrectomy in a 56-year-old man, which was confirmed by pathology. CT demonstrated the presence of a lobulated, homogeneous, hypoattenuating mass around the celiac trunk, mimicking a nodal metastasis

    Enhancement of seawater corrosion resistance in copper using acetone-derived graphene coating

    Get PDF
    We show that acetone-derived graphene coating can effectively enhance the corrosion efficiency of copper (Cu) in a seawater environment (0.5-0.6 M (???3.0-3.5%) sodium chloride). By applying a drop of acetone (???20 ??l cm-2) on Cu surfaces, rapid thermal annealing allows the facile and rapid synthesis of graphene films on Cu surfaces with a monolayer coverage of almost close to ???100%. Under optimal growth conditions, acetone-derived graphene is found to have a relatively high crystallinity, comparable to common graphene grown by chemical vapor deposition. The resulting graphene-coated Cu surface exhibits 37.5 times higher corrosion resistance as compared to that of mechanically polished Cu. Further, investigation on the role of graphene coating on Cu surfaces suggests that the outstanding corrosion inhibition efficiency (IE) of 97.4% is obtained by protecting the underlying Cu against the penetration of both dissolved oxygen and chlorine ions, thanks to the closely spaced atomic structure of the graphene sheets. The increase of graphene coating thickness results in the enhancement of the overall corrosion IE up to ???99%, which can be attributed to the effective blocking of the ionic diffusion process via grain boundaries. Overall, our results suggest that the acetone-derived graphene film can effectively serve as a corrosion-inhibiting coating in the seawater level and that it may have a promising role to play for potential offshore coating.close0

    Association between vitamin D level and hematuria from a dipstick test in a large scale population based study: Korean National Health and nutrition examination survey

    Get PDF
    Background Vitamin D deficiency is an important health concern because it is related to several comorbidities and mortality. However, its relationship with the risk of hematuria remains undetermined in the general population. In this study, we analyzed the association between vitamin D deficiency and hematuria. Methods We conducted cross-sectional analysis using data of participants from the Korean National Health and Nutrition Examination Survey (KNHANES) 2010–2014. A total of 20,240 participants, aged ≥18 years old, were analyzed. Serum 25-hydroxyvitamin D (25(OH)D) levels were measured in a central laboratory and hematuria was defined as ≥1+ on a dipstick test. Multivariate logistic regression was conducted to calculate the odds ratio (OR) of hematuria risk according to serum 25(OH)D quartiles, after adjusting several covariates. Results A total 3144 (15.5%) participants had hematuria. The mean 25(OH)D level was 17.4 ± 6.2 ng/mL (median, 16.6 ng/mL (interquartile range, 13.1–20.8 ng/mL)). The 3rd and 4th quartiles had a higher risk of hematuria than the 1st quartile, with adjusted ORs 1.26 (1.114–1.415) and 1.40 (1.240–1.572) in the 3rd and 4th quartiles, respectively. However, this relationship was only significant in women, not in men. When stratified analyses were conducted according to menopausal status, there was a significant increase of hematuria risk according to quartiles in postmenopausal but not in premenopausal women. Conclusion We found that vitamin D deficiency is correlated with hematuria in women, particularly after menopause. Further interventional studies are warranted to address whether correcting vitamin D deficiency can lower the risk of hematuria

    Prostate Cancer with Solitary Metastases to the Bilateral Testis

    Get PDF
    We present the case of an 81-year-old patient with testicular metastasis from prostate carcinoma. After the initial diagnosis of prostate cancer, he had an 8-year course of hormonal therapy and showed no clinical evidence of metastasis to other organs. Asymptomatic metastasis of prostate carcinoma to the testis is a rare clinical condition. We diagnosed his condition, based on histopathology following a subcapsular orchiectomy and transurethral resection of the prostate

    Conical Ground Helical Antenna with Feed-Through Insulator for High-Power Microwave Applications

    Get PDF
    In this paper, a novel helical antenna for high-power microwave is proposed. The proposed antenna is intended to demonstrate improved power handling capacity without any deterioration in matching characteristics, gain, and axial ratio. The proposed antenna with a long helix structure is investigated in order to achieve high gain and a relatively wide impedance bandwidth. By increasing the distance between the helix and the ground plane, an improved power handling capacity is obtained, and the impedance matching problem caused by the proposed method is addressed with the use of a feed-through insulator. In addition, a conical-shaped ground is used to compensate for the gain reduction by increasing the distance between the helix and the ground plane. As a result, the proposed antenna exhibits a gain exceeding 11 dBi and an axial ratio of less than 2 dB within the frequency range of 0.86–1.09 GHz. In addition, its power handling capacity exceeds 50 MW for a 0.7-ns input pulse length in air conditions

    Delayed Diagnosis of an Intraurethral Foreign Body Causing Urosepsis and Penile Necrosis

    Get PDF
    Cases of self-inserted foreign bodies in the male urethra and urinary bladder are unusual. In most cases, the type of foreign body can be identified by taking a history or from radiological findings; sometimes, however, it is difficult to identify the foreign body because of decreased mental capacity of the patient or unknown radiological characteristics of the foreign body. We experienced a chronic alcoholic patient with septicemia and penile necrosis in whom a fragment of mirror glass had passed through the urethra into the bladder. The glass, 2 cm in length and 0.7 cm in diameter, was detected by cystoscopy and was removed by using a resectosope
    corecore