54 research outputs found

    Inter-rater reliability, sensitivity to change and responsiveness of the orthopaedic Wolf-Motor-Function-Test as functional capacity measure before and after rehabilitation in patients with proximal humeral fractures

    Get PDF
    Background: The incidence of proximal humeral fractures (PHF) increased by more than 30% over the last decade, which is accompanied by an increased number of operations. However, the evidence on operative vs. non-operative treatment and post-operative treatments is limited and mostly based on expert opinion. It is mandatory to objectively assess functional capacity to compare different treatments. Clinical tools should be valid, reliable and sensitive to change assessing functional capacity after PHFs. This study aimed to analyse inter-rater reliability of the videotaped Wolf-Motor-Function-Test-Orthopaedic (WMFT-O) and the association between the clinical WMFT-O and the Disability of the Arm, Shoulder and Hand (DASH) and to determine the sensitivity to change of the WMFT-O and the DASH to measure functional capacity before and after rehabilitation in PHF patients. Methods: Fifty-six patients (61.7 ± 14.7 years) after surgical treatment of PHF were assessed using the WMFT-O at two different time points. To determine inter-rater reliability, the videotaped WMFT-O was evaluated through three blinded raters. Inter-rater agreement was determined by Fleiss’ Kappa statistics. Pearson correlation coefficients were calculated to assess the association between the clinical WMFT-O and the video rating as well as the DASH. Sensitivity to change and responsiveness were analysed for the WMFT-O and the DASH in a subsample of forty patients (53.8 ± 1.4 years) who were assessed before and after a three week robotic-assisted training intervention. Results: Inter-rater agreement was indicated by Fleiss’ Kappa values ranging from 0.33–0.66 for functional capacity and from 0.27–0.54 for quality of movement. The correlation between the clinical WMFT-O and the video rating was higher than 0.77. The correlation between the clinical WMFT-O and the DASH was weak. Sensitivity to change was high for the WMFT-O and the DASH and responsiveness was given. In comparison to the DASH, the sensitivity to change of the WMFT-O was higher. Conclusion: The overall results indicate that the WMFT-O is a reliable, sensitive and responsive instrument to measure more objectively functional change over time in rehabilitation after PHF. Furthermore, it has been shown that video assessment is eligible for studies to ensure a full blinding of raters. Trial registration: Clinicaltrials.gov, NCT03100201. Registered on 28 March 2017. The trial was retrospectively registered

    Validation of Accuracy of SVM-Based Fall Detection System Using Real-World Fall and Non-Fall Datasets

    Get PDF
    Falls are a major cause of injuries and deaths in older adults. Even when no injury occurs, about half of all older adults who fall are unable to get up without assistance. The extended period of lying on the floor often leads to medical complications, including muscle damage, dehydration, anxiety and fear of falling. Wearable sensor systems incorporating accelerometers and/or gyroscopes are designed to prevent long lies by automatically detecting and alerting care providers to the occurrence of a fall. Research groups have reported up to 100% accuracy in detecting falls in experimental settings. However, there is a lack of studies examining accuracy in the real-world setting. In this study, we examined the accuracy of a fall detection system based on real-world fall and non-fall data sets. Five young adults and 19 older adults went about their daily activities while wearing tri-axial accelerometers. Older adults experienced 10 unanticipated falls during the data collection. Approximately 400 hours of activities of daily living were recorded. We employed a machine learning algorithm, Support Vector Machine (SVM) classifier, to identify falls and non-fall events. We found that our system was able to detect 8 out of the 10 falls in older adults using signals from a single accelerometer (waist or sternum). Furthermore, our system did not report any false alarm during approximately 28.5 hours of recorded data from young adults. However, with older adults, the false positive rate among individuals ranged from 0 to 0.3 false alarms per hour. While our system showed higher fall detection and substantially lower false positive rate than the existing fall detection systems, there is a need for continuous efforts to collect real-world data within the target population to perform fall validation studies for fall detection systems on bigger real-world fall and non-fall datasets

    A quality control check to ensure comparability of stereophotogrammetric data between session and systems

    Get PDF
    Optoelectronic stereophotogrammetric (SP) systems are widely used in human movement research for clinical diagnostics, interventional applications, and as a reference system for validating alternative technologies. Regardless of the application, SP systems exhibit different random and systematic errors depending on camera specifications, system setup and laboratory environment, which hinders comparing SP data between sessions and across different systems. While many methods have been proposed to quantify and report the errors of SP systems, they are rarely utilized due to their complexity and need for additional equipment. In response, an easy-to-use quality control (QC) check has been designed that can be completed immediately prior to a data collection. This QC check requires minimal training for the operator and no additional equipment. In addition, a custom graphical user interface ensures automatic processing of the errors in an easy-to-read format for immediate interpretation. On initial deployment in a multicentric study, the check (i) proved to be feasible to perform in a short timeframe with minimal burden to the operator, and (ii) quantified the level of random and systematic errors between sessions and systems, ensuring comparability of data in a variety of protocol setups, including repeated measures, longitudinal studies and multicentric studies

    Electronic Quantum Coherence in Glycine Molecules Probed with Ultrashort X-ray Pulses in Real Time

    Full text link
    Structural changes in nature and technology are driven by charge carrier motion. A process such as charge-directed reactivity that can be operational in radiobiology is more efficient, if energy transfer and charge motion proceeds along well-defined quantum mechanical pathways keeping the coherence and minimizing dissipation. The open question is: do long-lived electronic quantum coherences exist in complex molecules? Here, we use x-rays to create and monitor electronic wave packets in the amino acid glycine. The outgoing photoelectron wave leaves behind a positive charge formed by a superposition of quantum mechanical eigenstates. Delayed x-ray pulses track the induced electronic coherence through the photoelectron emission from the sequential double photoionization processes. The observed sinusoidal modulation of the detected electron yield as a function of time clearly demonstrates that electronic quantum coherence is preserved for at least 25 femtoseconds in this molecule of biological relevance. The surviving coherence is detected via the dominant sequential double ionization channel, which is found to exhibit a phase shift as a function of the photoelectron energy. The experimental results agree with advanced ab-initio simulations.Comment: 54 pages, 11 figure

    Acceptability of wearable devices for measuring mobility remotely: Observations from the Mobilise-D technical validation study

    Get PDF
    Background This study aimed to explore the acceptability of a wearable device for remotely measuring mobility in the Mobilise-D technical validation study (TVS), and to explore the acceptability of using digital tools to monitor health. Methods Participants (N = 106) in the TVS wore a waist-worn device (McRoberts Dynaport MM + ) for one week. Following this, acceptability of the device was measured using two questionnaires: The Comfort Rating Scale (CRS) and a previously validated questionnaire. A subset of participants (n = 36) also completed semi-structured interviews to further determine device acceptability and to explore their opinions of the use of digital tools to monitor their health. Questionnaire results were analysed descriptively and interviews using a content analysis. Results The device was considered both comfortable (median CRS (IQR; min-max) = 0.0 (0.0; 0–20) on a scale from 0–20 where lower scores signify better comfort) and acceptable (5.0 (0.5; 3.0–5.0) on a scale from 1–5 where higher scores signify better acceptability). Interviews showed it was easy to use, did not interfere with daily activities, and was comfortable. The following themes emerged from participants’ as being important to digital technology: altered expectations for themselves, the use of technology, trust, and communication with healthcare professionals. Conclusions Digital tools may bridge existing communication gaps between patients and clinicians and participants are open to this. This work indicates that waist-worn devices are supported, but further work with patient advisors should be undertaken to understand some of the key issues highlighted. This will form part of the ongoing work of the Mobilise-D consortium

    An Algorithm for Accurate Marker-Based Gait Event Detection in Healthy and Pathological Populations During Complex Motor Tasks

    Get PDF
    There is growing interest in the quantification of gait as part of complex motor tasks. This requires gait events (GEs) to be detected under conditions different from straight walking. This study aimed to propose and validate a new marker-based GE detection method, which is also suitable for curvilinear walking and step negotiation. The method was first tested against existing algorithms using data from healthy young adults (YA, n = 20) and then assessed in data from 10 individuals from the following five cohorts: older adults, chronic obstructive pulmonary disease, multiple sclerosis, Parkinson’s disease, and proximal femur fracture. The propagation of the errors associated with GE detection on the calculation of stride length, duration, speed, and stance/swing durations was investigated. All participants performed a variety of motor tasks including curvilinear walking and step negotiation, while reference GEs were identified using a validated methodology exploiting pressure insole signals. Sensitivity, positive predictive values (PPV), F1-score, bias, precision, and accuracy were calculated. Absolute agreement [intraclass correlation coefficient (ICC2,1)] between marker-based and pressure insole stride parameters was also tested. In the YA cohort, the proposed method outperformed the existing ones, with sensitivity, PPV, and F1 scores ≄ 99% for both GEs and conditions, with a virtually null bias (<10 ms). Overall, temporal inaccuracies minimally impacted stride duration, length, and speed (median absolute errors ≀1%). Similar algorithm performances were obtained for all the other five cohorts in GE detection and propagation to the stride parameters, where an excellent absolute agreement with the pressure insoles was also found (ICC2,1=0.817− 0.999). In conclusion, the proposed method accurately detects GE from marker data under different walking conditions and for a variety of gait impairments

    Connecting real-world digital mobility assessment to clinical outcomes for regulatory and clinical endorsement–the Mobilise-D study protocol

    Get PDF
    Background: The development of optimal strategies to treat impaired mobility related to ageing and chronic disease requires better ways to detect and measure it. Digital health technology, including body worn sensors, has the potential to directly and accurately capture real-world mobility. Mobilise-D consists of 34 partners from 13 countries who are working together to jointly develop and implement a digital mobility assessment solution to demonstrate that real-world digital mobility outcomes have the potential to provide a better, safer, and quicker way to assess, monitor, and predict the efficacy of new interventions on impaired mobility. The overarching objective of the study is to establish the clinical validity of digital outcomes in patient populations impacted by mobility challenges, and to support engagement with regulatory and health technology agencies towards acceptance of digital mobility assessment in regulatory and health technology assessment decisions. Methods/design: The Mobilise-D clinical validation study is a longitudinal observational cohort study that will recruit 2400 participants from four clinical cohorts. The populations of the Innovative Medicine Initiative-Joint Undertaking represent neurodegenerative conditions (Parkinson’s Disease), respiratory disease (Chronic Obstructive Pulmonary Disease), neuro-inflammatory disorder (Multiple Sclerosis), fall-related injuries, osteoporosis, sarcopenia, and frailty (Proximal Femoral Fracture). In total, 17 clinical sites in ten countries will recruit participants who will be evaluated every six months over a period of two years. A wide range of core and cohort specific outcome measures will be collected, spanning patient-reported, observer-reported, and clinician-reported outcomes as well as performance-based outcomes (physical measures and cognitive/mental measures). Daily-living mobility and physical capacity will be assessed directly using a wearable device. These four clinical cohorts were chosen to obtain generalizable clinical findings, including diverse clinical, cultural, geographical, and age representation. The disease cohorts include a broad and heterogeneous range of subject characteristics with varying chronic care needs, and represent different trajectories of mobility disability. Discussion: The results of Mobilise-D will provide longitudinal data on the use of digital mobility outcomes to identify, stratify, and monitor disability. This will support the development of widespread, cost-effective access to optimal clinical mobility management through personalised healthcare. Further, Mobilise-D will provide evidence-based, direct measures which can be endorsed by regulatory agencies and health technology assessment bodies to quantify the impact of disease-modifying interventions on mobility. Trial registration: ISRCTN12051706

    Design and validation of a multi-task, multi-context protocol for real-world gait simulation

    Get PDF
    Background: Measuring mobility in daily life entails dealing with confounding factors arising from multiple sources, including pathological characteristics, patient specific walking strategies, environment/context, and purpose of the task. The primary aim of this study is to propose and validate a protocol for simulating real-world gait accounting for all these factors within a single set of observations, while ensuring minimisation of participant burden and safety. Methods: The protocol included eight motor tasks at varying speed, incline/steps, surface, path shape, cognitive demand, and included postures that may abruptly alter the participants’ strategy of walking. It was deployed in a convenience sample of 108 participants recruited from six cohorts that included older healthy adults (HA) and participants with potentially altered mobility due to Parkinson’s disease (PD), multiple sclerosis (MS), proximal femoral fracture (PFF), chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF). A novelty introduced in the protocol was the tiered approach to increase difficulty both within the same task (e.g., by allowing use of aids or armrests) and across tasks. Results: The protocol proved to be safe and feasible (all participants could complete it and no adverse events were recorded) and the addition of the more complex tasks allowed a much greater spread in walking speeds to be achieved compared to standard straight walking trials. Furthermore, it allowed a representation of a variety of daily life relevant mobility aspects and can therefore be used for the validation of monitoring devices used in real life. Conclusions: The protocol allowed for measuring gait in a variety of pathological conditions suggests that it can also be used to detect changes in gait due to, for example, the onset or progression of a disease, or due to therapy. Trial registration: ISRCTN—12246987

    Technical validation of real-world monitoring of gait: a multicentric observational study

    Get PDF
    Introduction: Existing mobility endpoints based on functional performance, physical assessments and patient self-reporting are often affected by lack of sensitivity, limiting their utility in clinical practice. Wearable devices including inertial measurement units (IMUs) can overcome these limitations by quantifying digital mobility outcomes (DMOs) both during supervised structured assessments and in real-world conditions. The validity of IMU-based methods in the real- world, however, is still limited in patient populations. Rigorous validation procedures should cover the device metrological verification, the validation of the algorithms for the DMOs computation specifically for the population of interest and in daily life situations, and the users’ perspective on the device. Methods and analysis: This protocol was designed to establish the technical validity and patient acceptability of the approach used to quantify digital mobility in the real world by Mobilise-D, a consortium funded by the European Union (EU) as part of the Innovative Medicine Initiative, aiming at fostering regulatory approval and clinical adoption of DMOs. After defining the procedures for the metrological verification of an IMU-based device, the experimental procedures for the validation of algorithms used to calculate the DMOs are presented. These include laboratory and real-world assessment in 120 participants from five groups: healthy older adults; chronic obstructive pulmonary disease, Parkinson’s disease, multiple sclerosis, proximal femoral fracture and congestive heart failure. DMOs extracted from the monitoring device will be compared with those from different reference systems, chosen according to the contexts of observation. Questionnaires and interviews will evaluate the users’ perspective on the deployed technology and relevance of the mobility assessment. Ethics and dissemination: The study has been granted ethics approval by the centre’s committees (London—Bloomsbury Research Ethics committee; Helsinki Committee, Tel Aviv Sourasky Medical Centre; Medical Faculties of The University of TĂŒbingen and of the University of Kiel). Data and algorithms will be made publicly available
    • 