301 research outputs found

    Man, Meaning and History

    Get PDF
    Indonesi

    Perceived sounds and their reported level of disturbance in intensive care units: A multinational survey among healthcare professionals

    Get PDF
    The noise levels in intensive care units have been repeatedly reported to exceed the recommended guidelines and yield negative health outcomes among healthcare professionals. However, it is unclear which sound sources within this environment are perceived as disturbing. Therefore, this study aimed to evaluate how healthcare professionals in Germany, Switzerland, and Austria perceive the sound levels and the associated sound sources within their work environment and explore sound reduction strategies.; An online survey was conducted among 350 healthcare professionals working in intensive care units. The survey consisted of items on demographic and hospital data and questions about the perception of the sound levels [1 (strongly disagree) to 5 (strongly agree)], disturbance from sound sources [1 (not disturbing at all) to 5 (very disturbing)], and implementation potential, feasibility, and motivation to reduce sound reduction measures [1 (not high at all) to 5 (very high)].; Approximately 69.3% of the healthcare professionals perceived the sound levels in the ICUs as too high. Short-lasting human sounds (e.g. moans or laughs) [mean (M) ± standard deviation (SD) = 3.30 ± 0.81], devices and alarms (M ± SD = 2.67 ± 0.59), and short-lasting object sounds (M ± SD = 2.55 ± 0.68) were perceived as the most disturbing sounds. Reducing medical equipment alarms was considered to have greater implementation potential [M ± SD = 3.62 ± 0.92, t(334) = -7.30, p < 0.001], feasibility [M ± SD = 3.19 ± 0.93, t(334) = -11.02, p < 0.001], and motivation [M ± SD = 3.85 ± 0.89, t(334) = -10.10, p < 0.001] for reducing the sound levels.; This study showed that healthcare professionals perceive short-lasting human sounds as most disturbing and rated reducing medical equipment alarms as the best approach to reduce the sound levels in terms of potential, feasibility, and motivation for implementation

    Muscular myostatin gene expression and plasma concentrations are decreased in critically ill patients.

    Get PDF
    BACKGROUND The objective was to investigate the role of gene expression and plasma levels of the muscular protein myostatin in intensive care unit-acquired weakness (ICUAW). This was performed to evaluate a potential clinical and/or pathophysiological rationale of therapeutic myostatin inhibition. METHODS A retrospective analysis from pooled data of two prospective studies to assess the dynamics of myostatin plasma concentrations (day 4, 8 and 14) and myostatin gene (MSTN) expression levels in skeletal muscle (day 15) was performed. Associations of myostatin to clinical and electrophysiological outcomes, muscular metabolism and muscular atrophy pathways were investigated. RESULTS MSTN gene expression (median [IQR] fold change: 1.00 [0.68-1.54] vs. 0.26 [0.11-0.80]; p = 0.004) and myostatin plasma concentrations were significantly reduced in all critically ill patients when compared to healthy controls. In critically ill patients, myostatin plasma concentrations increased over time (median [IQR] fold change: day 4: 0.13 [0.08/0.21] vs. day 8: 0.23 [0.10/0.43] vs. day 14: 0.40 [0.26/0.61]; p < 0.001). Patients with ICUAW versus without ICUAW showed significantly lower MSTN gene expression levels (median [IQR] fold change: 0.17 [0.10/0.33] and 0.51 [0.20/0.86]; p = 0.047). Myostatin levels were directly correlated with muscle strength (correlation coefficient 0.339; p = 0.020) and insulin sensitivity index (correlation coefficient 0.357; p = 0.015). No association was observed between myostatin plasma concentrations as well as MSTN expression levels and levels of mobilization, electrophysiological variables, or markers of atrophy pathways. CONCLUSION Muscular gene expression and systemic protein levels of myostatin are downregulated during critical illness. The previously proposed therapeutic inhibition of myostatin does therefore not seem to have a pathophysiological rationale to improve muscle quality in critically ill patients. TRIAL REGISTRATION ISRCTN77569430 -13th of February 2008 and ISRCTN19392591 17th of February 2011

    Electrocautery smoke exposure and efficacy of smoke evacuation systems in minimally invasive and open surgery: a prospective randomized study.

    Get PDF
    Worldwide, health care professionals working in operating rooms (ORs) are exposed to electrocautery smoke on a daily basis. Aims of this study were to determine composition and concentrations of electrocautery smoke in the OR using mass spectrometry. Prospective observational study at a tertiary care academic center, involving 122 surgical procedures of which 84 were 1:1 computer randomized to smoke evacuation system (SES) versus no SES use. Irritating, toxic, carcinogenic and mutagenic VOCs were observed in OR air, with some exceeding permissible exposure limits (OSHA/NIOSH). Mean total concentration of harmful compounds was 272.69 ppb (± 189 ppb) with a maximum total concentration of harmful substances of 8991 ppb (at surgeon level, no SES). Maximum total VOC concentrations were 1.6 ± 1.2 ppm (minimally-invasive surgery) and 2.1 ± 1.5 ppm (open surgery), and total maximum VOC concentrations were 1.8 ± 1.3 ppm at the OR table 'at surgeon level' and 1.4 ± 1.0 ppm 'in OR room air' away from the operating table. Neither difference was statistically significant. In open surgery, SES significantly reduced maximum concentrations of specific VOCs at surgeon level, including aromatics and aldehydes. Our data indicate relevant exposure of health care professionals to volatile organic compounds in the OR. Surgical technique and distance to cautery devices did not significantly reduce exposure. SES reduced exposure to specific harmful VOC's during open surgery.Trial Registration Number: NCT03924206 (clinicaltrials.gov)

    Development and early diagnosis of critical illness myopathy in COVID-19 associated acute respiratory distress syndrome.

    Get PDF
    BACKGROUND The COVID-19 pandemic has greatly increased the incidence and clinical importance of critical illness myopathy (CIM), because it is one of the most common complications of modern intensive care medicine. Current diagnostic criteria only allow diagnosis of CIM at an advanced stage, so that patients are at risk of being overlooked, especially in early stages. To determine the frequency of CIM and to assess a recently proposed tool for early diagnosis, we have followed a cohort of COVID-19 patients with acute respiratory distress syndrome and compared the time course of muscle excitability measurements with the definite diagnosis of CIM. METHODS Adult COVID-19 patients admitted to the Intensive Care Unit of the University Hospital Bern, Switzerland requiring mechanical ventilation were recruited and examined on Days 1, 2, 5, and 10 post-intubation. Clinical examination, muscle excitability measurements, medication record, and laboratory analyses were performed on all study visits, and additionally nerve conduction studies, electromyography and muscle biopsy on Day 10. Muscle excitability data were compared with a cohort of 31 age-matched healthy subjects. Diagnosis of definite CIM was made according to the current guidelines and was based on patient history, results of clinical and electrophysiological examinations as well as muscle biopsy. RESULTS Complete data were available in 31 out of 44 recruited patients (mean [SD] age, 62.4 [9.8] years). Of these, 17 (55%) developed CIM. Muscle excitability measurements on Day 10 discriminated between patients who developed CIM and those who did not, with a diagnostic precision of 90% (AUC 0.908; 95% CI 0.799-1.000; sensitivity 1.000; specificity 0.714). On Days 1 and 2, muscle excitability parameters also discriminated between the two groups with 73% (AUC 0.734; 95% CI 0.550-0.919; sensitivity 0.562; specificity 0.857) and 82% (AUC 0.820; CI 0.652-0.903; sensitivity 0.750; specificity 0.923) diagnostic precision, respectively. All critically ill COVID-19 patients showed signs of muscle membrane depolarization compared with healthy subjects, but in patients who developed CIM muscle membrane depolarization on Days 1, 2 and 10 was more pronounced than in patients who did not develop CIM. CONCLUSIONS This study reports a 55% prevalence of definite CIM in critically ill COVID-19 patients. Furthermore, the results confirm that muscle excitability measurements may serve as an alternative method for CIM diagnosis and support its use as a tool for early diagnosis and monitoring the development of CIM

    Noninvasive ventilation in COVID-19 patients aged ≥ 70 years-a prospective multicentre cohort study.

    Get PDF
    BACKGROUND Noninvasive ventilation (NIV) is a promising alternative to invasive mechanical ventilation (IMV) with a particular importance amidst the shortage of intensive care unit (ICU) beds during the COVID-19 pandemic. We aimed to evaluate the use of NIV in Europe and factors associated with outcomes of patients treated with NIV. METHODS This is a substudy of COVIP study-an international prospective observational study enrolling patients aged ≥ 70 years with confirmed COVID-19 treated in ICU. We enrolled patients in 156 ICUs across 15 European countries between March 2020 and April 2021.The primary endpoint was 30-day mortality. RESULTS Cohort included 3074 patients, most of whom were male (2197/3074, 71.4%) at the mean age of 75.7 years (SD 4.6). NIV frequency was 25.7% and varied from 1.1 to 62.0% between participating countries. Primary NIV failure, defined as need for endotracheal intubation or death within 30 days since ICU admission, occurred in 470/629 (74.7%) of patients. Factors associated with increased NIV failure risk were higher Sequential Organ Failure Assessment (SOFA) score (OR 3.73, 95% CI 2.36-5.90) and Clinical Frailty Scale (CFS) on admission (OR 1.46, 95% CI 1.06-2.00). Patients initially treated with NIV (n = 630) lived for 1.36 fewer days (95% CI - 2.27 to - 0.46 days) compared to primary IMV group (n = 1876). CONCLUSIONS Frequency of NIV use varies across European countries. Higher severity of illness and more severe frailty were associated with a risk of NIV failure among critically ill older adults with COVID-19. Primary IMV was associated with better outcomes than primary NIV. Clinical Trial Registration NCT04321265 , registered 19 March 2020, https://clinicaltrials.gov

    Paricalcitol reduces oxidative stress and inflammation in hemodialysis patients

    Get PDF
    Background: Treatment with selective vitamin D receptor activators such as paricalcitol have been shown to exert an anti-inflammatory effect in patients on hemodialysis, in addition to their action on mineral metabolism and independently of parathyroid hormone (PTH) levels. The objective of this study was to evaluate the additional antioxidant capacity of paricalcitol in a clinical setting. Methods: The study included 19 patients with renal disease on hemodialysis, of whom peripheral blood was obtained for analysis at baseline and three months after starting intravenous paricalcitol treatment. The following oxidizing and inflammatory markers were quantified: malondialdehyde (MDA), nitrites and carbonyl groups, indoleamine 2,3-dioxygenase (IDO), tumor necrosis factor alfa (TNF-α), interleukin-6 (IL-6), interleukin-18 (IL-18) and C-reactive protein (CRP). Of the antioxidants and anti-inflammatory markers, superoxide dismutase (SOD), catalase, reduced glutathione (GSH), thioredoxin, and interleukin-10 (IL-10) levels were obtained. Results: Baseline levels of oxidation markers MDA, nitric oxide and protein carbonyl groups significantly decreased after three months on paricalcitol treatment, while levels of GSH, thioredoxin, catalase and SOD activity significantly increased. After paricalcitol treatment, levels of the inflammatory markers CRP, TNF-α, IL-6 and IL-18 were significantly reduced in serum and the level of anti-inflammatory cytokine IL-10 was increased. Conclusions: In renal patients undergoing hemodialysis, paricalcitol treatment significantly reduces oxidative stress and inflammation, two well known factors leading to cardiovascular damageBackground: Treatment with selective vitamin D receptor activators such as paricalcitol have been shown to exert an anti-inflammatory effect in patients on hemodialysis, in addition to their action on mineral metabolism and independently of parathyroid hormone (PTH) levels. The objective of this study was to evaluate the additional antioxidant capacity of paricalcitol in a clinical setting. Methods: The study included 19 patients with renal disease on hemodialysis, of whom peripheral blood was obtained for analysis at baseline and three months after starting intravenous paricalcitol treatment. The following oxidizing and inflammatory markers were quantified: malondialdehyde (MDA), nitrites and carbonyl groups, indoleamine 2,3-dioxygenase (IDO), tumor necrosis factor alfa (TNF-α), interleukin-6 (IL-6), interleukin-18 (IL-18) and C-reactive protein (CRP). Of the antioxidants and anti-inflammatory markers, superoxide dismutase (SOD), catalase, reduced glutathione (GSH), thioredoxin, and interleukin-10 (IL-10) levels were obtained. Results: Baseline levels of oxidation markers MDA, nitric oxide and protein carbonyl groups significantly decreased after three months on paricalcitol treatment, while levels of GSH, thioredoxin, catalase and SOD activity significantly increased. After paricalcitol treatment, levels of the inflammatory markers CRP, TNF-α, IL-6 and IL-18 were significantly reduced in serum and the level of anti-inflammatory cytokine IL-10 was increased. Conclusions: In renal patients undergoing hemodialysis, paricalcitol treatment significantly reduces oxidative stress and inflammation, two well known factors leading to cardiovascular damage

    Methods for Measuring and Identifying Sounds in the Intensive Care Unit

    Get PDF
    BackgroundDespite many studies in the field examining excessive noise in the intensive care unit, this issue remains an ongoing problem. A limiting factor in the progress of the field is the inability to draw conclusions across studies due to the different and poorly reported approaches used. Therefore, the first goal is to present a method for the general measurement of sound pressure levels and sound sources, with precise details and reasoning, such that future studies can use these procedures as a guideline. The two procedures used in the general method will outline how to record sound pressure levels and sound sources, using sound level meters and observers, respectively. The second goal is to present the data collected using the applied method to show the feasibility of the general method and provide results for future reference.MethodsThe general method proposes the use of two different procedures for measuring sound pressure levels and sound sources in the intensive care unit. The applied method uses the general method to collect data recorded over 24-h, examining two beds in a four-bed room, via four sound level meters and four observers each working one at a time.ResultsThe interrater reliability of the different categories was found to have an estimate of &gt;0.75 representing good and excellent estimates, for 19 and 16 of the 24 categories, for the two beds examined. The equivalent sound pressure levels (LAeq) for the day, evening, and night shift, as an average of the sound level meters in the patient room, were 54.12, 53.37, and 49.05 dBA. In the 24-h measurement period, talking and human generated sounds occurred for a total of 495 (39.29% of the time) and 470 min (37.30% of the time), at the two beds of interest, respectively.ConclusionA general method was described detailing two independent procedures for measuring sound pressure levels and sound sources in the ICU. In a continuous data recording over 24 h, the feasibility of the proposed general method was confirmed. Moreover, good and excellent interrater reliability was achieved in most categories, making them suitable for future studies
    corecore