6,164 research outputs found

    Ultrastable CO2 Laser Trapping of Lithium Fermions

    Get PDF
    We demonstrate an ultrastable CO2 laser trap that provides tight confinement of neutral atoms with negligible optical scattering and minimal laser-noise- induced heating. Using this method, fermionic 6Li atoms are stored in a 0.4 mK deep well with a 1/e trap lifetime of 300 sec, consistent with a background pressure of 10^(-11) Torr. To our knowledge, this is the longest storage time ever achieved with an all-optical trap, comparable to the best reported magnetic traps.Comment: 4 pages using REVTeX, 1 eps figur

    Fourfold oscillations and anomalous magnetic irreversibility of magnetoresistance in the non-metallic regime of Pr1.85Ce0.15CuO4

    Full text link
    Using magnetoresistance measurements as a function of applied magnetic field and its direction of application, we present sharp angular-dependent magnetoresistance oscillations for the electron-doped cuprates in their low-temperature non-metallic regime. The presence of irreversibility in the magnetoresistance measurements and the related strong anisotropy of the field dependence for different in-plane magnetic field orientations indicate that magnetic domains play an important role for the determination of electronic properties. These domains are likely related to the stripe phase reported previously in hole-doped cuprates.Comment: 11 pages, 5 figure

    High-precision measurement of the half-life of 62^{62}Ga

    Full text link
    The beta-decay half-life of 62Ga has been studied with high precision using on-line mass separated samples. The decay of 62Ga which is dominated by a 0+ to 0+ transition to the ground state of 62Zn yields a half-life of T_{1/2} = 116.19(4) ms. This result is more precise than any previous measurement by about a factor of four or more. The present value is in agreement with older literature values, but slightly disagrees with a recent measurement. We determine an error weighted average value of all experimental half-lives of 116.18(4) ms.Comment: 9 pages, 5 figures, accepted for publication in PR

    Performance of a deterministic source of entangled photonic qubits

    Get PDF
    We study the possible limitations and sources of decoherence in the scheme for the deterministic generation of polarization-entangled photons, recently proposed by Gheri et al. [K. M. Gheri et al., Phys. Rev. A 58, R2627 (1998)], based on an appropriately driven single atom trapped within an optical cavity. We consider in particular the effects of laser intensity fluctuations, photon losses, and atomic motion.Comment: 10 pages, 6 figure

    Antibiotic Resistance

    Get PDF
    Our poster discusses an overview of antibiotic resistance. It goes into detail about what it is, how it came to be, and what medical professionals can do in their attempt to prevent it, as well as the general public. It also discusses the impact the impact antibiotic resistance has had on pharmacy, as well as the science behind it. A few organizations working towards this problem, and who keep a close eye on this issue are mentioned as well. We also discuss the determinants of health, which is essentially what is being done about it politically, individually, and the health services provided. Our goal is to stress the importance of properly taking antibiotics, and the potential to prevent this problem from happening. We hope you take some insight behind this issue after reading, and sparks an interest in this topic.https://digitalcommons.cedarville.edu/public_health_posters/1020/thumbnail.jp

    Double-beta decay Q values of 130Te, 128Te, and 120Te

    Get PDF
    The double-beta decay Q values of 130Te, 128Te, and 120Te have been determined from parent-daughter mass differences measured with the Canadian Penning Trap mass spectrometer. The 132Xe-129Xe mass difference, which is precisely known, was also determined to confirm the accuracy of these results. The 130Te Q value was found to be 2527.01(32) keV which is 3.3 keV lower than the 2003 Atomic Mass Evaluation recommended value, but in agreement with the most precise previous measurement. The uncertainty has been reduced by a factor of 6 and is now significantly smaller than the resolution achieved or foreseen in experimental searches for neutrinoless double-beta decay. The 128Te and 120Te Q values were found to be 865.87(131) keV and 1714.81(125) keV, respectively. For 120Te, this reduction in uncertainty of nearly a factor of 8 opens up the possibility of using this isotope for sensitive searches for neutrinoless double-electron capture and electron capture with positron emission.Comment: 5 pages, 2 figures, submitted to Physical Review Letter

    Position-sensitive ion detection in precision Penning trap mass spectrometry

    Get PDF
    A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.Comment: 20 pages, 13 figure
    corecore