2,019 research outputs found

    Hypoxia induces dilated cardiomyopathy in the chick embryo: mechanism, intervention, and long-term consequences

    Get PDF
    Background: Intrauterine growth restriction is associated with an increased future risk for developing cardiovascular diseases. Hypoxia in utero is a common clinical cause of fetal growth restriction. We have previously shown that chronic hypoxia alters cardiovascular development in chick embryos. The aim of this study was to further characterize cardiac disease in hypoxic chick embryos. Methods: Chick embryos were exposed to hypoxia and cardiac structure was examined by histological methods one day prior to hatching (E20) and at adulthood. Cardiac function was assessed in vivo by echocardiography and ex vivo by contractility measurements in isolated heart muscle bundles and isolated cardiomyocytes. Chick embryos were exposed to vascular endothelial growth factor (VEGF) and its scavenger soluble VEGF receptor-1 (sFlt-1) to investigate the potential role of this hypoxia-regulated cytokine. Principal Findings: Growth restricted hypoxic chick embryos showed cardiomyopathy as evidenced by left ventricular (LV) dilatation, reduced ventricular wall mass and increased apoptosis. Hypoxic hearts displayed pump dysfunction with decreased LV ejection fractions, accompanied by signs of diastolic dysfunction. Cardiomyopathy caused by hypoxia persisted into adulthood. Hypoxic embryonic hearts showed increases in VEGF expression. Systemic administration of rhVEGF165 to normoxic chick embryos resulted in LV dilatation and a dose-dependent loss of LV wall mass. Lowering VEGF levels in hypoxic embryonic chick hearts by systemic administration of sFlt-1 yielded an almost complete normalization of the phenotype. Conclusions/Significance: Our data show that hypoxia causes a decreased cardiac performance and cardiomyopathy in chick embryos, involving a significant VEGF-mediated component. This cardiomyopathy persists into adulthood

    “I would rather be told than not know” - A qualitative study exploring parental views on identifying the future risk of childhood overweight and obesity during infancy

    Get PDF
    BACKGROUND: Risk assessment tools provide an opportunity to prevent childhood overweight and obesity through early identification and intervention to influence infant feeding practices. Engaging parents of infants is paramount for success however; the literature suggests there is uncertainty surrounding the use of such tools with concerns about stigmatisation, labelling and expressions of parental guilt. This study explores parents' views on identifying future risk of childhood overweight and obesity during infancy and communicating risk to parents. METHODS: Semi-structured qualitative interviews were conducted with 23 parents and inductive, interpretive and thematic analysis performed. RESULTS: Three main themes emerged from the data: 1) Identification of infant overweight and obesity risk. Parents were hesitant about health professionals identifying infant overweight as believed they would recognise this for themselves, in addition parents feared judgement from health professionals. Identification of future obesity risk during infancy was viewed positively however the use of a non-judgemental communication style was viewed as imperative. 2) Consequences of infant overweight. Parents expressed immediate anxieties about the impact of excess weight on infant ability to start walking. Parents were aware of the progressive nature of childhood obesity however, did not view overweight as a significant problem until the infant could walk as viewed this as a point when any excess weight would be lost due to increased energy expenditure. 3) Parental attributions of causality, responsibility, and control. Parents articulated a high level of personal responsibility for preventing and controlling overweight during infancy, which translated into self-blame. Parents attributed infant overweight to overfeeding however articulated a reluctance to modify infant feeding practices prior to weaning. CONCLUSION: This is the first study to explore the use of obesity risk tools in clinical practice, the findings suggest that identification, and communication of future overweight and obesity risk is acceptable to parents of infants. Despite this positive response, findings suggest that parents' acceptance to identification of risk and implementation of behaviour change is time specific. The apparent level of parental responsibility, fear of judgement and self-blame also highlights the importance of health professionals approach to personalised risk communication so feelings of self-blame are negated and stigmatisation avoided

    Reporting on covariate adjustment in randomised controlled trials before and after revision of the 2001 CONSORT statement: a literature review

    Get PDF
    <p>Abstract</p> <p>Objectives</p> <p>To evaluate the use and reporting of adjusted analysis in randomised controlled trials (RCTs) and compare the quality of reporting before and after the revision of the CONSORT Statement in 2001.</p> <p>Design</p> <p>Comparison of two cross sectional samples of published articles.</p> <p>Data Sources</p> <p>Journal articles indexed on PubMed in December 2000 and December 2006.</p> <p>Study Selection</p> <p>Parallel group RCTs with a full publication carried out in humans and published in English</p> <p>Main outcome measures</p> <p>Proportion of articles reported adjusted analysis; use of adjusted analysis; the reason for adjustment; the method of adjustment and the reporting of adjusted analysis results in the main text and abstract.</p> <p>Results</p> <p>In both cohorts, 25% of studies reported adjusted analysis (84/355 in 2000 vs 113/422 in 2006). Compared with articles reporting only unadjusted analyses, articles that reported adjusted analyses were more likely to specify primary outcomes, involve multiple centers, perform stratified randomization, be published in general medical journals, and recruit larger sample sizes. In both years a minority of articles explained why and how covariates were selected for adjustment (20% to 30%). Almost all articles specified the statistical methods used for adjustment (99% in 2000 vs 100% in 2006) but only 5% and 10%, respectively, reported both adjusted and unadjusted results as recommended in the CONSORT guidelines.</p> <p>Conclusion</p> <p>There was no evidence of change in the reporting of adjusted analysis results five years after the revision of the CONSORT Statement and only a few articles adhered fully to the CONSORT recommendations.</p

    Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine.

    Get PDF
    OBJECTIVE: Circulatory shock is a life-threatening syndrome resulting in multiorgan failure and a high mortality rate. The aim of this consensus is to provide support to the bedside clinician regarding the diagnosis, management and monitoring of shock. METHODS: The European Society of Intensive Care Medicine invited 12 experts to form a Task Force to update a previous consensus (Antonelli et al.: Intensive Care Med 33:575-590, 2007). The same five questions addressed in the earlier consensus were used as the outline for the literature search and review, with the aim of the Task Force to produce statements based on the available literature and evidence. These questions were: (1) What are the epidemiologic and pathophysiologic features of shock in the intensive care unit ? (2) Should we monitor preload and fluid responsiveness in shock ? (3) How and when should we monitor stroke volume or cardiac output in shock ? (4) What markers of the regional and microcirculation can be monitored, and how can cellular function be assessed in shock ? (5) What is the evidence for using hemodynamic monitoring to direct therapy in shock ? Four types of statements were used: definition, recommendation, best practice and statement of fact. RESULTS: Forty-four statements were made. The main new statements include: (1) statements on individualizing blood pressure targets; (2) statements on the assessment and prediction of fluid responsiveness; (3) statements on the use of echocardiography and hemodynamic monitoring. CONCLUSIONS: This consensus provides 44 statements that can be used at the bedside to diagnose, treat and monitor patients with shock
    corecore