505 research outputs found

    Clinical, genetic, neurophysiological and functional study of new mutations in episodic ataxia type 1.

    Get PDF
    Heterozygous mutations in KCNA1 cause episodic ataxia type 1 (EA1), an ion channel disorder characterised by brief paroxysms of cerebellar dysfunction and persistent neuromyotonia. This paper describes four previously unreported families with EA1, with the aim of understanding the phenotypic spectrum associated with different mutations

    Using an e-Health Intervention to Reduce Prolonged Sitting in UK Office Workers: A Randomised Acceptability and Feasibility Study

    Get PDF
    Low-cost workplace interventions are required to reduce prolonged sitting in office workers as this may improve employees’ health and well-being. This study aimed to assess the acceptability and feasibility of an e-health intervention to reduce prolonged sitting among sedentary UK-based office workers. Secondary aims were to describe preliminary changes in employee health, mood and work productivity after using an e-health intervention. Healthy, university office workers (n = 14) completed this study. An 8 week randomised crossover design was used, consisting of two trials: Intervention (computer-based prompts) and Control. Eligibility and retention rates were recorded to assess the feasibility of the trial and interviews were conducted following the intervention to explore its acceptability. Sitting, standing and stepping were objectively assessed prior to and during week 8 of each trial. Before and after each trial, measurements of vascular function, cerebrovascular function, mood and work productivity were obtained. This study had eligibility and retention rates of 54.5% and 77.8%, respectively. Participants expressed a lack of autonomy and disruption to their workflow when using the e-health intervention, raising concerns over its acceptability and long-term implementation. Preliminary data indicate that the intervention may improve the patterning of activity accrued during work hours, with increases in the number of standing and stepping bouts completed, in addition to improving vascular function. This e-health intervention is feasible to deliver in a cohort of university office workers. However, adaptations to its implementation, such as personalised settings, are needed to increase acceptability before larger trials can be conducted

    Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature

    Get PDF
    Joint arthroplasty registries show an increased rate of aseptic loosening in uncemented acetabular components as compared to cemented acetabular components. Since loosening is associated with particulate wear debris, we postulated that uncemented acetabular components demonstrate a higher polyethylene wear rate than cemented acetabular components in total hip arthroplasty. We performed a systematic review of the peer-reviewed literature, comparing the wear rate in uncemented and cemented acetabular components in total hip arthroplasty. Studies were identified using MEDLINE (PubMed), EMBASE and the Cochrane Central Register of Controlled Trials. Study quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. The search resulted in 425 papers. After excluding duplicates and selection based on title and abstracts, nine studies were found eligible for further analysis: two randomised controlled trials, and seven observational studies. One randomised controlled trial found a higher polyethylene wear rate in uncemented acetabular components, while the other found no differences. Three out of seven observational studies showed a higher polyethylene wear in uncemented acetabular component fixation; the other four studies did not show any differences in wear rates. The available evidence suggests that a higher annual wear rate may be encountered in uncemented acetabular components as compared to cemented components

    Genetic Diversity and Antimicrobial Resistance of Escherichia coli from Human and Animal Sources Uncovers Multiple Resistances from Human Sources

    Get PDF
    Escherichia coli are widely used as indicators of fecal contamination, and in some cases to identify host sources of fecal contamination in surface water. Prevalence, genetic diversity and antimicrobial susceptibility were determined for 600 generic E. coli isolates obtained from surface water and sediment from creeks and channels along the middle Santa Ana River (MSAR) watershed of southern California, USA, after a 12 month study. Evaluation of E. coli populations along the creeks and channels showed that E. coli were more prevalent in sediment compared to surface water. E. coli populations were not significantly different (P = 0.05) between urban runoff sources and agricultural sources, however, E. coli genotypes determined by pulsed-field gel electrophoresis (PFGE) were less diverse in the agricultural sources than in urban runoff sources. PFGE also showed that E. coli populations in surface water were more diverse than in the sediment, suggesting isolates in sediment may be dominated by clonal populations.Twenty four percent (144 isolates) of the 600 isolates exhibited resistance to more than one antimicrobial agent. Most multiple resistances were associated with inputs from urban runoff and involved the antimicrobials rifampicin, tetracycline, and erythromycin. The occurrence of a greater number of E. coli with multiple antibiotic resistances from urban runoff sources than agricultural sources in this watershed provides useful evidence in planning strategies for water quality management and public health protection

    Joint registry approach for identification of outlier prostheses

    Get PDF
    Background and purposeJoint Replacement Registries play a significant role in monitoring arthroplasty outcomes by publishing data on survivorship of individual prostheses or combinations of prostheses. The difference in outcomes can be device- or non-device-related, and these factors can be analyzed separately. Although registry data indicate that most prostheses have similar outcomes, some have a higher than anticipated rate of revision when compared to all other prostheses in their class. This report outlines how the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) has developed a method to report prostheses with a higher than expected rate of revision. These are referred to as "outlier" prostheses.Material and methodsSince 2004, the AOANJRR has developed a standardized process for identifying outliers. This is based on a 3-stage process consisting of an automated algorithm, an extensive analysis of individual prostheses or combinations by registry staff, and finally a meeting involving a panel from the Australian Orthopaedic Association Arthroplasty Society. Outlier prostheses are listed in the Annual Report as (1) identified but no longer used in Australia, (2) those that have been re-identified and that are still used, and (3) those that are being identified for the first time.Results78 prostheses or prosthesis combinations have been identified as being outliers using this approach (AOANJRR 2011 Annual Report). In addition, 5 conventional hip prostheses were initially identified, but after further analysis no longer met the defined criteria. 1 resurfacing hip prosthesis was initially identified, subsequently removed from the list, and then re-identified the following year when further data were available. All unicompartmental and primary total knee prostheses identified as having a higher than expected rate of revision have continued to be re-identified.InterpretationIt is important that registries use a transparent and accountable process to identify an outlier prosthesis. This paper describes the development, implementation, assessment, and impact of the approach used by the Australian Registry.Richard N de Steiger, Lisa N Miller, David C Davidson, Philip Ryan and Stephen E Grave

    Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: A report from the Norwegian Arthroplasty Register

    Get PDF
    Background and purpose: Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. Patients and methods: Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The 5 most common implants and the 3 most common navigation systems were selected. Cemented, uncemented, and hybrid knees were included. With the risk of revision for any cause as the primary endpoint and intraoperative complications and operating time as secondary outcomes, 1,465 computer-navigated knee replacements (CAS) and 8,214 conventionally operated knee replacements (CON) were compared. Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis, and ASA category were used. Results: Kaplan-Meier estimated survival at 2 years was 98% (95% CI: 97.5–98.3) in the CON group and 96% (95% CI: 95.0– 97.8) in the CAS group. The adjusted Cox regression analysis showed a higher risk of revision in the CAS group (RR = 1.7, 95% CI: 1.1–2.5; p = 0.02). The LCS Complete knee had a higher risk of revision with CAS than with CON (RR = 2.1, 95% CI: 1.3–3.4; p = 0.004)). The differences were not statistically significant for the other prosthesis brands. Mean operating time was 15 min longer in the CAS group. Interpretation: With the introduction of computer-navigated knee replacement surgery in Norway, the short-term risk of revision has increased for computer-navigated replacement with the LCS Complete. The mechanisms of failure of these implantations should be explored in greater depth, and in this study we have not been able to draw conclusions regarding causation

    Patellar tendon enthesis abnormalities and their association with knee pain and structural abnormalities in older adults

    Get PDF
    Objective: To describe associations between presence of patellar tendon enthesis (PTE) abnormalities and symptoms, structural abnormalities, and total knee replacement (TKR) in older adult cohort.Methods: PTE abnormalities (presence of abnormal bone signal and/or bone erosion), were measured on T2-weighted magnetic resonance (MR) images at baseline in 961 community-dwelling older adults. Knee pain and function limitation were assessed using Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Bone marrow lesions (BMLs), cartilage volume and defects score, and infrapatellar fat pad (IPFP) area were measured using validated methods. Incidence of TKR was determined by data linkage.Results: Participants with abnormal PTE bone signal and/or erosion was 20%. Cross-sectionally, presence of PTE abnormalities was associated with greater pain intensity while going up and down stairs (β = 0.22 (95% confidence interval (CI); 0.03, 0.41)), greater risk of femoral BMLs (RR = 1.46 (1.12, 1.90)) and worse tibial cartilage defects score (RR = 1.70 (1.16, 2.47), and smaller IPFP area (β = -0.27 (-0.47, -0.06) cm2), after adjustment of confounders. Longitudinally, presence of baseline PTE abnormalities was associated with a deleterious increase in tibial BML size (RR = 1.52 (1.12, 2.05)) over 10.7 years but not symptoms, other structural changes, or TKR.Conclusion: PTE abnormalities are common in older adults. Presence of cross-sectional but not longitudinal associations suggests they are commonly co-exist with other knee structural abnormalities but may not play a major role in symptom development or structural change, excepting tibial BMLs

    How do MRI-detected subchondral bone marrow lesions (BMLs) on two different MRI sequences correlate with clinically important outcomes?

    Get PDF
    The aim of this study is to describe the association of bone marrow lesions (BMLs) present on two different MRI sequences with clinical outcomes, cartilage defect progression, cartilage volume loss over 2.7 years, and total knee replacement (TKR) over 13.3 years. 394 participants (50-80 years) were assessed at baseline and 2.7 years. BML presence at baseline was scored on T1-weighted fat-suppressed 3D gradient-recalled acquisition (T1) and T2-weighted fat-suppressed 2D fast spin-echo (T2) sequences. Knee pain, function, and stiffness were assessed using WOMAC. Cartilage volume and defects were assessed using validated methods. Incident TKR was determined by data linkage. BMLs were mostly present on both MRI sequences (86%). BMLs present on T2, T1, and both sequences were associated with greater knee pain and functional limitation (odds ratio = 1.49 to 1.70; all p p p p p < 0.05). BMLs present on T2, T1, and both sequences were strongly associated with incident TKR. BMLs can be assessed on either T2- or T1-weighted sequences with no clinical predictive advantage of either sequence
    • …
    corecore