515 research outputs found

    Osteoid osteoma of the acetabular fossa: Five cases treated with percutaneous resection

    Get PDF
    SummaryBackgroundOsteoid osteoma is a painful benign osteogenic tumour for which the treatment objective is surgical resection of the nidus. The acetabular fossa is an uncommon site of involvement where surgical access can prove challenging.Materials and methodsWe report a case-series composed of five patients with osteoid osteoma of the acetabular fossa treated with percutaneous bone resection and drilling under computed tomography guidance.ResultsAll five patients had an uneventful postoperative course with immediate pain relief that was sustained over time.DiscussionThe outcomes achieved using our percutaneous technique compare favourably with those of other percutaneous methods, most notably regarding pain relief and patient tolerance of the procedure.ConclusionPercutaneous bone resection and drilling under computed tomography guidance proved effective for the treatment of osteoid osteoma involving the acetabular fossa.Level of evidenceLevel IV

    SPIROC (SiPM Integrated Read-Out Chip): Dedicated very front-end electronics for an ILC prototype hadronic calorimeter with SiPM read-out.

    No full text
    Omega et Calice collaborationsInternational audienceThe SPIROC chip is a dedicated very front-end electronics for an ILC prototype hadronic calorimeter with Silicon photomultiplier (or MPPC) readout. This ASIC is due to equip a 10,000-channel demonstrator in 2009. SPIROC is an evolution of FLC_SiPM used for the ILC AHCAL physics prototype [1]. SPIROC was submitted in June 2007 and will be tested in September 2007. It embeds cutting edge features that fulfil ILC final detector requirements. It has been realized in 0.35m SiGe technology. It has been developed to match the requirements of large dynamic range, low noise, low consumption, high precision and large number of readout channels needed. SPIROC is an auto-triggered, bi-gain, 36-channel ASIC which allows to measure on each channel the charge from one photoelectron to 2000 and the time with a 100ps accurate TDC. An analogue memory array with a depth of 16 for each channel is used to store the time information and the charge measurement. A 12-bit Wilkinson ADC has been embedded to digitize the analogue memory content (time and charge on 2 gains). The data are then stored in a 4kbytes RAM. A very complex digital part has been integrated to manage all theses features and to transfer the data to the DAQ which is described on [2]. After an exhaustive description, the extensive measurement results of that new front-end chip will be presented

    SPIROC (SiPM Integrated Read-Out Chip): Dedicated very front-end electronics for an ILC prototype hadronic calorimeter with SiPM read-out

    Get PDF
    The SPIROC chip is a dedicated very front-end electronics for an ILC prototype hadronic calorimeter with Silicon photomultiplier (or MPPC) readout. This ASIC is due to equip a 10,000-channel demonstrator in 2009. SPIROC is an evolution of FLC_SiPM used for the ILC AHCAL physics prototype [1]. SPIROC was submitted in June 2007 and will be tested in September 2007. It embeds cutting edge features that fulfil ILC final detector requirements. It has been realized in 0.35m SiGe technology. It has been developed to match the requirements of large dynamic range, low noise, low consumption, high precision and large number of readout channels needed. SPIROC is an auto-triggered, bi-gain, 36-channel ASIC which allows to measure on each channel the charge from one photoelectron to 2000 and the time with a 100ps accurate TDC. An analogue memory array with a depth of 16 for each channel is used to store the time information and the charge measurement. A 12-bit Wilkinson ADC has been embedded to digitize the analogue memory content (time and charge on 2 gains). The data are then stored in a 4kbytes RAM. A very complex digital part has been integrated to manage all theses features and to transfer the data to the DAQ which is described on [2]

    Spreading and fragmentation of particle-laden liquid sheets

    Full text link
    The fragmentation of liquid sheets produces a collection of droplets. The size distribution of the droplets has a considerable impact on the coating efficiency of sprays and the transport of contaminants. Although many processes commonly used particulate suspensions, the influence of the particles on the spreading dynamics of the sheet and its subsequent fragmentation has so far been considered negligible. In this paper, we consider experimentally a transient suspension sheet that expands radially. We characterize the influence of the particles on the dynamics of the liquid sheet and the fragmentation process. We highlight that the presence of particles modifies the thickness and reduces the stability of the liquid sheet. Our study suggests that particles can significantly modify the dynamics of liquid films through capillary effects, even for volume fractions much smaller than the maximum packing

    SPIROC (SiPM Integrated Read-Out Chip): Dedicated very front-end electronics for an ILC prototype hadronic calorimeter with SiPM read-out

    Get PDF
    The SPIROC chip is a dedicated very front-end electronics for an ILC prototype hadronic calorimeter with Silicon photomultiplier (or MPPC) readout. This ASIC is due to equip a 10,000-channel demonstrator in 2009. SPIROC is an evolution of FLC_SiPM used for the ILC AHCAL physics prototype [1]. SPIROC was submitted in June 2007 and will be tested in September 2007. It embeds cutting edge features that fulfil ILC final detector requirements. It has been realized in 0.35m SiGe technology. It has been developed to match the requirements of large dynamic range, low noise, low consumption, high precision and large number of readout channels needed. SPIROC is an auto-triggered, bi-gain, 36-channel ASIC which allows to measure on each channel the charge from one photoelectron to 2000 and the time with a 100ps accurate TDC. An analogue memory array with a depth of 16 for each channel is used to store the time information and the charge measurement. A 12-bit Wilkinson ADC has been embedded to digitize the analogue memory content (time and charge on 2 gains). The data are then stored in a 4kbytes RAM. A very complex digital part has been integrated to manage all theses features and to transfer the data to the DAQ which is described on [2]. After an exhaustive description, the extensive measurement results of that new front-end chip will be presented

    Spectra and Light Curves of Six Type Ia Supernovae at 0.511 < z < 1.12 and the Union2 Compilation

    Get PDF
    We report on work to increase the number of well-measured Type Ia supernovae (SNe Ia) at high redshifts. Light curves, including high signal-to-noise HST data, and spectra of six SNe Ia that were discovered during 2001 are presented. Additionally, for the two SNe with z>1, we present ground-based J-band photometry from Gemini and the VLT. These are among the most distant SNe Ia for which ground based near-IR observations have been obtained. We add these six SNe Ia together with other data sets that have recently become available in the literature to the Union compilation (Kowalski et al. 2008). We have made a number of refinements to the Union analysis chain, the most important ones being the refitting of all light curves with the SALT2 fitter and an improved handling of systematic errors. We call this new compilation, consisting of 557 supernovae, the Union2 compilation. The flat concordance LambdaCDM model remains an excellent fit to the Union2 data with the best fit constant equation of state parameter w=-0.997^{+0.050}_{-0.054} (stat) ^{+0.077}_{-0.082} (stat+sys\ together) for a flat universe, or w=-1.035^{+0.055}_{-0.059} (stat)^{+0.093}_{-0.097} (stat+sys together) with curvature. We also present improved constraints on w(z). While no significant change in w with redshift is detected, there is still considerable room for evolution in w. The strength of the constraints depend strongly on redshift. In particular, at z > 1, the existence and nature of dark energy are only weakly constrained by the data.Comment: 33 pages, 18 figures; accepted for publication in Astrophysical Journal. For data tables, code for cosmological analysis and full-resolution figures, see http://supernova.lbl.gov/Union

    The OPERA experiment Target Tracker

    Get PDF
    The main task of the Target Tracker detector of the long baseline neutrino oscillation OPERA experiment is to locate in which of the target elementary constituents, the lead/emulsion bricks, the neutrino interactions have occurred and also to give calorimetric information about each event. The technology used consists in walls of two planes of plastic scintillator strips, one per transverse direction. Wavelength shifting fibres collect the light signal emitted by the scintillator strips and guide it to both ends where it is read by multi-anode photomultiplier tubes. All the elements used in the construction of this detector and its main characteristics are described.Comment: 25 pages, submitted to Nuclear Instrument and Method

    Restframe I-band Hubble diagram for type Ia supernovae up to redshift z ~0.5

    Full text link
    We present a novel technique for fitting restframe I-band light curves on a data set of 42 Type Ia supernovae (SNe Ia). Using the result of the fit, we construct a Hubble diagram with 26 SNe from the subset at 0.01< z<0.1. Adding two SNe at z~0.5 yields results consistent with a flat Lambda-dominated``concordance universe'' (ΩM,ΩΛ\Omega_M,\Omega_\Lambda)=(0.25,0.75). For one of these, SN 2000fr, new near infrared data are presented. The high redshift supernova NIR data are also used to test for systematic effects in the use of SNe Ia as distance estimators. A flat, Lambda=0, universe where the faintness of supernovae at z~0.5 is due to grey dust homogeneously distributed in the intergalactic medium is disfavoured based on the high-z Hubble diagram using this small data-set. However, the uncertainties are large and no firm conclusion may be drawn. We explore the possibility of setting limits on intergalactic dust based on B-I and B-V colour measurements, and conclude that about 20 well measured SNe are needed to give statistically significant results. We also show that the high redshift restframe I-band data points are better fit by light curve templates that show a prominent second peak, suggesting that they are not intrinsically underluminous.Comment: Accepted for publication in A&A (01/04/2005

    The transformation of transport policy in Great Britain? 'New Realism' and New Labour's decade of displacement activity

    Get PDF
    In a 1999 paper, Goodwin announced ‘the transformation of transport policy in Great Britain’. His central point was that consensus was emerging among policy makers and academics based on earlier work including Transport: The New Realism, which rejected previous orthodoxy that the supply of road space could and should be continually expanded to match demand. Instead a combination of investment in public transport, walking and cycling opportunities and – crucially – demand management should form the basis of transport policy to address rising vehicle use and associated increases in congestion and pollution / carbon emissions. This thinking formed the basis of the 1997 Labour government’s ‘sustainable transport’ policy, but after 13 years in power ministers neither transformed policy nor tackled longstanding transport trends. Our main aim in this paper is to revisit the concept of New Realism and re-examine its potential utility as an agent of change in British transport policy. Notwithstanding the outcome of Labour’s approach to transport policy, we find that the central tenets of the New Realism remain robust and that the main barriers to change are related to broader political and governance issues which suppress radical policy innovation

    Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter

    Full text link
    We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.Comment: 35 pages, 21 figures, 8 table
    • 

    corecore