282 research outputs found

    Inhibition of release of inflammatory in primary and cultured cells by a Chinese herbal medicine formula for allergic rhinitis

    Get PDF
    BACKGROUND - We demonstrated that a Chinese herbal formula, which we refer to as RCM-101, developed from a traditional Chinese medicine formula, reduced nasal and non-nasal symptoms of seasonal allergic rhinitis (SAR). The present study in primary and cultured cells was undertaken to investigate the effects of RCM-101 on the production/release of inflammatory mediators known to be involved in SAR. METHODS - Compound 48/80-induced histamine release was studied in rat peritoneal mast cells. Production of leukotriene B4 induced by the calcium ionophore A23187 was studied in porcine neutrophils using an HPLC assay and lipopolysaccharide-stimulated prostaglandin E2 production was studied in murine macrophage (Raw 264.7) cells by immune-enzyme assay. Expression of cyclooxygenase-1 (COX-1) and cyclooxygenase-2 (COX-2) was determined in Raw 264.7 cells, using western blotting techniques. RESULTS - RCM-101 (1-100 microg/mL) produced concentration-dependent inhibition of compound 48/80-induced histamine release from rat peritoneal mast cells and of lipopolysaccharide-stimulated prostaglandin E2 release from Raw 264.7 cells. Over the range 1 - 10 microg/mL, it inhibited A23187-induced leukotriene B4 production in porcine neutrophils. In addition, RCM-101 (100 microg/mL) inhibited the expression of COX-2 protein but did not affect that of COX-1. CONCLUSION - The findings indicate that RCM-101 inhibits the release and/or synthesis of histamine, leukotriene B4 and prostaglandin E2 in cultured cells. These interactions of RCM-101 with multiple inflammatory mediators are likely to be related to its ability to reduce symptoms of allergic rhinitis

    First Narrow-Band Search For Continuous Gravitational Waves From Known Pulsars In Advanced Detector Data

    Get PDF
    In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector\u27s differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector\u27s gravitational-wave response. The gravitational-wave response model is determined by the detector\u27s opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz

    All-Sky Search For Periodic Gravitational Waves In The O1 Ligo Data

    Get PDF
    We present the results of a semicoherent search for continuous gravitational waves from the low-mass X-ray binary Scorpius X-1, using data from the first Advanced LIGO observing run. The search method uses details of the modelled, parametrized continuous signal to combine coherently data separated by less than a specified coherence time, which can be adjusted to trade off sensitivity against computational cost. A search was conducted over the frequency range from 25 Hz to 2000 Hz, spanning the current observationally-constrained range of the binary orbital parameters. No significant detection candidates were found, and frequency-dependent upper limits were set using a combination of sensitivity estimates and simulated signal injections. The most stringent upper limit was set at 175 Hz, with comparable limits set across the most sensitive frequency range from 100 Hz to 200 Hz. At this frequency, the 95 pct upper limit on signal amplitude h0 is 2.3e-25 marginalized over the unknown inclination angle of the neutron star\u27s spin, and 8.03e-26 assuming the best orientation (which results in circularly polarized gravitational waves). These limits are a factor of 3-4 stronger than those set by other analyses of the same data, and a factor of about 7 stronger than the best upper limits set using initial LIGO data. In the vicinity of 100 Hz, the limits are a factor of between 1.2 and 3.5 above the predictions of the torque balance model, depending on inclination angle, if the most likely inclination angle of 44 degrees is assumed, they are within a factor of 1.7

    Insect herbivores associated with Lycium ferocissimum (Solanaceae) in South Africa and their potential as biological control agents in Australia

    Get PDF
    Lycium ferocissimum Miers (Solanaceae) is an indigenous shrub in South Africa but has become invasive in several countries including Australia, where chemical and mechanical control methods have proved costly and unsustainable. In Australia, biological control is being considered as a management option, but the herbivorous insects associated with the plant in its native range are not well known. The aim of this study was to survey the phytophagous insects associated with L. ferocissimum in South Africa and prioritise promising biological control agents. In South Africa, the plant occurs in two geographically distinct areas, the Eastern and Western Cape provinces. Surveys for phytophagous insects on L. ferocissimum were carried out repeatedly over a two-year period in these two regions. The number of insect species found in the Eastern Cape Province (55) was higher than that in the WesternCapeProvince (41), but insect diversity based on Shannon indices was highest in the Western Cape Province. Indicator species analysis revealed eight insect herbivore species driving the differences in the herbivore communities between the two provinces. Based on insect distribution, abundance, feeding preference and available literature, three species were prioritised as potential biological control agents. These include the leaf-chewing beetles Cassida distinguenda Spaeth (Chrysomelidae) and Cleta eckloni Mulsant (Coccinellidae) and the leaf-mining weevil Neoplatygaster serietuberculata Gyllenhal (Curculionidae)

    Development of an instrument to assess to quality of acupuncture: results from a Delphi process

    Get PDF
    Background: Quality acupuncture influences the outcomes of clinical research, and issues associated with effective administration of acupuncture in randomized controlled trials need to be addressed when appraising studies. Objective: The study objective was to achieve consensus on domains and items for inclusion in a rating scale to assess quality acupuncture administered in clinical research. Study design and subjects: An active group of Australian acupuncture researchers initially identified a pool of items assessing quality. The Delphi consensus process was then used to select and reduce the number of items, and an additional expert panel of 42 researchers were invited to participate. Participants initially ranked items along a five-point scale for the first Delphi round, and indicated an agree or disagree response during the second round. For an item to be retained into the second round, an item had to attain greater than 80% agreement that the item described a dimension of quality acupuncture and related study design. Results: Thirty-two (32) experts agreed to participate in the study. After two rounds of the Delphi process, consensus was reached on 14 domains and 26 items relating to quality acupuncture. Domains, items, and minimum standards related to study design; rationale of the intervention; criteria relating to needling stimulation either manual or electrostimulation; duration and frequency of treatment; and practitioner training. Conclusions: Items for inclusion in an instrument to assess quality acupuncture in clinical research were identified
    corecore