86 research outputs found

    Multifractals of Normalized First Passage Time in Sierpinski Gasket

    Full text link
    The multifractal behavior of the normalized first passage time is investigated on the two dimensional Sierpinski gasket with both absorbing and reflecting barriers. The normalized first passage time for Sinai model and the logistic model to arrive at the absorbing barrier after starting from an arbitrary site, especially obtained by the calculation via the Monte Carlo simulation, is discussed numerically. The generalized dimension and the spectrum are also estimated from the distribution of the normalized first passage time, and compared with the results on the finitely square lattice.Comment: 10 pages, Latex, with 3 figures and 1 table. to be published in J. Phys. Soc. Jpn. Vol.67(1998

    Bond-disordered Anderson model on a two dimensional square lattice - chiral symmetry and restoration of one-parameter scaling

    Full text link
    Bond-disordered Anderson model in two dimensions on a square lattice is studied numerically near the band center by calculating density of states (DoS), multifractal properties of eigenstates and the localization length. DoS divergence at the band center is studied and compared with Gade's result [Nucl. Phys. B 398, 499 (1993)] and the powerlaw. Although Gade's form describes accurately DoS of finite size systems near the band-center, it fails to describe the calculated part of DoS of the infinite system, and a new expression is proposed. Study of the level spacing distributions reveals that the state closest to the band center and the next one have different level spacing distribution than the pairs of states away from the band center. Multifractal properties of finite systems furthermore show that scaling of eigenstates changes discontinuously near the band center. This unusual behavior suggests the existence of a new divergent length scale, whose existence is explained as the finite size manifestation of the band center critical point of the infinite system, and the critical exponent of the correlation length is calculated by a finite size scaling. Furthermore, study of scaling of Lyapunov exponents of transfer matrices of long stripes indicates that for a long stripe of any width there is an energy region around band center within which the Lyapunov exponents cannot be described by one-parameter scaling. This region, however, vanishes in the limit of the infinite square lattice when one-parameter scaling is restored, and the scaling exponent calculated, in agreement with the result of the finite size scaling analysis.Comment: 23 pages, 11 figures. RevTe

    Differential response effects of data collection mode in a cancer screening study of unmarried women ages 40–75 years: A randomized trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Little is known about the impact of data collection method on self-reported cancer screening behaviours, particularly among hard-to-reach populations. The purpose of this study is to examine the effects of data collection mode on response to indicators of cancer screenings by unmarried middle-aged and older women.</p> <p>Methods</p> <p>Three survey methods were evaluated for collecting data about mammography and Papanicolaou (hereafter, Pap) testing among heterosexual and sexual minority (e.g., lesbian and bisexual) women. Women ages 40–75 were recruited from June 2003 – June 2005 in Rhode Island. They were randomly assigned to receive: Self-Administered Mailed Questionnaire [SAMQ; N = 202], Computer-Assisted Telephone Interview [CATI; N = 200], or Computer-Assisted Self-Interview [CASI; N = 197]. Logistic regression models were computed to assess survey mode differences for 13 self-reported items related to cancer screenings, adjusting for age, education, income, race, marital status, partner gender, and recruitment source.</p> <p>Results</p> <p>Compared to women assigned to CATI, women assigned to SAMQ were less likely to report two or more years between most recent mammograms (CATI = 23.2% vs. SAMQ = 17.7%; AOR = 0.5, 95% CI = 0.3 – 0.8) and women assigned to CASI were slightly less likely to report being overdue for mammography (CATI = 16.5% vs. CASI = 11.8%; AOR = 0.5, 95% CI = 0.3 – 1.0) and Pap testing (CATI = 14.9% vs. CASI = 10.0%; AOR = 0.5, 95% CI = 0.2 – 1.0). There were no other consistent mode effects.</p> <p>Conclusion</p> <p>Among participants in this sample, mode of data collection had little effect on the reporting of mammography and Pap testing behaviours. Other measures such as efficiency and cost-effectiveness of the mode should also be considered when determining the most appropriate form of data collection for use in monitoring indicators of cancer detection and control.</p

    Predictors of packed red cell transfusion after isolated primary coronary artery bypass grafting – The experience of a single cardiac center: A prospective observational study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Preoperative patients' characteristics can predict the need for perioperative blood component transfusion in cardiac surgical operations. The aim of this prospective observational study is to identify perioperative patient characteristics predicting the need for allogeneic packed red blood cell (PRBC) transfusion in isolated primary coronary artery bypass grafting (CABG) operations.</p> <p>Patients and Methods</p> <p>105 patients undergoing isolated, first-time CABG were reviewed for their preoperative variables and followed for intraoperative and postoperative data. Patients were 97 males and 8 females, with mean age 58.28 ± 10.97 years. Regression logistic analysis was used for identifying the strongest perioperative predictors of PRBC transfusion.</p> <p>Results</p> <p>PRBC transfusion was used in 71 patients (67.6%); 35 patients (33.3%) needed > 2 units and 14 (13.3%) of these needed > 4 units. Univariate analysis identified female gender, age > 65 years, body weight ≤ 70 Kg, BSA ≤ 1.75 m<sup>2</sup>, BMI ≤ 25, preoperative hemoglobin ≤ 13 gm/dL, preoperative hematocrit ≤ 40%, serum creatinine > 100 μmol/L, Euro SCORE (standard/logistic) > 2, use of CPB, radial artery use, higher number of distal anastomoses, and postoperative chest tube drainage > 1000 mL as significant predictors. The strongest predictors using multivariate analysis were CPB use, hematocrit, body weight, and serum creatinine.</p> <p>Conclusion</p> <p>The predictors of PRBC transfusion after primary isolated CABG are use of CPB, hematocrit ≤ 40%, weight ≤ 70 Kg, and serum creatinine > 100 μmol/L. This leads to better utilization of blood bank resources and cost-efficient targeted use of expensive blood conservation modalities.</p

    The ATLAS fast tracKer system

    Get PDF
    The ATLAS Fast TracKer (FTK) was designed to provide full tracking for the ATLAS high-level trigger by using pattern recognition based on Associative Memory (AM) chips and fitting in high-speed field programmable gate arrays. The tracks found by the FTK are based on inputs from all modules of the pixel and silicon microstrip trackers. The as-built FTK system and components are described, as is the online software used to control them while running in the ATLAS data acquisition system. Also described is the simulation of the FTK hardware and the optimization of the AM pattern banks. An optimization for long-lived particles with large impact parameter values is included. A test of the FTK system with the data playback facility that allowed the FTK to be commissioned during the shutdown between Run 2 and Run 3 of the LHC is reported. The resulting tracks from part of the FTK system covering a limited η-ϕ region of the detector are compared with the output from the FTK simulation. It is shown that FTK performance is in good agreement with the simulation. © The ATLAS collaboratio

    The ATLAS Fast TracKer system

    Get PDF
    The ATLAS Fast TracKer (FTK) was designed to provide full tracking for the ATLAS high-level trigger by using pattern recognition based on Associative Memory (AM) chips and fitting in high-speed field programmable gate arrays. The tracks found by the FTK are based on inputs from all modules of the pixel and silicon microstrip trackers. The as-built FTK system and components are described, as is the online software used to control them while running in the ATLAS data acquisition system. Also described is the simulation of the FTK hardware and the optimization of the AM pattern banks. An optimization for long-lived particles with large impact parameter values is included. A test of the FTK system with the data playback facility that allowed the FTK to be commissioned during the shutdown between Run 2 and Run 3 of the LHC is reported. The resulting tracks from part of the FTK system covering a limited η-ϕ region of the detector are compared with the output from the FTK simulation. It is shown that FTK performance is in good agreement with the simulation

    Decision Support and Patient Safety

    Full text link

    Finansial statement analyisis : analisis laporan keuangan

    No full text
    Buku: 2xxvi, 404 p. : il.; 26 c
    corecore