181 research outputs found

    Application of Headspace Solid-Phase Microextraction for Determination of Chloro-Organic Compounds in Sewage Samples

    Get PDF
    Solid phase microextraction (SPME) has been optimized and applied to the determination of the volatile halogenated compounds (VHCs) and semi-volatile halogenated compounds (SVHCs). Three types of SPME fiber coated with different stationary phases (PDMS–100 μm, CAR/PDMS-75 μm, PDMS/DVB–65 μm) were used to examine their extraction efficiencies for the compounds tested. Experimental parameters such as the selection of SPME coatings, extraction time, and addition of salts were studied. The carboxen-polydimethylsiloxane (CAR/PDMS) fiber appears to be the most suitable for the determination of VHCs. Analytical parameters such as linearity, limit of detection, and precision were also evaluated. Application of ECD detector for the determination of VHCs and SVHCs allows their determination on the low concentration level, ranging from 0.005 to 0.8 μg/L−1. The HS-SPME-GC/ECD procedure gave good analytical precision expressed as relative standard deviation (RSD) (ranged from 5.08% to 8.07%) for a concentration level of 5 μg/L−1 and good linearity (r2 > 0.98) in a wide calibration range. The applied HS-SPME-GC/ECD method was found to be a quick and effective technique for the determination of microtrace amounts of volatile and semi-volatile halogenated compounds in samples containing high amounts of various organic compounds

    The digital mirror Langmuir probe: Field programmable gate array implementation of real-time Langmuir probe biasing

    Get PDF
    High bandwidth, high spatial resolution measurements of electron temperature, density, and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements, either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimized for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customizable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g., real-time control outputs and more voltage states) and scalability through collaboration

    Radiative heat exhaust in Alcator C-Mod I-mode plasmas

    Get PDF
    In order to more completely demonstrate the I-mode regime as a compelling fusion reactor operating scenario, the first dedicated attempts at I-mode radiative heat exhaust and detachment were carried out on Alcator C-Mod. Results conclusively show that within the parameter space explored, an I/L back-transition is triggered prior to meaningful reductions in parallel heat flux, q||, target temperature, Te;tar, and target pressure, pe;tar, at the outer divertor. The exact mechanism for the I/L trigger remains uncertain, but a multi-diagnostic investigation suggests the pedestal regulation physics is impacted promptly by small amounts of N2 seeded into the private flux region. The time delay between when N2 contacts the plasma and the I/L transition is triggered varied from 30-120 ms, approximately 0.7-3 x tE, and the delay varied inversely with I-mode pedestal-top pressure, pe;95. Power and nitrogen influx scans indicate that the I/L transitions are not linked to excessive bulk-plasma impurity radiation. It is also shown that in the subsequent L-mode following nitrogen seeding, q|| and Te;tar can be reduced by factors of ~10. The I/L transition and L-mode exhaust results using N2 are compared to similar attempts using Ne where such q|| and Te;tar reductions in L-mode are limited to factors of 2-3. Implications for the I-mode regime are discussed, including needs for follow-up experiments on other facilities

    External excitation of a short-wavelength fluctuation in the Alcator C-Mod edge plasma and its relationship to the quasi-coherent mode

    Get PDF
    A novel “Shoelace” antenna has been used to inductively excite a short-wavelength edge fluctuation in a tokamak boundary layer for the first time. The principal design parameters, k[subscript ⊥] = 1.5 ± 0.1 cm[superscript −1] and 45 < f < 300 kHz, match the Quasi-Coherent Mode (QCM, k[subscript ⊥] ∼ 1.5 cm[superscript −1], f ∼ 50−150 kHz) in Alcator C-Mod, responsible for exhausting impurities in the steady-state, ELM-free Enhanced D[subscript α] H-mode. In H-mode, whether or not there is a QCM, the antenna drives coherent, field-aligned perturbations in density, [˜ over n][subscript e], and field, [˜ over B][subscript θ], which are guided by field lines, propagate in the electron diamagnetic drift direction, and exhibit a weakly damped (γ/ω[subscript 0] ∼ 5%−10%) resonance near the natural QCM frequency. This result is significant, offering the possibility that externally driven modes may be used to enhance particle transport. In L-mode, the antenna drives only a non-resonant [˜ over B][subscript θ] response. The facts that the driven mode has the same wave number and propagation direction as the QCM, and is resonant at the QCM frequency, suggest the antenna may couple to this mode, which we have shown elsewhere to be predominantly drift-mode-like [B. LaBombard et al., Phys. Plasmas 21, 056108 (2014)].United States. Dept. of Energy (Cooperative Agreement DE-FC02-99ER54512

    Results of screening in early and advanced thoracic malignancies in the EORTC pan-European SPECTAlung platform.

    Get PDF
    Access to a comprehensive molecular alteration screening is patchy in Europe and quality of the molecular analysis varies. SPECTAlung was created in 2015 as a pan-European screening platform for patients with thoracic malignancies. Here we report the results of almost 4 years of prospective molecular screening of patients with thoracic malignancies, in terms of quality of the program and molecular alterations identified. Patients with thoracic malignancies at any stage of disease were recruited in SPECTAlung, from June 2015 to May 2019, in 7 different countries. Molecular tumour boards were organised monthly to discuss patients' molecular and clinical profile and possible biomarker-driven treatments, including clinical trial options. FFPE material was collected and analysed for 576 patients with diagnosis of pleural, lung, or thymic malignancies. Ultimately, 539 patients were eligible (93.6%) and 528 patients were assessable (91.7%). The turn-around time for report generation and molecular tumour board was 214 days (median). Targetable molecular alterations were observed in almost 20% of cases, but treatment adaptation was low (3% of patients). SPECTAlung showed the feasibility of a pan-European screening platform. One fifth of the patients had a targetable molecular alteration. Some operational issues were discovered and adapted to improve efficiency

    Phase II Study of Radiotherapy and Temsirolimus versus Radiochemotherapy with Temozolomide in Patients with Newly Diagnosed Glioblastoma without MGMT Promoter Hypermethylation (EORTC 26082).

    Get PDF
    EORTC 26082 assessed the activity of temsirolimus in patients with newly diagnosed glioblastoma harboring an unmethylated O6 methylguanine-DNA-methyltransferase (MGMT) promoter. Patients (n = 257) fulfilling eligibility criteria underwent central MGMT testing. Patients with MGMT unmethylated glioblastoma (n = 111) were randomized 1:1 between standard chemo-radiotherapy with temozolomide or radiotherapy plus weekly temsirolimus (25 mg). Primary endpoint was overall survival at 12 months (OS12). A positive signal was considered &gt;38 patients alive at 12 months in the per protocol population. A noncomparative reference arm of 54 patients evaluated the assumptions on OS12 in a standard-treated cohort of patients. Prespecified post hoc analyses of markers reflecting target activation were performed. Both therapies were administered per protocol with a median of 13 cycles of maintenance temsirolimus. Median age was 55 and 58 years in the temsirolimus and standard arms, the WHO performance status 0 or 1 for most patients (95.5%). In the per protocol population, 38 of 54 patients treated with temsirolimus reached OS12. The actuarial 1-year survival was 72.2% [95% confidence interval (CI), 58.2-82.2] in the temozolomide arm and 69.6% (95% CI, 55.8-79.9) in the temsirolimus arm [hazard ratio (HR) 1.16; 95% CI, 0.77-1.76; P = 0.47]. In multivariable prognostic analyses of clinical and molecular factors, phosphorylation of mTORSer2448 in tumor tissue (HR 0.13; 95% CI, 0.04-0.47; P = 0.002), detected in 37.6%, was associated with benefit from temsirolimus. Temsirolimus was not superior to temozolomide in patients with an unmethylated MGMT promoter. Phosphorylation of mTORSer2448 in the pretreatment tumor tissue may define a subgroup benefitting from mTOR inhibition. Clin Cancer Res; 22(19); 4797-806. ©2016 AACR

    Phase II Study of Radiotherapy and Temsirolimus versus Radiochemotherapy with Temozolomide in Patients with Newly Diagnosed Glioblastoma without MGMT Promoter Hypermethylation (EORTC 26082).

    Get PDF
    EORTC 26082 assessed the activity of temsirolimus in patients with newly diagnosed glioblastoma harboring an unmethylated O6 methylguanine-DNA-methyltransferase (MGMT) promoter. Patients (n = 257) fulfilling eligibility criteria underwent central MGMT testing. Patients with MGMT unmethylated glioblastoma (n = 111) were randomized 1:1 between standard chemo-radiotherapy with temozolomide or radiotherapy plus weekly temsirolimus (25 mg). Primary endpoint was overall survival at 12 months (OS12). A positive signal was considered &gt;38 patients alive at 12 months in the per protocol population. A noncomparative reference arm of 54 patients evaluated the assumptions on OS12 in a standard-treated cohort of patients. Prespecified post hoc analyses of markers reflecting target activation were performed. Both therapies were administered per protocol with a median of 13 cycles of maintenance temsirolimus. Median age was 55 and 58 years in the temsirolimus and standard arms, the WHO performance status 0 or 1 for most patients (95.5%). In the per protocol population, 38 of 54 patients treated with temsirolimus reached OS12. The actuarial 1-year survival was 72.2% [95% confidence interval (CI), 58.2-82.2] in the temozolomide arm and 69.6% (95% CI, 55.8-79.9) in the temsirolimus arm [hazard ratio (HR) 1.16; 95% CI, 0.77-1.76; P = 0.47]. In multivariable prognostic analyses of clinical and molecular factors, phosphorylation of mTORSer2448 in tumor tissue (HR 0.13; 95% CI, 0.04-0.47; P = 0.002), detected in 37.6%, was associated with benefit from temsirolimus. Temsirolimus was not superior to temozolomide in patients with an unmethylated MGMT promoter. Phosphorylation of mTORSer2448 in the pretreatment tumor tissue may define a subgroup benefitting from mTOR inhibition. Clin Cancer Res; 22(19); 4797-806. ©2016 AACR

    Determination of chlorinated solvents in industrial water and wastewater by DAI–GC–ECD

    Get PDF
    A very simple and quick analytical method, based on direct aqueous injection, for determination of halogenated solvents in refinery water and wastewater, is described. There is a need to determine halogenated solvents in refinery water streams, because they may originate from several processes. There is also a need to develop methods enabling VOX to be determined in samples containing oil fractions. The method described enables simultaneous determination of 26 compounds with low detection limits (sub-μg L−1) and excellent precision, especially for highly halogenated solvents. The matrix effects of four types of sample were evaluated—the method seemed to be relatively insensitive to variations in matrix composition. Deuterated 1,2-dichloroethane was used as internal standard and surrogate compound in quantitative analysis; application of isotopically labelled compounds is rarely reported when non-mass spectrometric detectors are used for analysis. Analysis of real samples showed that the most frequently detected compounds were dichloromethane and 1,2-dichloroethane
    corecore