529 research outputs found

    Relationship among research collaboration, number of documents and number of citations. A case study in Spanish computer science production in 2000-2009.

    Get PDF
    This paper analyzes the relationship among research collaboration, number of documents and number of citations of computer science research activity. It analyzes the number of documents and citations and how they vary by number of authors. They are also analyzed (according to author set cardinality) under different circumstances, that is, when documents are written in different types of collaboration, when documents are published in different document types, when documents are published in different computer science subdisciplines, and, finally, when documents are published by journals with different impact factor quartiles. To investigate the above relationships, this paper analyzes the publications listed in the Web of Science and produced by active Spanish university professors between 2000 and 2009, working in the computer science field. Analyzing all documents, we show that the highest percentage of documents are published by three authors, whereas single-authored documents account for the lowest percentage. By number of citations, there is no positive association between the author cardinality and citation impact. Statistical tests show that documents written by two authors receive more citations per document and year than documents published by more authors. In contrast, results do not show statistically significant differences between documents published by two authors and one author. The research findings suggest that international collaboration results on average in publications with higher citation rates than national and institutional collaborations. We also find differences regarding citation rates between journals and conferences, across different computer science subdisciplines and journal quartiles as expected. Finally, our impression is that the collaborative level (number of authors per document) will increase in the coming years, and documents published by three or four authors will be the trend in computer science literature

    Drop-out rate from the liver transplant waiting list due to HCC progression in HCV-infected patients treated with direct acting antivirals.

    Get PDF
    BACKGROUND & AIM: concerns about an increased hepatocellular carcinoma (HCC) recurrence rate following directly acting antiviral (DAA) therapy in cirrhotic patients with a prior complete oncological response have been raised. Data regarding the impact of HCV-treatment with DAAs on waiting list drop-out rates in patients with active HCC and HCV-related cirrhosis awaiting liver transplantation (LT) are lacking. MATERIALS AND METHODS: HCV-HCC patients listed for LT between January 2015 and May 2016 at Padua Liver Transplant Centre were considered eligible for the study. After enrollment patients were divided into 2 groups, depending on whether they underwent DAAs treatment while awaiting LT or not. For each patient clinical, serological and virological data were collected. HCC characteristics were radiologically evaluated at baseline and during follow-up (FU). For transplanted patients, pathological assessment of the explants was performed and recurrence-rates were calculated. RESULTS: twenty-three patients treated with DAAs and 23 controls were enrolled. HCC characteristics at time of LT-listing were comparable between the 2 groups. Median FU was 10 and 7 months, respectively, during which 2/23 (8.7%) and 1/23 (4.3%) drop-out events due to HCC-progression were registered (p = 0.9). No significant differences in terms of radiological progression were highlighted (p = 0.16). Nine out of 23 cases (39%) and 14/23 (61%) controls underwent LT, and histopathological analysis showed no differences in terms of median number and total tumor volume of HCC nodules, tumor differentiation or microvascular invasion. During post-LT FU, 1/8 DAAs treated patient (12,5%) and 1/12 control (8,3%) experienced HCC recurrence (p = 0.6). CONCLUSIONS: Viral eradication does not seem to be associated with an increased risk of drop-out due to neoplastic progression in HCV-HCC patients awaiting LT

    Planck-LFI radiometers' spectral response

    Get PDF
    The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency. The characterization of the broadband frequency response of each radiometer is necessary to understand and correct for systematic effects, particularly those related to foreground residuals and polarization measurements. In this paper we present the measured band shape of all the LFI channels and discuss the methods adopted for their estimation. The spectral characterization of each radiometer was obtained by combining the measured spectral response of individual units through a dedicated RF model of the LFI receiver scheme. As a consistency check, we also attempted end-to-end spectral measurements of the integrated radiometer chain in a cryogenic chamber. However, due to systematic effects in the measurement setup, only qualitative results were obtained from these tests. The measured LFI bandpasses exhibit a moderate level of ripple, compatible with the instrument scientific requirements.Comment: 16 pages, 9 figures, this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jins

    Advanced modelling of the Planck-LFI radiometers

    Get PDF
    The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic microwave background (CMB) with unprecedented precision. In this paper we describe the development and validation of a software model of the LFI pseudo-correlation receivers which enables to reproduce and predict all the main system parameters of interest as measured at each of the 44 LFI detectors. These include system total gain, noise temperature, band-pass response, non-linear response. The LFI Advanced RF Model (LARFM) has been constructed by using commercial software tools and data of each radiometer component as measured at single unit level. The LARFM has been successfully used to reproduce the LFI behavior observed during the LFI ground-test campaign. The model is an essential element in the database of LFI data processing center and will be available for any detailed study of radiometer behaviour during the survey.Comment: 21 pages, 15 figures, this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jins

    Feminizing political parties: women’s party member organizations within European parliamentary parties

    Get PDF
    Party member women’s organizations were early features of party development. While some contemporary studies maintain these are important sites for the substantive representation of women, there is also a claim that they are in decline. Our primary purpose here is to establish the existence of party member women’s organizations – as one test of the first dimension of party feminization: the inclusion of women. We draw on new survey data of 17 European countries provided by Scarrow, Poguntke and Webb. We establish that almost half have a party member women’s organization. The new data also permits analysis of relationships between party member women’s organization and gender quotas for the top party leadership body (National Executive Committee (NEC)), women’s presence among the party leadership and candidate quota rules. Together we see these (i) as a means to establish whether women are marginalized within the party, thereby limiting descriptive representation and (ii) as surrogate measures for women’s substantive representation. We importantly find that the presence of a party member women’s organization does not come at the cost of women’s presence on the NEC. In the final section, we turn our attention to building a new comparative research agenda that more fully addresses substantive representation

    A timeband framework for modelling real-time systems

    Get PDF
    Complex real-time systems must integrate physical processes with digital control, human operation and organisational structures. New scientific foundations are required for specifying, designing and implementing these systems. One key challenge is to cope with the wide range of time scales and dynamics inherent in such systems. To exploit the unique properties of time, with the aim of producing more dependable computer-based systems, it is desirable to explicitly identify distinct time bands in which the system is situated. Such a framework enables the temporal properties and associated dynamic behaviour of existing systems to be described and the requirements for new or modified systems to be specified. A system model based on a finite set of distinct time bands is motivated and developed in this paper

    Thermal susceptibility of the Planck-LFI receivers

    Get PDF
    This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst . This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature fluctuations on the output signal. The origin of thermal instabilities in the instrument are discussed, and an analytical model of their propagation and impact on the receivers signal is described. The experimental test setup dedicated to evaluate these effects during the instrument ground calibration is reported together with data analysis methods. Finally, main results obtained are discussed and compared to the requirements.Comment: This is an author-created, un-copyedited version of an article accepted for publication in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T1201

    The Large-Scale Polarization Explorer (LSPE)

    Full text link
    The LSPE is a balloon-borne mission aimed at measuring the polarization of the Cosmic Microwave Background (CMB) at large angular scales, and in particular to constrain the curl component of CMB polarization (B-modes) produced by tensor perturbations generated during cosmic inflation, in the very early universe. Its primary target is to improve the limit on the ratio of tensor to scalar perturbations amplitudes down to r = 0.03, at 99.7% confidence. A second target is to produce wide maps of foreground polarization generated in our Galaxy by synchrotron emission and interstellar dust emission. These will be important to map Galactic magnetic fields and to study the properties of ionized gas and of diffuse interstellar dust in our Galaxy. The mission is optimized for large angular scales, with coarse angular resolution (around 1.5 degrees FWHM), and wide sky coverage (25% of the sky). The payload will fly in a circumpolar long duration balloon mission during the polar night. Using the Earth as a giant solar shield, the instrument will spin in azimuth, observing a large fraction of the northern sky. The payload will host two instruments. An array of coherent polarimeters using cryogenic HEMT amplifiers will survey the sky at 43 and 90 GHz. An array of bolometric polarimeters, using large throughput multi-mode bolometers and rotating Half Wave Plates (HWP), will survey the same sky region in three bands at 95, 145 and 245 GHz. The wide frequency coverage will allow optimal control of the polarized foregrounds, with comparable angular resolution at all frequencies.Comment: In press. Copyright 2012 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibite

    Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

    Get PDF
    The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.Comment: 15 pages, 18 figures. Accepted for publication in Astronomy and Astrophysic
    corecore