66 research outputs found

    On the chronological structure of the solutrean in Southern Iberia

    Get PDF
    The Solutrean techno-complex has gained particular significance over time for representing a clear demographic and techno-typological deviation from the developments occurred during the course of the Upper Paleolithic in Western Europe. Some of Solutrean's most relevant features are the diversity and techno-typological characteristics of the lithic armatures. These have been recurrently used as pivotal elements in numerous Solutrean-related debates, including the chronological organization of the techno-complex across Iberia and Southwestern France. In Southern Iberia, patterns of presence and/or absence of specific point types in stratified sequences tend to validate the classical ordering of the techno-complex into Lower, Middle and Upper phases, although some evidence, namely radiocarbon determinations, have not always been corroborative. Here we present the first comprehensive analysis of the currently available radiocarbon data for the Solutrean in Southern Iberia. We use a Bayesian statistical approach from 13 stratified sequences to compare the duration, and the start and end moments of each classic Solutrean phase across sites. We conclude that, based on the current data, the traditional organization of the Solutrean cannot be unquestionably confirmed for Southern Iberia, calling into doubt the status of the classically defined type-fossils as precise temporal markers.Fundacao para a Ciencia e Tecnologia [PTDC/HAH/64184/2006, PTDC/HIS-ARQ/117540/2010, SFRH/BD/65527/2009, SFRH/BPD/96277/2013]; National Geographic Society [8045-06]; Wenner-Gren Foundation for Anthropological Research [8290

    A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)

    Get PDF
    Meeting abstrac

    First Measurement of the Charge Asymmetry in Beauty-Quark Pair Production

    Get PDF
    The difference in the angular distributions between beauty quarks and antiquarks, referred to as the charge asymmetry, is measured for the first time in b (b) over bar pair production at a hadron collider. The data used correspond to an integrated luminosity of 1.0 fb(-1) collected at 7 TeV center-of-mass energy in proton-proton collisions with the LHCb detector. The measurement is performed in three regions of the invariant mass of the b (b) over bar system. The results obtained are A(C)(b (b) over bar) (40 10(5) GeV/c(2)) = 1.6 +/- 1.7 +/- 0.6%,where A(C)(b (b) over bar) is defined as the asymmetry in the difference in rapidity between jets formed from the beauty quark and antiquark, where in each case the first uncertainty is statistical and the second systematic. The beauty jets are required to satisfy 2 20 GeV, and have an opening angle in the transverse plane Delta phi > 2.6 rad. These measurements are consistent with the predictions of the standard model

    Guidelines for the use and interpretation of assays for monitoring autophagy (4th edition)1.

    Get PDF
    In 2008, we published the first set of guidelines for standardizing research in autophagy. Since then, this topic has received increasing attention, and many scientists have entered the field. Our knowledge base and relevant new technologies have also been expanding. Thus, it is important to formulate on a regular basis updated guidelines for monitoring autophagy in different organisms. Despite numerous reviews, there continues to be confusion regarding acceptable methods to evaluate autophagy, especially in multicellular eukaryotes. Here, we present a set of guidelines for investigators to select and interpret methods to examine autophagy and related processes, and for reviewers to provide realistic and reasonable critiques of reports that are focused on these processes. These guidelines are not meant to be a dogmatic set of rules, because the appropriateness of any assay largely depends on the question being asked and the system being used. Moreover, no individual assay is perfect for every situation, calling for the use of multiple techniques to properly monitor autophagy in each experimental setting. Finally, several core components of the autophagy machinery have been implicated in distinct autophagic processes (canonical and noncanonical autophagy), implying that genetic approaches to block autophagy should rely on targeting two or more autophagy-related genes that ideally participate in distinct steps of the pathway. Along similar lines, because multiple proteins involved in autophagy also regulate other cellular pathways including apoptosis, not all of them can be used as a specific marker for bona fide autophagic responses. Here, we critically discuss current methods of assessing autophagy and the information they can, or cannot, provide. Our ultimate goal is to encourage intellectual and technical innovation in the field

    Increased posterior translation but similar clinical outcomes using ultracongruent instead of posterior stabilized total knee arthroplasties in a prospective randomized trial

    No full text
    Data de publicació electrònica: 26-08-2021Purpose: The aim of this study was to compare the posterior tibial translation after ultracongruent (UC) and posterior-stabilized (PS) total knee arthroplasty (TKA) with two different UC with different heights in the anterior lip, and two different PS designs. This study also aimed to compare the range of motion (ROM) and outcomes scores after the use of these TKA models. It was hypothesised less posterior tibial translation after PS than after UC TKA, and less posterior tibial translation with a higher anterior lip in the UC insert than with a lower one. Methods: It was designed as a prospective randomized study of a group of 120 patients operated with a cemented TKA. To clarify the main purpose of the study, four groups were analysed using different polyethylene designs: Triathlon PS insert in group one, Triathlon UC insert in group two, U2 PS insert in group three and U2 UC insert in group four. One year after surgery, a forced posterior drawer with a Telos Stress applying 15 kg of force posteriorly on the proximal tibia at 90° of knee flexion was analysed in the lateral radiograph. Limb alignment, tibial posterior slope and posterior condylar offset were also studied. Results: 30 patients were included in each group. The average age was 73 years. There were 72.2% female and 27.8% male patients. There were no significant differences in any demographic or radiographic studied variables, preoperative range of motion (ROM) or preoperative Knee Society Scores (KSS) among the different groups. One year after surgery, the average postoperative ROM and the postoperative KSS Knee and KSS Function scores improved in respect of the preoperative values in all the groups. There were no significant differences in the postoperative outcome scores among the different groups (p = n.s.). Postoperative alignment of the limb, tibial posterior slope and posterior condylar offset were similar in the 4 study groups (p = n.s.). The postoperative posterior tibial translation was different between groups: the PS groups (groups 1 and 3) showed significant inferior values (p < 0.001) in respect of the UC groups (groups 2 and 4). There were no differences between both groups of PS models, but there was a significant increase in the posterior tibial translation of the Triathlon UC insert (11.2 mm SD 3.2) in respect of the U2 UC insert (6.1 mm SD 4.5) (p = 0.004). Conclusions: UC inserts restrict the posterior tibial translation after TKA less than PS inserts, but a design with a high anterior lip in the polyethylene UC insert can better control the posterior tibial translation than an insert with a small anterior lip

    Pressure algometry is a useful tool to quantify pain in the medial part of the knee: An intra- and inter-reliability study in healthy subjects.

    No full text
    PURPOSE: Pain quantification is essential for diagnostic and pain monitoring purposes in disorders around the knee. Pressure algometry is a method described to determine pressure pain threshold (PPT) by applying controlled pressure to a given body point. The purpose of this study was to determine the reliability of this method when it was applied to the medial part of the proximal tibia metaphysis and to evaluate the PPT levels between genders. METHODS: Fifty healthy (mean age; 46.9) volunteers were recruited, 25 men and 25 women. Pressure algometry was applied to a 1 cm(2)-probe area on the medial part of the knee by 2 raters. Intra- and interclass correlation (ICC) was obtained and differences between genders were evaluated. Bland-Altman plots were performed to evaluate the variability of the measures. RESULTS: The mean values of PPT obtained by rater 1 and 2 were 497.5 Kpa and 489 Kpa respectively. The intrarater reliability values (95% IC) for rater 1 and 2 were 0.97 (0.95-0.98) and 0.84 (0.73-0.90) respectively. With regard to interrater reliability, the ICC (95% IC) for the first measurement was 0.92 (0.87-0.95) and 0.86 (0.78-0.92) for the second one. Women showed significant lower values of PPT than men. The Bland-Altmand plots showed excellent agreement. CONCLUSIONS: Pressure algometry has excellent reliability when it is applied to the medial part of the proximal metaphysis of the tibia. Women have lower values of PTT than men. The high reliability of the PA in an individual volunteer makes it a more valuable tool for longitudinal assessment of a given patient than for comparison between them. LEVEL OF EVIDENCE:/nLevel III. Prospective study

    Use of antibiotic-loaded cement in total knee arthroplasty.

    No full text
    Bone cement has the capacity to release antibiotic molecules if any antibiotic is included in it, and these elution properties are improved as cement porosity is increased. In vitro studies have shown high local antibiotic concentration for many hours or few days after its use. Antibiotic loaded bone cement (ALBC) is helpful when treating an infection in total knee arthroplasty (TKA) revision surgery. The purpose of this paper was to review the evidence for the routine use of ALBC in TKA in the literature, its pros and cons. Many authors have recommended the use of ALBC also in primary TKA for infection prophylaxis, but the evidence based on data from National Registries, randomized clinical trials and meta-analysis suggest a protective effect of ALBC against infection when used in hips, but not (or only mild) in knees. A possible explanation to this finding is that the duration and quantity of locally elevated antibiotic levels after surgery are smaller in TKA, due to the smaller amount of cement used for fixation in TKA-only a layer in the bone surface. There are some concerns about the routine use of ALBC in primary TKA as prophylaxis against infection: Firstly, there is a risk of hypersensivity or toxicity even when the chance is highly improbable. Secondly, there is a reduction in the mechanical properties of the cement, but this can be probably neglected if the antibiotic is used in low doses, not more than 1 g per 40 g cement package. Another significant concern is the increased economic cost, which could be overlooked if there were enough savings in treating fewer prosthetic infections. Finally, there is also a risk of selection of antibiotic-resistant strains of bacteria and this could be the main concern. If used, the choice of the antibiotic mixed in ALBC should consider microbiological aspects (broad antimicrobial spectrum and low rate of resistant bacteria), physical and chemical aspects (thermal stability, high water solubility), pharmacological characteristics (low risk to allergic reactions or toxicity) and economic aspects (not too expensive). The most commonly used antibiotics in ALBC are gentamicin, tobramycin and vancomycin. In conclusion, there is a paucity of randomized clinical trials in the use of ALBC in primary TKAs and the actual evidence of the effect of ALBC in reducing the risk of infection is insufficient. This, in addition to concerns about patient safety, risks of increase in the antibiotic resistance of microorganisms and the increase in costs in the procedure, lead us to recommend a cautious use of ALBC, perhaps only in high-risk patients (immunocompromised, morbidly obese, diabetic and patients with previous history of fracture or infection around the knee) unless the benefits of ALBC use were fully proven. Meanwhile, the rigorous use of peri-operative prophylactic systemic antibiotics and adoption of efficient antiseptic procedures and improved surgical techniques must be considered the gold standard in infection prevention in TKA surgery
    corecore