2,631 research outputs found
The implausibility of ‘usual care’ in an open system: sedation and weaning practices in Paediatric Intensive Care Units (PICUs) in the United Kingdom (UK)
Background: The power of the randomised controlled trial depends upon its capacity to operate in a closed
system whereby the intervention is the only causal force acting upon the experimental group and absent in the
control group, permitting a valid assessment of intervention efficacy. Conversely, clinical arenas are open systems
where factors relating to context, resources, interpretation and actions of individuals will affect implementation and
effectiveness of interventions. Consequently, the comparator (usual care) can be difficult to define and variable in
multi-centre trials. Hence outcomes cannot be understood without considering usual care and factors that may
affect implementation and impact on the intervention.
Methods: Using a fieldwork approach, we describe PICU context, ‘usual’ practice in sedation and weaning from
mechanical ventilation, and factors affecting implementation prior to designing a trial involving a sedation and
ventilation weaning intervention. We collected data from 23 UK PICUs between June and November 2014 using
observation, individual and multi-disciplinary group interviews with staff.
Results: Pain and sedation practices were broadly similar in terms of drug usage and assessment tools. Sedation
protocols linking assessment to appropriate titration of sedatives and sedation holds were rarely used (9 % and 4 %
of PICUs respectively). Ventilator weaning was primarily a medical-led process with 39 % of PICUs engaging senior
nurses in the process: weaning protocols were rarely used (9 % of PICUs). Weaning methods were variably based
on clinician preference. No formal criteria or use of spontaneous breathing trials were used to test weaning
readiness. Seventeen PICUs (74 %) had prior engagement in multi-centre trials, but limited research nurse
availability. Barriers to previous trial implementation were intervention complexity, lack of belief in the evidence and
inadequate training. Facilitating factors were senior staff buy-in and dedicated research nurse provision.
Conclusions: We examined and identified contextual and organisational factors that may impact on the
implementation of our intervention. We found usual practice relating to sedation, analgesia and ventilator weaning
broadly similar, yet distinctively different from our proposed intervention, providing assurance in our ability to
evaluate intervention effects. The data will enable us to develop an implementation plan; considering these factors
we can more fully understand their impact on study outcomes
Endogenous cholinergic inputs and local circuit mechanisms govern the phasic mesolimbic dopamine response to nicotine
Nicotine exerts its reinforcing action by stimulating nicotinic acetylcholine receptors (nAChRs) and boosting dopamine (DA) output from the ventral tegmental area (VTA). Recent data have led to a debate about the principal pathway of nicotine action: direct stimulation of the DAergic cells through nAChR activation, or disinhibition mediated through desensitization of nAChRs on GABAergic interneurons. We use a computational model of the VTA circuitry and nAChR function to shed light on this issue. Our model illustrates that the α4β2-containing nAChRs either on DA or GABA cells can mediate the acute effects of nicotine. We account for in vitro as well as in vivo data, and predict the conditions necessary for either direct stimulation or disinhibition to be at the origin of DA activity increases. We propose key experiments to disentangle the contribution of both mechanisms. We show that the rate of endogenous acetylcholine input crucially determines the evoked DA response for both mechanisms. Together our results delineate the mechanisms by which the VTA mediates the acute rewarding properties of nicotine and suggest an acetylcholine dependence hypothesis for nicotine reinforcement.Peer reviewe
Complement-Mediated Virus Infectivity Neutralisation by HLA Antibodies Is Associated with Sterilising Immunity to SIV Challenge in the Macaque Model for HIV/AIDS.
Sterilising immunity is a desired outcome for vaccination against human immunodeficiency virus (HIV) and has been observed in the macaque model using inactivated simian immunodeficiency virus (SIV). This protection was attributed to antibodies specific for cell proteins including human leucocyte antigens (HLA) class I and II incorporated into virions during vaccine and challenge virus preparation. We show here, using HLA bead arrays, that vaccinated macaques protected from virus challenge had higher serum antibody reactivity compared with non-protected animals. Moreover, reactivity was shown to be directed against HLA framework determinants. Previous studies failed to correlate serum antibody mediated virus neutralisation with protection and were confounded by cytotoxic effects. Using a virus entry assay based on TZM-bl cells we now report that, in the presence of complement, serum antibody titres that neutralise virus infectivity were higher in protected animals. We propose that complement-augmented virus neutralisation is a key factor in inducing sterilising immunity and may be difficult to achieve with HIV/SIV Env-based vaccines. Understanding how to overcome the apparent block of inactivated SIV vaccines to elicit anti-envelope protein antibodies that effectively engage the complement system could enable novel anti-HIV antibody vaccines that induce potent, virolytic serological response to be developed
A Detailed History of Intron-rich Eukaryotic Ancestors Inferred from a Global Survey of 100 Complete Genomes
Protein-coding genes in eukaryotes are interrupted by introns, but intron densities widely differ between eukaryotic lineages. Vertebrates, some invertebrates and green plants have intron-rich genes, with 6–7 introns per kilobase of coding sequence, whereas most of the other eukaryotes have intron-poor genes. We reconstructed the history of intron gain and loss using a probabilistic Markov model (Markov Chain Monte Carlo, MCMC) on 245 orthologous genes from 99 genomes representing the three of the five supergroups of eukaryotes for which multiple genome sequences are available. Intron-rich ancestors are confidently reconstructed for each major group, with 53 to 74% of the human intron density inferred with 95% confidence for the Last Eukaryotic Common Ancestor (LECA). The results of the MCMC reconstruction are compared with the reconstructions obtained using Maximum Likelihood (ML) and Dollo parsimony methods. An excellent agreement between the MCMC and ML inferences is demonstrated whereas Dollo parsimony introduces a noticeable bias in the estimations, typically yielding lower ancestral intron densities than MCMC and ML. Evolution of eukaryotic genes was dominated by intron loss, with substantial gain only at the bases of several major branches including plants and animals. The highest intron density, 120 to 130% of the human value, is inferred for the last common ancestor of animals. The reconstruction shows that the entire line of descent from LECA to mammals was intron-rich, a state conducive to the evolution of alternative splicing
Classical and semi-classical energy conditions
The standard energy conditions of classical general relativity are (mostly)
linear in the stress-energy tensor, and have clear physical interpretations in
terms of geodesic focussing, but suffer the significant drawback that they are
often violated by semi-classical quantum effects. In contrast, it is possible
to develop non-standard energy conditions that are intrinsically non-linear in
the stress-energy tensor, and which exhibit much better well-controlled
behaviour when semi-classical quantum effects are introduced, at the cost of a
less direct applicability to geodesic focussing. In this article we will first
review the standard energy conditions and their various limitations. (Including
the connection to the Hawking--Ellis type I, II, III, and IV classification of
stress-energy tensors). We shall then turn to the averaged, nonlinear, and
semi-classical energy conditions, and see how much can be done once
semi-classical quantum effects are included.Comment: V1: 25 pages. Draft chapter, on which the related chapter of the book
"Wormholes, Warp Drives and Energy Conditions" (to be published by Springer),
will be based. V2: typos fixed. V3: small typo fixe
Longer First Introns Are a General Property of Eukaryotic Gene Structure
While many properties of eukaryotic gene structure are well characterized, differences in the form and function of introns that occur at different positions within a transcript are less well understood. In particular, the dynamics of intron length variation with respect to intron position has received relatively little attention. This study analyzes all available data on intron lengths in GenBank and finds a significant trend of increased length in first introns throughout a wide range of species. This trend was found to be even stronger when using high-confidence gene annotation data for three model organisms (Arabidopsis thaliana, Caenorhabditis elegans, and Drosophila melanogaster) which show that the first intron in the 5′ UTR is - on average - significantly longer than all downstream introns within a gene. A partial explanation for increased first intron length in A. thaliana is suggested by the increased frequency of certain motifs that are present in first introns. The phenomenon of longer first introns can potentially be used to improve gene prediction software and also to detect errors in existing gene annotations
Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis
Background
Ultrasound (US) has largely replaced contrast venography as the definitive diagnostic test for deep vein thrombosis (DVT). We aimed to derive a definitive estimate of the diagnostic accuracy of US for clinically suspected DVT and identify study-level factors that might predict accuracy.
Methods
We undertook a systematic review, meta-analysis and meta-regression of diagnostic cohort studies that compared US to contrast venography in patients with suspected DVT. We searched Medline, EMBASE, CINAHL, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Controlled Trials Register, Database of Reviews of Effectiveness, the ACP Journal Club, and citation lists (1966 to April 2004). Random effects meta-analysis was used to derive pooled estimates of sensitivity and specificity. Random effects meta-regression was used to identify study-level covariates that predicted diagnostic performance.
Results
We identified 100 cohorts comparing US to venography in patients with suspected DVT. Overall sensitivity for proximal DVT (95% confidence interval) was 94.2% (93.2 to 95.0), for distal DVT was 63.5% (59.8 to 67.0), and specificity was 93.8% (93.1 to 94.4). Duplex US had pooled sensitivity of 96.5% (95.1 to 97.6) for proximal DVT, 71.2% (64.6 to 77.2) for distal DVT and specificity of 94.0% (92.8 to 95.1). Triplex US had pooled sensitivity of 96.4% (94.4 to 97.1%) for proximal DVT, 75.2% (67.7 to 81.6) for distal DVT and specificity of 94.3% (92.5 to 95.8). Compression US alone had pooled sensitivity of 93.8 % (92.0 to 95.3%) for proximal DVT, 56.8% (49.0 to 66.4) for distal DVT and specificity of 97.8% (97.0 to 98.4). Sensitivity was higher in more recently published studies and in cohorts with higher prevalence of DVT and more proximal DVT, and was lower in cohorts that reported interpretation by a radiologist. Specificity was higher in cohorts that excluded patients with previous DVT. No studies were identified that compared repeat US to venography in all patients. Repeat US appears to have a positive yield of 1.3%, with 89% of these being confirmed by venography.
Conclusion
Combined colour-doppler US techniques have optimal sensitivity, while compression US has optimal specificity for DVT. However, all estimates are subject to substantial unexplained heterogeneity. The role of repeat scanning is very uncertain and based upon limited data
- …