59 research outputs found
Recommended from our members
Single Particle Fluorescence & Mass Spectrometry for the Detection of Biological Aerosols
Biological Aerosol Mass Spectrometry (BAMS) is an emerging technique for the detection of biological aerosols, which is being developed at Lawrence Livermore National Laboratory. The current system uses several orthogonal analytical methods to improve system selectivity, sensitivity and speed in order to maximize its utility as a biological aerosol detection system with extremely low probability of false alarm and high probability of detection. Our approach is to pre-select particles of interest by size and fluorescence prior to mass spectral analysis. The ability to distinguish biological aerosols from background and to discriminate bacterial spores, vegetative cells, viruses and toxins from one another will be shown. Data from particle standards of known chemical composition will be discussed. Analysis of ambient particles will also be presented
Recommended from our members
Centroid Position as a Function of Total Counts in a Windowed CMOS Image of a Point Source
We obtained 960,200 22-by-22-pixel windowed images of a pinhole spot using the Teledyne H2RG CMOS detector with un-cooled SIDECAR readout. We performed an analysis to determine the precision we might expect in the position error signals to a telescope's guider system. We find that, under non-optimized operating conditions, the error in the computed centroid is strongly dependent on the total counts in the point image only below a certain threshold, approximately 50,000 photo-electrons. The LSST guider camera specification currently requires a 0.04 arcsecond error at 10 Hertz. Given the performance measured here, this specification can be delivered with a single star at 14th to 18th magnitude, depending on the passband
Recommended from our members
Characterization of ambient aerosols at the San Francisco International Airport using BioAerosol Mass Spectrometry
The BioAerosol Mass Spectrometry (BAMS) system is a rapidly fieldable, fully autonomous instrument that can perform correlated measurements of multiple orthogonal properties of individual aerosol particles. The BAMS front end uses optical techniques to nondestructively measure a particle's aerodynamic diameter and fluorescence properties. Fluorescence can be excited at 266nm or 355nm and is detected in two broad wavelength bands. Individual particles with appropriate size and fluorescence properties can then be analyzed more thoroughly in a dual-polarity time-of-flight mass spectrometer. Over the course of two deployments to the San Francisco International Airport, more than 6.5 million individual aerosol particles were fully analyzed by the system. Analysis of the resulting data has provided a number of important insights relevant to rapid bioaerosol detection, which are described here
EXTREME TEMPERATURE AND EXTREME VIOLENCE: EVIDENCE FROM RUSSIA
We study the relationship between extreme temperatures and violent mortality, employing novel regional panel data from Russia. We find that extremely hot temperatures increase violent mortality, while extremely cold temperatures have no effect. The impact of hot temperature on violence is unequal across gender and age groups, rises noticeably during weekends, and leads to considerable social costs. Our findings also suggest that better job opportunities and lower vodka consumption may decrease this impact. The results underscore that economic policies need to target vulnerable population groups to mitigate the adverse impact of extreme temperatures. (JEL Q54, I14, K42). © 2020 The Authors. Economic Inquiry published by Wiley Periodicals LLC on behalf of Western Economic Association International.The authors thank Jason Lindo (co‐editor), three anonymous referees, Richard Frensch, Ali Kutan, Igor Makarov, Milena Nikolova, Mariola Pytlikova, and participants at the ASSA 2019 meeting in Atlanta, IOS/APB/EACES summer academy in Tutzing, and research seminars at IOS Regensburg, Curtin University, and the Laboratory for Economics of Climate Change at HSE Moscow for valuable comments. The authors acknowledge the support from Russian Science Foundation (RSCF) grant no. 19‐18‐00262
LSST: from Science Drivers to Reference Design and Anticipated Data Products
(Abridged) We describe here the most ambitious survey currently planned in
the optical, the Large Synoptic Survey Telescope (LSST). A vast array of
science will be enabled by a single wide-deep-fast sky survey, and LSST will
have unique survey capability in the faint time domain. The LSST design is
driven by four main science themes: probing dark energy and dark matter, taking
an inventory of the Solar System, exploring the transient optical sky, and
mapping the Milky Way. LSST will be a wide-field ground-based system sited at
Cerro Pach\'{o}n in northern Chile. The telescope will have an 8.4 m (6.5 m
effective) primary mirror, a 9.6 deg field of view, and a 3.2 Gigapixel
camera. The standard observing sequence will consist of pairs of 15-second
exposures in a given field, with two such visits in each pointing in a given
night. With these repeats, the LSST system is capable of imaging about 10,000
square degrees of sky in a single filter in three nights. The typical 5
point-source depth in a single visit in will be (AB). The
project is in the construction phase and will begin regular survey operations
by 2022. The survey area will be contained within 30,000 deg with
, and will be imaged multiple times in six bands, ,
covering the wavelength range 320--1050 nm. About 90\% of the observing time
will be devoted to a deep-wide-fast survey mode which will uniformly observe a
18,000 deg region about 800 times (summed over all six bands) during the
anticipated 10 years of operations, and yield a coadded map to . The
remaining 10\% of the observing time will be allocated to projects such as a
Very Deep and Fast time domain survey. The goal is to make LSST data products,
including a relational database of about 32 trillion observations of 40 billion
objects, available to the public and scientists around the world.Comment: 57 pages, 32 color figures, version with high-resolution figures
available from https://www.lsst.org/overvie
An integrated online radioassay data storage and analytics tool for nEXO
Large-scale low-background detectors are increasingly used in rare-event
searches as experimental collaborations push for enhanced sensitivity. However,
building such detectors, in practice, creates an abundance of radioassay data
especially during the conceptual phase of an experiment when hundreds of
materials are screened for radiopurity. A tool is needed to manage and make use
of the radioassay screening data to quantitatively assess detector design
options. We have developed a Materials Database Application for the nEXO
experiment to serve this purpose. This paper describes this database, explains
how it functions, and discusses how it streamlines the design of the
experiment
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Liquid xenon time projection chambers are promising detectors to search for
neutrinoless double beta decay (0), due to their response
uniformity, monolithic sensitive volume, scalability to large target masses,
and suitability for extremely low background operations. The nEXO collaboration
has designed a tonne-scale time projection chamber that aims to search for
0 of \ce{^{136}Xe} with projected half-life sensitivity of
~yr. To reach this sensitivity, the design goal for nEXO is
1\% energy resolution at the decay -value (~keV).
Reaching this resolution requires the efficient collection of both the
ionization and scintillation produced in the detector. The nEXO design employs
Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm
scintillation light of liquid xenon. This paper reports on the characterization
of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3
SiPMs specifically designed for nEXO, as well as new measurements on new test
samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters
(MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct
crosstalk, correlated avalanches and photon detection efficiency were measured
as a function of the applied over voltage and wavelength at liquid xenon
temperature (163~K). The results from this study are used to provide updated
estimates of the achievable energy resolution at the decay -value for the
nEXO design
Recommended from our members
A time projection chamber for high accuracy and precision fission cross-section measurements
The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber
MICROMEGAS TPC designed to make precision cross-section measurements of neutron-induced fission.
The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes
axially through the TPC inducing fission in the target. The 4π acceptance for fission fragments and
complete charged particle track reconstruction are powerful features of the fissionTPC which will be
used to measure fission cross-sections and examine the associated systematic errors. This paper provides
a detailed description of the design requirements, the design solutions, and the initial performance of
the fissionTPC.Keywords: Detectors, Fission, Time Projection Chamber, TP
- …