578 research outputs found

    Dose distribution in the thyroid gland following radiation therapy of breast cancer-a retrospective study

    Get PDF
    Purpose: To relate the development of post-treatment hypothyroidism with the dose distribution within the thyroid gland in breast cancer (BC) patients treated with loco-regional radiotherapy (RT). Methods and materials: In two groups of BC patients postoperatively irradiated by computer tomography (CT)- based RT, the individual dose distributions in the thyroid gland were compared with each other; Cases developed post-treatment hypothyroidism after multimodal treatment including 4-field RT technique. Matched patients in Controls remained free for hypothyroidism. Based on each patient’s dose volume histogram (DVH) the volume percentages of the thyroid absorbing respectively 20, 30, 40 and 50 Gy were then estimated (V20, V30, V40 and V50) together with the individual mean thyroid dose over the whole gland (MeanTotGy). The mean and median thyroid dose for the included patients was about 30 Gy, subsequently the total volume of the thyroid gland (VolTotGy) and the absolute volumes (cm3) receiving respectively < 30 Gy and ≥ 30 Gy were calculated (Vol < 30 and Vol ≥ 30) and analyzed. Results: No statistically significant inter-group differences were found between V20, V30, V40 and V50Gy or the median of MeanTotGy. The median VolTotGy in Controls was 2.3 times above VolTotGy in Cases (r = 0.003), with large inter-individual variations in both groups. The volume of the thyroid gland receiving < 30 Gy in Controls was almost 2.5 times greater than the comparable figure in Cases. Conclusions: We concluded that in patients with small thyroid glands after loco-radiotherapy of BC, the risk of post-treatment hypothyroidism depends on the volume of the thyroid gland.publishedVersio

    RESECT-SEG: Open access annotations of intra-operative brain tumor ultrasound images

    Full text link
    Purpose: Registration and segmentation of magnetic resonance (MR) and ultrasound (US) images play an essential role in surgical planning and resection of brain tumors. However, validating these techniques is challenging due to the scarcity of publicly accessible sources with high-quality ground truth information. To this end, we propose a unique annotation dataset of tumor tissues and resection cavities from the previously published RESECT dataset (Xiao et al. 2017) to encourage a more rigorous assessments of image processing techniques. Acquisition and validation methods: The RESECT database consists of MR and intraoperative US (iUS) images of 23 patients who underwent resection surgeries. The proposed dataset contains tumor tissues and resection cavity annotations of the iUS images. The quality of annotations were validated by two highly experienced neurosurgeons through several assessment criteria. Data format and availability: Annotations of tumor tissues and resection cavities are provided in 3D NIFTI formats. Both sets of annotations are accessible online in the \url{https://osf.io/6y4db}. Discussion and potential applications: The proposed database includes tumor tissue and resection cavity annotations from real-world clinical ultrasound brain images to evaluate segmentation and registration methods. These labels could also be used to train deep learning approaches. Eventually, this dataset should further improve the quality of image guidance in neurosurgery.Comment: Bahareh Behboodi and Francois-Xavier Carton share the first authorshi

    Dose distribution in the thyroid gland following radiation therapy of breast cancer-a retrospective study

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>To relate the development of post-treatment hypothyroidism with the dose distribution within the thyroid gland in breast cancer (BC) patients treated with loco-regional radiotherapy (RT).</p> <p>Methods and materials</p> <p>In two groups of BC patients postoperatively irradiated by computer tomography (CT)-based RT, the individual dose distributions in the thyroid gland were compared with each other; Cases developed post-treatment hypothyroidism after multimodal treatment including 4-field RT technique. Matched patients in Controls remained free for hypothyroidism. Based on each patient's dose volume histogram (DVH) the volume percentages of the thyroid absorbing respectively 20, 30, 40 and 50 Gy were then estimated (V20, V30, V40 and V50) together with the individual mean thyroid dose over the whole gland (MeanTotGy). The mean and median thyroid dose for the included patients was about 30 Gy, subsequently the total volume of the thyroid gland (VolTotGy) and the absolute volumes (cm<sup>3</sup>) receiving respectively < 30 Gy and ≥ 30 Gy were calculated (Vol < 30 and Vol ≥ 30) and analyzed.</p> <p>Results</p> <p>No statistically significant inter-group differences were found between V20, V30, V40 and V50Gy or the median of MeanTotGy. The median VolTotGy in Controls was 2.3 times above VolTotGy in Cases (ρ = 0.003), with large inter-individual variations in both groups. The volume of the thyroid gland receiving < 30 Gy in Controls was almost 2.5 times greater than the comparable figure in Cases.</p> <p>Conclusions</p> <p>We concluded that in patients with small thyroid glands after loco-radiotherapy of BC, the risk of post-treatment hypothyroidism depends on the volume of the thyroid gland.</p

    A comparative study of responses in planktonic food web structure and function in contrasting European coastal waters exposed to experimental nutrient addition

    Get PDF
    We quantify, compare, and generalize responses of experimental nutrient loadings (LN) on planktonic community structure and function in coastal waters. Data were derived from three mesocosm experiments undertaken in Baltic (BAL), Mediterranean (MED), and Norwegian (NOR) coastal waters. A planktonic model with seven functional compartments and 30-32 different carbon flows fit to all three experiments was used as a framework for flow-rate estimation and comparison. Flows were estimated on the basis of time series of measured biomass, some measured flows, and inverse modeling. Biomass and gross uptake rate of carbon of most groups increased linearly with increasing LN in the nutrient input range of 0-1 µmol N L-1 d-1 at all locations. The fate of the gross primary production (GPP) was similar in all systems. Autotrophic biomass varied by two orders of magnitude among locations, with the lowest biomass and response to nutrient addition in MED waters. The variation of GPP among sites was less than one order of magnitude. Mesozooplankton dominated by doliolids (Tunicata), but not those dominated by copepods, presumably exerted efficient control of the autotrophic biomass, thereby buffering responses of autotrophs to high nutrient input. Among the many factors that can modify the responses of autotrophs to nutrients, the time scale over which the enrichment is made and the precise mode of nutrient enrichment are important. We suggest a general concept that may contribute to a scientific basis for understanding and managing coastal eutrophicatio

    Measurement of the branching ratios of the Z0 into heavy quarks

    Full text link
    We measure the hadronic branching ratios of the Z0 boson into heavy quarks: Rb=Gamma(Z0->bb)/Gamma(Z0->hadrons) and Rc=Gamma(Z0->cc/Gamma(Z0->hadrons) using a multi-tag technique. The measurement was performed using about 400,000 hadronic Z0 events recorded in the SLD experiment at SLAC between 1996 and 1998. The small and stable SLC beam spot and the CCD-based vertex detector were used to reconstruct bottom and charm hadron decay vertices with high efficiency and purity, which enables us to measure most efficiencies from data. We obtain, Rb=0.21604 +- 0.00098(stat.) +- 0.00073(syst.) -+ 0.00012(Rc) and, Rc= 0.1744 +- 0.0031(stat.) +- 0.0020(syst.) -+ 0.0006(Rb)Comment: 37 pages, 8 figures, to be submitted to Phys. Rev. D version 2: changed title to ratios, used common D production fractions for Rb and Rc and corrected Zgamma interference. Identical to PRD submissio

    Testing in the incremental design and development of complex products

    Get PDF
    Testing is an important aspect of design and development which consumes significant time and resource in many companies. However, it has received less research attention than many other activities in product development, and especially, very few publications report empirical studies of engineering testing. Such studies are needed to establish the importance of testing and inform the development of pragmatic support methods. This paper combines insights from literature study with findings from three empirical studies of testing. The case studies concern incrementally developed complex products in the automotive domain. A description of testing practice as observed in these studies is provided, confirming that testing activities are used for multiple purposes depending on the context, and are intertwined with design from start to finish of the development process, not done after it as many models depict. Descriptive process models are developed to indicate some of the key insights, and opportunities for further research are suggested

    Direct Measurements of A_b and A_c using Vertex/Kaon Charge Tags at SLD

    Get PDF
    Exploiting the manipulation of the SLC electron-beam polarization, we present precise direct measurements of the parity violation parameters A_c and A_b in the Z boson - c quark and Z boson - b quark coupling. Quark/antiquark discrimination is accomplished via a unique algorithm that takes advantage of the precise SLD CCD vertex detector, employing the net charge of displaced vertices as well as the charge of kaons that emanate from those vertices. From the 1996-98 sample of 400,000 Z decays, produced with an average beam polarization of 73.4%, we find A_c = 0.673 +/- 0.029 (stat.) +/- 0.023 (syst.) and A_b = 0.919 +/- 0.018 (stat.) +/- 0.017 (syst.).Comment: 11 pages, 2 figures, 2 tables, to be submitted to Physical Review Letters; version 2 reflects changes suggested by the refere

    State-of-the-art in lean design engineering:a literature review on white collar lean

    Get PDF
    Lean is usually associated with the ‘operations’ of a manufacturing enterprise; however, there is a growing awareness that these principles may be transferred readily to other functions and sectors. The application to knowledge-based activities such as engineering design is of particular relevance to UK plc. Hence, the purpose of this study has been to establish the state-of-the-art, in terms of the adoption of Lean in new product development, by carrying out a systematic review of the literature. The authors' findings confirm the view that Lean can be applied beneficially away from the factory; that an understanding and definition of value is key to success; that a set-based (or Toyota methodology) approach to design is favoured together with the strong leadership of a chief engineer; and that the successful implementation requires organization-wide changes to systems, practices, and behaviour. On this basis it is felt that this review paper provides a useful platform for further research in this topic

    Search for time-dependent B0s - B0s-bar oscillations using a vertex charge dipole technique

    Get PDF
    We report a search for B0s - B0s-bar oscillations using a sample of 400,000 hadronic Z0 decays collected by the SLD experiment. The analysis takes advantage of the electron beam polarization as well as information from the hemisphere opposite that of the reconstructed B decay to tag the B production flavor. The excellent resolution provided by the pixel CCD vertex detector is exploited to cleanly reconstruct both B and cascade D decay vertices, and tag the B decay flavor from the charge difference between them. We exclude the following values of the B0s - B0s-bar oscillation frequency: Delta m_s < 4.9 ps-1 and 7.9 < Delta m_s < 10.3 ps-1 at the 95% confidence level.Comment: 18 pages, 3 figures, replaced by version accepted for publication in Phys.Rev.D; results differ slightly from first versio
    corecore