13 research outputs found

    May Measurement Month 2018: a pragmatic global screening campaign to raise awareness of blood pressure by the International Society of Hypertension

    Get PDF
    Aims Raised blood pressure (BP) is the biggest contributor to mortality and disease burden worldwide and fewer than half of those with hypertension are aware of it. May Measurement Month (MMM) is a global campaign set up in 2017, to raise awareness of high BP and as a pragmatic solution to a lack of formal screening worldwide. The 2018 campaign was expanded, aiming to include more participants and countries. Methods and results Eighty-nine countries participated in MMM 2018. Volunteers (≥18 years) were recruited through opportunistic sampling at a variety of screening sites. Each participant had three BP measurements and completed a questionnaire on demographic, lifestyle, and environmental factors. Hypertension was defined as a systolic BP ≥140 mmHg or diastolic BP ≥90 mmHg, or taking antihypertensive medication. In total, 74.9% of screenees provided three BP readings. Multiple imputation using chained equations was used to impute missing readings. 1 504 963 individuals (mean age 45.3 years; 52.4% female) were screened. After multiple imputation, 502 079 (33.4%) individuals had hypertension, of whom 59.5% were aware of their diagnosis and 55.3% were taking antihypertensive medication. Of those on medication, 60.0% were controlled and of all hypertensives, 33.2% were controlled. We detected 224 285 individuals with untreated hypertension and 111 214 individuals with inadequately treated (systolic BP ≥ 140 mmHg or diastolic BP ≥ 90 mmHg) hypertension. Conclusion May Measurement Month expanded significantly compared with 2017, including more participants in more countries. The campaign identified over 335 000 adults with untreated or inadequately treated hypertension. In the absence of systematic screening programmes, MMM was effective at raising awareness at least among these individuals at risk

    Pre-exposure rabies vaccination among US international travelers: findings from the global TravEpiNet consortium.

    No full text
    BACKGROUND: People who travel to areas with high rabies endemicity and have animal contact are at increased risk for rabies exposure. We examined characteristics of international travelers queried regarding rabies vaccination during pretravel consultations at Global TravEpiNet (GTEN) practices during 2009-2010. MATERIAL AND METHODS: We performed bivariate and multivariable analyses of data collected from 18 GTEN clinics. Travel destinations were classified by strength level of rabies vaccination recommendation. RESULTS: Of 13,235 travelers, 226 (2%) reported previous rabies vaccination, and 406 (3%) received rabies vaccine at the consultation. Common travel purposes for these 406 travelers were leisure (26%), research/education (17%), and nonmedical service work (14%). Excluding the 226 who were previously vaccinated, 8070 (62%) of 13,009 travelers intended to visit one or more countries with a strong recommendation for rabies vaccination; 1675 (21%) of these 8070 intended to travel for 1 month or more. Among these 1675 travelers, 145 (9%) were vaccinated, 498 (30%) declined vaccination, 832 (50%) had itineraries that clinicians determined did not indicate vaccination, and 200 (12%) remained unvaccinated for other reasons. In both bivariate and multivariate analyses, travelers with trip durations \u3e6 months versus 1-3 months (adjusted odds ratio [OR]=4.9 [95% confidence interval [CI] 2.1, 11.4]) and those traveling for research/education or to provide medical care (adjusted OR=5.1 [95% CI 1.9, 13.7] and 9.5 [95% CI 2.2, 40.8], respectively), compared with leisure travelers, were more likely to receive rabies vaccination. CONCLUSIONS: Few travelers at GTEN clinics received rabies vaccine, although many planned trips 1 month long or more to a strong-recommendation country. Clinicians often determined that vaccine was not indicated, and travelers often declined vaccine when it was offered. The decision to vaccinate should take into account the strength of the vaccine recommendation at the destination country, duration of stay, availability of postexposure prophylaxis, potential for exposure to animals, and likelihood of recurrent travel to high-risk destinations

    Informed Consent and the Elusive Dichotomy Between Standard and Experimental Therapy

    No full text

    Deep Underground Neutrino Experiment (DUNE) Near Detector Conceptual Design Report

    No full text
    International audienceThe Deep Underground Neutrino Experiment (DUNE) is an international, world-class experiment aimed at exploring fundamental questions about the universe that are at the forefront of astrophysics and particle physics research. DUNE will study questions pertaining to the preponderance of matter over antimatter in the early universe, the dynamics of supernovae, the subtleties of neutrino interaction physics, and a number of beyond the Standard Model topics accessible in a powerful neutrino beam. A critical component of the DUNE physics program involves the study of changes in a powerful beam of neutrinos, i.e., neutrino oscillations, as the neutrinos propagate a long distance. The experiment consists of a near detector, sited close to the source of the beam, and a far detector, sited along the beam at a large distance. This document, the DUNE Near Detector Conceptual Design Report (CDR), describes the design of the DUNE near detector and the science program that drives the design and technology choices. The goals and requirements underlying the design, along with projected performance are given. It serves as a starting point for a more detailed design that will be described in future documents

    Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC

    No full text
    DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6 ×\times  6 ×\times  6 m3^3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019–2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties.DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties
    corecore