800 research outputs found
Homogenization of magnitudes of the ISC Bulletin
We implemented an automatic procedure to download the hypocentral data of the online Bulletin of the International Seismological Centre (ISC) in order to produce in near real-time a homogeneous catalogue of the Global and EuroMediterranean instrumental seismicity to be used for forecasting experiments and other statistical analyses. For the interval covered by the reviewed ISC Bulletin, we adopt the ISC locations and convert the surface wave magnitude (Ms) and short-period body-wave magnitude (mb) as computed by the ISC to moment magnitude (Mw), using empirical relations. We merge the so obtained proxies with real Mw provided by global and EuroMediterranean moment tensor catalogues. For the most recent time interval (about 2 yr) for which the reviewed ISC Bulletin is not available, we do the same but using the preferred (prime) location provided by the ISC Bulletin and converting to Mw the Ms and mb provided by some authoritative agencies. For computing magnitude conversion equations, we use curvilinear relations defined in a previous work and the chi-square regression method that accounts for the uncertainties of both x and y variables
Interrelationship between miRNA and splicing factors in pancreatic ductal adenocarcinoma
Pancreatic ductal adenocarcinoma (PDAC) is one of the most lethal cancers because of diagnosis at late stage and inherent/acquired chemoresistance. Recent advances in genomic profiling and biology of this disease have not yet been translated to a relevant improvement in terms of disease management and patientâs survival. However, new possibilities for treatment may emerge from studies on key epigenetic factors. Deregulation of microRNA (miRNA) dependent gene expression and mRNA splicing are epigenetic processes that modulate the protein repertoire at the transcriptional level. These processes affect all aspects of PDAC pathogenesis and have great potential to unravel new therapeutic targets and/or biomarkers. Remarkably, several studies showed that they actually interact with each other in influencing PDAC progression. Some splicing factors directly interact with specific miRNAs and either facilitate or inhibit their expression, such as Rbfox2, which cleaves the well-known oncogenic miRNA miR-21. Conversely, miR-15a-5p and miR-25-3p significantly downregulate the splicing factor hnRNPA1 which acts also as a tumour suppressor gene and is involved in processing of miR-18a, which in turn, is a negative regulator of KRAS expression. Therefore, this review describes the interaction between splicing and miRNA, as well as bioinformatic tools to explore the effect of splicing modulation towards miRNA profiles, in order to exploit this interplay for the development of innovative treatments. Targeting aberrant splicing and deregulated miRNA, alone or in combination, may hopefully provide novel therapeutic approaches to fight the complex biology and the common treatment recalcitrance of PDAC
The HPS electromagnetic calorimeter
The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called âheavy photon.â Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015â2016. The calorimeter's main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. The detector is a homogeneous calorimeter, made of 442 lead-tungstate (PbWO4) scintillating crystals, each read out by an avalanche photodiode coupled to a custom trans-impedance amplifier
Training in critical care echocardiography
Echocardiography is useful for the diagnosis and management of hemodynamic failure in the intensive care unit so that competence in some elements of echocardiography is a core skill of the critical care specialist. An important issue is how to provide training to intensivists so that they are competent in the field. This article will review issues related to training in critical care echocardiography
Measurement of the atmospheric muon depth intensity relation with the NEMO Phase-2 tower
The results of the analysis of the data collected with the NEMO Phase-2
tower, deployed at 3500 m depth about 80 km off-shore Capo Passero (Italy), are
presented. Cherenkov photons detected with the photomultipliers tubes were used
to reconstruct the tracks of atmospheric muons. Their zenith-angle distribution
was measured and the results compared with Monte Carlo simulations. An
evaluation of the systematic effects due to uncertainties on environmental and
detector parameters is also included. The associated depth intensity relation
was evaluated and compared with previous measurements and theoretical
predictions. With the present analysis, the muon depth intensity relation has
been measured up to 13 km of water equivalent.Comment: submitted to Astroparticle Physic
Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab
MeV-GeV dark matter (DM) is theoretically well motivated but remarkably
unexplored. This Letter of Intent presents the MeV-GeV DM discovery potential
for a 1 m segmented plastic scintillator detector placed downstream of the
beam-dump at one of the high intensity JLab experimental Halls, receiving up to
10 electrons-on-target (EOT) in a one-year period. This experiment
(Beam-Dump eXperiment or BDX) is sensitive to DM-nucleon elastic scattering at
the level of a thousand counts per year, with very low threshold recoil
energies (1 MeV), and limited only by reducible cosmogenic backgrounds.
Sensitivity to DM-electron elastic scattering and/or inelastic DM would be
below 10 counts per year after requiring all electromagnetic showers in the
detector to exceed a few-hundred MeV, which dramatically reduces or altogether
eliminates all backgrounds. Detailed Monte Carlo simulations are in progress to
finalize the detector design and experimental set up. An existing 0.036 m
prototype based on the same technology will be used to validate simulations
with background rate estimates, driving the necessary RD towards an
optimized detector. The final detector design and experimental set up will be
presented in a full proposal to be submitted to the next JLab PAC. A fully
realized experiment would be sensitive to large regions of DM parameter space,
exceeding the discovery potential of existing and planned experiments by two
orders of magnitude in the MeV-GeV DM mass range.Comment: 28 pages, 17 figures, submitted to JLab PAC 4
The ANTARES Optical Beacon System
ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It
consists of a three dimensional array of photomultiplier tubes that can detect
the Cherenkov light induced by charged particles produced in the interactions
of neutrinos with the surrounding medium. High angular resolution can be
achieved, in particular when a muon is produced, provided that the Cherenkov
photons are detected with sufficient timing precision. Considerations of the
intrinsic time uncertainties stemming from the transit time spread in the
photomultiplier tubes and the mechanism of transmission of light in sea water
lead to the conclusion that a relative time accuracy of the order of 0.5 ns is
desirable. Accordingly, different time calibration systems have been developed
for the ANTARES telescope. In this article, a system based on Optical Beacons,
a set of external and well-controlled pulsed light sources located throughout
the detector, is described. This calibration system takes into account the
optical properties of sea water, which is used as the detection volume of the
ANTARES telescope. The design, tests, construction and first results of the two
types of beacons, LED and laser-based, are presented.Comment: 21 pages, 18 figures, submitted to Nucl. Instr. and Meth. Phys. Res.
- âŠ