38 research outputs found

    Projected WIMP sensitivity of the LUX-ZEPLIN dark matter experiment

    Get PDF
    LUX-ZEPLIN (LZ) is a next-generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with weakly interacting massive particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector. For a 1000 live day run using a 5.6-tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above 1.4 × 10-48cm2 for a 40 GeV/c2 mass WIMP. Additionally, a 5σ discovery potential is projected, reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of 2.3 × 10−43 cm2 (7.1 × 10−42 cm2) for a 40 GeV/c2 mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020

    Search for annual and diurnal rate modulations in the LUX experiment

    Get PDF
    Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth’s motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3±0.2  cpd/keVee/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26  keVee. Between 2 and 6  keVee, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2σ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2  cpd/keVee/tonne amplitude between 2 and 6  keVee.Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3±\pm0.2~cpd/keVee_{\text{ee}}/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keVee_{\text{ee}}. Between 2 and 6~keVee_{\text{ee}}, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2σ\sigma tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keVee_{\text{ee}}/tonne amplitude between 2 and 6~keVee_{\text{ee}}

    Measurement of the gamma ray background in the Davis Cavern at the Sanford Underground Research Facility

    Get PDF
    Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from γ-rays emitted by 40K and the 238U and 232Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4,850-foot level. In order to characterise the cavern background, in-situ γ-ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0--3300~keV) varied from 596~Hz to 1355~Hz for unshielded measurements, corresponding to a total flux in the cavern of 1.9±0.4~γ cm−2s−1. The resulting activity in the walls of the cavern can be characterised as 220±60~Bq/kg of 40K, 29±15~Bq/kg of 238U, and 13±3~Bq/kg of 232Th

    Highly-parallelized simulation of a pixelated LArTPC on a GPU

    Get PDF
    The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on 10^3 pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype

    Author's reply

    No full text

    Author's reply

    No full text

    Literature review on identification of ship and ship wake by using Synthetic Aperture Radar

    Get PDF
    Literatures on identification of ship and ship wake by using synthetic aperture radar (SAR) are reviewed. Single frequency single polarimetric SAR (ex. RADARSAT SAR) has shown limited capabilities for identifying ships and ship wakes while multi-frequency multi-polarimetric SAR (ex. Pi-SAR) has indicated some potentials to distinguish between ships and ship wakes especially by using polarimetric signatures. Further investigations are needed to characterize ship structure and ship wake with satellite-borne multi-polarimetric data (ex. ENVISAT/ASAR, ALOS/PALSAR)

    Heidelberg retina tomograph (hrt3) in population-based epidemiology: normative values and criteria for glaucomatous optic neuropathy.

    No full text
    Purpose: To establish normative values for Heidelberg Retina Tomograph (HRT3) variables and to develop HRT3-based criteria for glaucomatous optic neuropathy for epidemiological research in a white population. Methods: Consecutive participants in the Rotterdam Study were examined with HRT and simultaneous stereoscopic fundus photography (ImageNet) in addition to other ophthalmic examinations including intraocular pressure (IOP) measurements and perimetry. Normative values for all HRT3 variables were determined in participants who met all the following criteria: no glaucomatous visual field loss (GVFL), an IOP of 21mmHg or less, no IOP lowering treatment, and a negative family history of glaucoma. Sensitivity was determined in participants with glaucomatous visual field loss at a fixed high specificity of 97.5% - a value commonly used in population-based epidemiology. Results: A total of 2516 participants were included in this study of whom 66 had glaucomatous visual field loss in at least one eye and 1680 fulfilled the criteria for contributing to the normative values. The HRT3 linear cup-disc ratio (LCDR) variable, adjusted for disc area, showed the highest sensitivity, 35%, at the required specificity of 97.5%. The 97.5th percentile of the LCDR was 0.67 for small discs (up to 1.5mm Conclusions: At the high specificity of 97.5% as is commonly used in population-based epidemiology, the sensitivity of the HRT3 is low - albeit not lower than that of the vertical cup-disc ratio as assessed with simultaneous stereoscopic fundus photography and analyzed with the ImageNet software. The LCDR variable, stratified for disc area, seems to be the most suitable variable to develop criteria for glaucomatous optic neuropathy for epidemiological purposes

    Author response: incident open-angle glaucoma and ocular perfusion pressure.

    No full text
    corecore