1,023 research outputs found
Primates in peril: The world's 25 most endangered primates, 2006-2008
From first paragraph: Here we report on the fourth iteration of the biennial listing of a consensus of 25 primate species considered to be amongst the most endangered worldwide and the most in need of urgent conservation measures. The first was drawn up in 2000 by the IUCN/SSC Primate Specialist Group, together with Conservation International (Mittermeier et al. 2000). The list was subsequently reviewed and updated in 2002 during an open meeting held during the 19th Congress of the International Primatological Society (IPS) in Beijing, China (Mittermeier et al. 2002). That occasion provided for debate among primatologists working in the field who had first-hand knowledge of the causes of threats to primates, both in general and in particular with the species or communities they study
An Intercomparison of Ground-based Solar FTIR Measurements of Atmospheric Gases at Eureka, Canada
We report the results of an intercomparison of vertical column amounts of hydrogen chloride (HCl), hydrogen fluoride (HF), nitrous oxide (N2O), nitric acid (HNO3), methane (CH4), ozone (O3), carbon dioxide (CO2) and nitrogen (N2) derived from the spectra recorded by two ground-based Fourier transform infrared (FTIR) spectrometers operated side-by-side using the sun as a source. The procedure used to record spectra and derive vertical column amounts follows the format of previous instrument intercomparisons organised by the Network for Detection of Atmospheric Composition Change (NDACC), formerly known as the Network for Detection of Stratospheric Change (NDSC). For most gases the differences were typically around 3% and in about half of the results the error bars given by the standard deviation of the measurements from each instrument did not overlap. The worst level of agreement was for HF where differences of over 5% were typical. The level of agreement achieved during this intercomparison is a little worse than that achieved in previous intercomparisons between ground-based FTIR spectrometers
Four in One: Cryptic Diversity in Geoffroy’s Side-Necked Turtle \u3cem\u3ePhrynops geoffroanus\u3c/em\u3e (Schweigger 1812) (Testudines: Pleurodira: Chelidae) in Brazil
Turtles are one of the most threatened groups of vertebrates, with about 60% of species classified at some level of extinction risk. Compounding this extinction crisis are cryptic species and species complexes that are evaluated under a single species epithet but harbor multiple species, each of which needs to be evaluated independently. The Phrynops geoffroanus species group is a classic example. Described first in 1812, it is currently thought to harbor multiple species. To test this hypothesis, we collected mitochondrial and nuclear genomic data, morphometric data, and distribution and associated biome information. We applied statistically rigorous species delimitation analyses, taxonomic hypotheses tests, and fully coalescent phylogenetic reconstruction methods, concluding that the Phrynops geoffroanus species complex comprises four geographically structured species/lineages that diverged during the Pleistocene and are currently geographically structured along the main South American river basins and biomes. These species/lineages show subtle and largely non-significant differences in shape but are characterized by differences in coloration and patterns of marks on the head and plastron. Our results contribute to the understanding of species diversity and diversification of biodiversity in South America and provide an important basis for the conservation of freshwater turtles
Comparisons between SCIAMACHY atmospheric CO<sub>2</sub> retrieved using (FSI) WFM-DOAS to ground based FTIR data and the TM3 chemistry transport model
International audienceAtmospheric CO2 concentrations, retrieved from spectral measurements made in the near infrared (NIR) by the SCIAMACHY instrument, using Full Spectral Initiation Weighting Function Modified Differential Optical Absorption Spectroscopy (FSI WFM-DOAS), are compared to ground based Fourier Transform Infrared (FTIR) data and to the output from a global chemistry-transport model. Analysis of the FSI WFM-DOAS retrievals with respect to the ground based FTIR instrument, located at Egbert, Canada, show good agreement with an average negative bias of approximately ?4.0% with a standard deviation of ~3.0%. This bias which exhibits an apparent seasonal trend, is of unknown origin, though slight differences between the averaging kernels of the instruments and the limited temporal coverage of the FTIR data may be the cause. The relative scatter of the retrieved vertical column densities is comparable to the spread of the FTIR measurements themselves. Normalizing the CO2 columns using the surface pressure does not affect the magnitude of this bias although it slightly increases the scatter of the FSI data. Comparisons of the FSI retrievals to the TM3 global chemistry-transport model, performed over four selected Northern Hemisphere scenes show good agreement. The correlation, between the time series of the SCIAMACHY and model monthly scene averages, are ~0.7 or greater, demonstrating the ability of SCIAMACHY to detect seasonal changes in the CO2 distribution. The amplitude of the seasonal cycle, peak to peak, observed by SCIAMACHY however, is overestimated by a factor of 2?3, which cannot be explained. The yearly means detected by SCIAMACHY are within 2% of those of the model with the mean difference between the CO2 distributions also approximately 2.0%. Additionally, analysis of the retrieved CO2 distributions reveals structure not evident in the model fields which correlates well with land classification type. From these comparisons, the overall precision and bias of the CO2 columns retrieved by the FSI algorithm are estimated to be close to 1.0% and <4.0% respectively
Autonomy of Nations and Indigenous Peoples and the Environmental Release of Genetically Engineered Animals with Gene Drives
This article contends that the environmental release of genetically engineered (GE) animals with heritable traits that are patented will present a challenge to the efforts of nations and indigenous peoples to engage in self‐determination. The environmental release of such animals has been proposed on the grounds that they could function as public health tools or as solutions to the problem of agricultural insect pests. This article brings into focus two political‐economic‐legal problems that would arise with the environmental release of such organisms. To address those challenges, it is proposed that nations considering the environmental release of GE animals must take into account the underlying circumstances and policy failures that motivate arguments for the use of the modified animals. Moreover, countries must recognize that the UN International Covenant on Civil and Political Rights and the UN International Covenant on Economic, Social and Cultural Rights place on them an obligation to ensure that GE animals with patented heritable traits are not released without the substantive consent of the nations or indigenous peoples that could be affected
Recommended from our members
Lunar and solar FTIR nitric acid measurements at Eureka in winter 2001/2002: comparisons with observations at Thule and Kiruna and with CMAM and SLIMCAT model calculations
For the first time, vertical column measurements of (HNO3) above the Arctic Stratospheric Ozone Observatory (AStrO) at Eureka (80N, 86W), Canada, have been made during polar night using lunar spectra recorded with a Fourier Transform Infrared (FTIR) spectrometer, from October 2001 to March 2002. AStrO is part of the primary Arctic station of the Network for the Detection of Stratospheric Change (NDSC). These measurements were compared with FTIR measurements at two other NDSC Arctic sites: Thule, Greenland (76.5N, 68.8W) and Kiruna, Sweden (67.8N, 20.4E). The measurements were also compared with two atmospheric models: the Canadian
Middle Atmosphere Model (CMAM) and SLIMCAT. This is the first time that CMAM HNO3 columns have been compared with observations in the Arctic. Eureka lunar measurements are in good agreement with solar ones made with the same instrument. Eureka and Thule HNO3 columns are consistent within measurement error. Differences among HNO3 columns measured at Kiruna and those measured at Eureka and Thule can be explained on the basis of the available sunlight hours and the polar vortex location. The comparison of CMAM HNO3 columns with Eureka and Kiruna data shows good agreement, considering CMAM small inter-annual variability. The warm 2001/02 winter with almost no Polar Stratospheric Clouds (PSCs) makes the comparison of the warm climate version of CMAM with these observations a good test for CMAM under no PSC conditions. SLIMCAT captures the magnitude of HNO3 columns at Eureka, and the day-to-day variability, but generally reports higher HNO3 columns than the CMAM climatological mean columns
Simultaneous atmospheric measurements using two Fourier transform infrared spectrometers at the Polar Environment Atmospheric Research Laboratory during spring 2006, and comparisons with the Atmospheric Chemistry Experiment-Fourier Transform Spectrometer
International audienceThe 2006 Canadian Arctic ACE (Atmospheric Chemistry Experiment) Validation Campaign collected measurements at the Polar Environment Atmospheric Research Laboratory (PEARL, 80.05° N, 86.42° W, 610 m above sea level) at Eureka, Canada from 17 February to 31 March 2006. Two of the ten instruments involved in the campaign, both Fourier transform spectrometers (FTSs), were operated simultaneously, recording atmospheric solar absorption spectra. The first instrument was an ABB Bomem DA8 high-resolution infrared FTS. The second instrument was the Portable Atmospheric Research Interferometric Spectrometer for the Infrared (PARIS-IR), the ground-based version of the satellite-borne FTS on the ACE satellite (ACE-FTS). From the measurements collected by these two ground-based instruments, total column densities of seven stratospheric trace gases (O3, HNO3, NO2, HCl, HF, NO, and ClONO2 were retrieved using the optimal estimation method and these results were compared. Since the two instruments sampled the same portions of atmosphere by synchronizing observations during the campaign, the biases in retrieved columns from the two spectrometers represent the instrumental differences. These differences were consistent with those seen in previous FTS intercomparison studies. Partial column results from the ground-based spectrometers were also compared with partial columns derived from ACE-FTS version 2.2 (including updates for O3, HDO and N2O5 profiles and the differences found were consistent with the other validation comparison studies for the ACE-FTS version 2.2 data products. Column densities of O3, HCl, ClONO2, and HNO3 from the three FTSs were normalized with respect to HF and used to probe the time evolution of the chemical constituents in the atmosphere over Eureka during spring 2006
The efficiency of indicator groups for the conservation of amphibians in the Brazilian Atlantic Forest
The adequate selection of indicator groups of biodiversity is an important aspect of the systematic conservation planning. However, these assessments differ in the spatial scale, in the methods used and in the groups considered to accomplish this task, which generally produces contradictory results. The quantification of the spatial congruence between species richness and complementarity among different taxonomic groups is a fundamental step to identify potential indicator groups. Using a constructive approach, the main purposes of this study were to evaluate the performance and efficiency of eight potential indicator groups representing amphibian diversity in the Brazilian Atlantic Forest. Data on the geographic range of amphibian species that occur in the Brazilian Atlantic Forest was overlapped to the full geographic extent of the biome, which was divided into a regular equal-area grid. Optimization routines based on the concept of complementarily were applied to verify the performance of each indicator group selected in relation to the representativeness of the amphibians in the Brazilian Atlantic Forest as a whole, which were solved by the algorithm"simulated annealing", through the use of the software MARXAN. Some indicator groups were substantially more effective than others in regards to the representation of the taxonomic groups assessed, which was confirmed by the high significance of data (F = 312.76; p < 0.01). Leiuperidae was considered as the best indicator group among the families analyzed, as it showed a good performance, representing 71% of amphibian species in the Brazilian Atlantic Forest (i.e. 290 species), which may be associated with the diffuse geographic distribution of its species. This study promotes understanding of how the diversity standards of amphibians can be informative for systematic conservation planning on a regional scale
VALIDATION OF ENVISAT-1 LEVEL-2 PRODUCTS RELATED TO LOWER ATMOSPHERE O3 AND NOy CHEMISTRY BY A FTIR QUASI-GLOBAL NETWORK
A coordinated action involving eleven stations of the ground-based Network for Detection of Stratospheric Change (NDSC) equipped with Fourier transform infrared (FTIR) instruments was conducted to contribute to the validation of the three atmospheric chemistry instruments onboard ENVISAT, that are MIPAS, SCIAMACHY and GOMOS.
The target products for validation are total columns of O3, CH4, CO and some important NOy species (NO2, HNO3, NO) and the source gas N2O. Together the eleven stations cover the latitudes between 79 °N and 78°S, including polar, mid -latitude and subtropical and tropical locations. The goal is to contribute to the assessment of the data quality of the aforementioned ENVISAT instruments, from a quasi-global perspective.
The period of intensive ground-based data collection for the benefit of the ENVISAT Validation Commissioning Phase that is dealt with in the present paper is July 15 to December 1, 2002. The FTIR network involved collected a data set corresponding to an equivalent of approximately 400 days of measurements; about three quarter of the data have already been submitted to the ENVISAT Calval database and are included in the present work.
Unfortunately, the distribution of ENVISAT data has been slow and limited. Only a limited number of coincidences has been found for making data inter-comparisons. Therefore, the conclusions drawn in this paper are very preliminary and cover only a limited set of data products from SCIAMACHY only.
Our findings up to now concerning the above mentioned target products are the following: (1) SCIAMACHY near infrared operational products (CO, CH4, N2O) have no scientific meaning yet, (2), the operational SCIAMACHY total vertical O3 column product derived in the ultraviolet window has undergone some improvements with changing versions of the processor(s) but it still underestimates the column by about 5 – 10 %, (3), the operational SCIAMACHY total vertical O3 column product derived in the visible window is unrealistically large, and (3), the operational NO2 total column product from SCIAMACHY seems to largely overestimate the real column, but very few coincidences and large dispersions of the data do inhibit any further conclusion at present.
In a next phase, the same ground-based correlative data set will be exploited to further validate the ENVISAT data as soon as more and reprocessed data will be distributed
- …