137 research outputs found

    Polymer electrolytes based on modified natural rubber

    Get PDF
    Modified natural rubber polymer hosts having low transition glass temperatures have been investigated for use in polymer electrolytes. Two types of modified natural rubber, namely 25% epoxidised natural rubber (ENR-25) and 50% epoxidised natural rubber (ENR-50) were employed in conjunction with poly(ethylene oxide), PEO. Results are reported for ionic conductivity and thermal properties for both unplasticized and plasticized polymer electrolyte systems with lithium triflate. The samples were in the form of free standing films with the thickness 0.2–0.5 mm and mixtures of ethylene carbonate (EC) and propylene carbonate (PC) were used as plasticizers. Unplasticized modified natural rubber-based systems exhibit ionic conductivities in the range 10−6 to 10−5 S cm−1 at ambient temperatures. Incorporating 100% of EC/PC by weight fraction of polymer (ENR/PEO) to the systems yielded mechanically stable films and ionic conductivities in the range of 10−4 S cm−1 at ambient temperature

    Wavelength calibration of the JWST-MIRI medium resolution spectrometer

    Full text link
    We present the wavelength and spectral resolution characterisation of the Integral Field Unit (IFU) Medium Resolution Spectrometer for the Mid-InfraRed Instrument (MIRI), to fly onboard the James Webb Space Telescope in 2014. We use data collected using the Verification Model of the instrument and develop an empirical method to calibrate properties such as wavelength range and resolving power in a portion of the spectrometer's full spectral range (5-28 microns). We test our results against optical models to verify the system requirements and combine them with a study of the fringing pattern in the instrument's detector to provide a more accurate calibration. We show that MIRI's IFU spectrometer will be able to produce spectra with a resolving power above R=2800 in the wavelength range 6.46-7.70 microns, and that the unresolved spectral lines are well fitted by a Gaussian profile.Comment: 12 pages, submitted to SPIE Proceedings vol. 7731, Space Telescopes and Instrumentation 2010: Optical, Infrared, and Millimeter Wav

    The Mid-Infrared Instrument for the James Webb Space Telescope, V: Predicted Performance of the MIRI Coronagraphs

    Full text link
    The imaging channel on the Mid-Infrared Instrument (MIRI) is equipped with four coronagraphs that provide high contrast imaging capabilities for studying faint point sources and extended emission that would otherwise be overwhelmed by a bright point-source in its vicinity. Such bright sources might include stars that are orbited by exoplanets and circumstellar material, mass-loss envelopes around post-main-sequence stars, the near-nuclear environments in active galaxies, and the host galaxies of distant quasars. This paper describes the coronagraphic observing modes of MIRI, as well as performance estimates based on measurements of the MIRI flight model during cryo-vacuum testing. A brief outline of coronagraphic operations is also provided. Finally, simulated MIRI coronagraphic observations of a few astronomical targets are presented for illustration

    The Origin of the Silicate Emission Features in the Seyfert 2 Galaxy, NGC 2110

    Full text link
    The unified model of active galactic nuclei (AGN) predicts silicate emission features at 10 and 18 microns in type 1 AGN, and such features have now been observed in objects ranging from distant QSOs to nearby LINERs. More surprising, however, is the detection of silicate emission in a few type 2 AGN. By combining Gemini and Spitzer mid-infrared imaging and spectroscopy of NGC 2110, the closest known Seyfert 2 galaxy with silicate emission features, we can constrain the location of the silicate emitting region to within 32 pc of the nucleus. This is the strongest constraint yet on the size of the silicate emitting region in a Seyfert galaxy of any type. While this result is consistent with a narrow line region origin for the emission, comparison with clumpy torus models demonstrates that emission from an edge-on torus can also explain the silicate emission features and 2-20 micron spectral energy distribution of this object. In many of the best-fitting models the torus has only a small number of clouds along the line of sight, and does not extend far above the equatorial plane. Extended silicate-emitting regions may well be present in AGN, but this work establishes that emission from the torus itself is also a viable option for the origin of silicate emission features in active galaxies of both type 1 and type 2.Comment: ApJL, accepte

    E-ELT/METIS

    Full text link
    The Mid-infrared E-ELT Imager and Spectrograph (METIS) will be one of the first three scientific instruments on the European Extremely Large Telescope (E-ELT). It will be the only instrument to cover the thermal/mid-infrared wavelength range from 3-19 μm. METIS offers a number of scientifically important observing modes, including diffraction-limited imaging, low resolution slit spectroscopy, coronagraphy, and high resolution (R ˜ 100,000) integral field spectroscopy at very high sensitivity. This paper gives a brief summary of METIS and focuses on its unique discovery space in the area of protoplanetary disks, where METIS is quite complementary to ALMA and JWST

    The Mid-Infrared Instrument for the James Webb Space Telescope, III: MIRIM, The MIRI Imager

    Get PDF
    In this article, we describe the MIRI Imager module (MIRIM), which provides broad-band imaging in the 5 - 27 microns wavelength range for the James Webb Space Telescope. The imager has a 0"11 pixel scale and a total unobstructed view of 74"x113". The remainder of its nominal 113"x113" field is occupied by the coronagraphs and the low resolution spectrometer. We present the instrument optical and mechanical design. We show that the test data, as measured during the test campaigns undertaken at CEA-Saclay, at the Rutherford Appleton Laboratory, and at the NASA Goddard Space Flight Center, indicate that the instrument complies with its design requirements and goals. We also discuss the operational requirements (multiple dithers and exposures) needed for optimal scientific utilization of the MIRIM.Comment: 29 pages, 9 figure

    The MIRI Medium Resolution Spectrometer calibration pipeline

    Get PDF
    The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer (MRS) is the only mid-IR Integral Field Spectrometer on board James Webb Space Telescope. The complexity of the MRS requires a very specialized pipeline, with some specific steps not present in other pipelines of JWST instruments, such as fringe corrections and wavelength offsets, with different algorithms for point source or extended source data. The MRS pipeline has also two different variants: the baseline pipeline, optimized for most foreseen science cases, and the optimal pipeline, where extra steps will be needed for specific science cases. This paper provides a comprehensive description of the MRS Calibration Pipeline from uncalibrated slope images to final scientific products, with brief descriptions of its algorithms, input and output data, and the accessory data and calibration data products necessary to run the pipeline.Comment: 10 pages, 8 figure

    JWST MIRI/MRS in-flight absolute flux calibration and tailored fringe correction for unresolved sources

    Get PDF
    Context. The Medium Resolution Spectrometer (MRS) is one of the four observing modes of JWST/MIRI. Using JWST in-flight data of unresolved (point) sources, we can derive the MRS absolute spectral response function (ASRF) starting from raw data. Spectral fringing, caused by coherent reflections inside the detector arrays, plays a critical role in the derivation and interpretation of the MRS ASRF. The fringe corrections implemented in the current pipeline are not optimal for non-extended sources, and a high density of molecular features particularly inhibits an accurate correction. Aims. In this paper, we present an alternative way to calibrate the MIRI/MRS data. Firstly, we derive a fringe correction that accounts for the dependence of the fringe properties on the MIRI/MRS pupil illumination and detector pixel sampling of the point spread function. Secondly, we derive the MRS ASRF using an absolute flux calibrator observed across the full 5- 28 \ub5m wavelength range of the MRS. Thirdly, we apply the new ASRF to the spectrum of a G dwarf and compare it with the output of the JWST/MIRI default data reduction pipeline. Finally, we examine the impact of the different fringe corrections on the detectability of molecular features in the G dwarf and K giant. Methods. The absolute flux calibrator HD 163466 (A-star) was used to derive tailored point source fringe flats at each of the default dither locations of the MRS. The fringe-corrected point source integrated spectrum of HD 163466 was used to derive the MRS ASRF using a theoretical model for the stellar continuum. A cross-correlation was run to quantify the uncertainty on the detection of CO, SiO, and OH in the K giant and CO in the G dwarf for different fringe corrections. Results. The point-source-tailored fringe correction and ASRF are found to perform at the same level as the current corrections, beating down the fringe contrast to the sub-percent level in the G dwarf in the longer wavelengths, whilst mitigating the alteration of real molecular features. The same tailored solutions can be applied to other MRS unresolved targets. Target acquisition is required to ensure the pointing is accurate enough to apply this method. A pointing repeatability issue in the MRS limits the effectiveness of the tailored fringe flats is at short wavelengths. Finally, resulting spectra require no scaling to make the sub-bands match, and a dichroic spectral leak at 12.2 \ub5m is removed

    JWST/MIRI coronagraphic performances as measured on-sky

    Full text link
    Characterization of directly imaged exoplanets is one of the most eagerly anticipated science functions of the James Webb Space Telescope. MIRI, the mid-IR instrument has the capability to provide unique spatially resolved photometric data points in a spectral range never achieved so far for such objects. We aim to present the very first on-sky contrast measurements of the MIRI's coronagraphs. In addition to a classical Lyot coronagraph at the longest wavelength, this observing mode implements the concept of the four quadrant phase mask for the very first time in a space telescope. We observed single stars together with a series of reference stars to measure raw contrasts as they are delivered on the detector, as well as reference subtracted contrasts. MIRI's coronagraphs achieve raw contrasts greater than 10310^3 at the smallest angular separations (within 11'') and about 10510^5 further out (beyond 565\sim6''). Subtracting the residual diffracted light left unattenuated by the coronagraph has the potential to bring the final contrast down to the background and detector limited noise floor at most angular separations (a few times 10410^4 at less than 11''). MIRI coronagraphs behave as expected from simulations. In particular the raw contrasts for all four coronagraphs are fully consistent with the diffractive model. Contrasts obtained with subtracting reference stars also meet expectations and are fully demonstrated for two four quadrant phase masks (F1065C and F1140C). The worst contrast, measured at F1550C, is very likely due to a variation of the phase aberrations at the primary mirror during the observations, and not an issue of the coronagraph itself. We did not perform reference star subtraction with the Lyot mask at F2300C, but we anticipate that it would bring the contrast down to the noise floor.Comment: submitted to A&
    corecore