Application of a spring-dashpot system to clinical lung tumor motion data
A spring-dashpot system based on the Voigt model was developed to model the
correlation between abdominal respiratory motion and tumor motion during lung
radiotherapy. The model was applied to clinical data comprising 52 treatment
beams from 10 patients, treated on the Mitsubishi Real-Time Radiation Therapy
system, Sapporo, Japan. In Stage 1, model parameters were optimized for
individual patients and beams to determine reference values and to investigate
how well the model can describe the data. In Stage 2, for each patient the
optimal parameters determined for a single beam were applied to data from other
beams to investigate whether a beam-specific set of model parameters is
sufficient to model tumor motion over a course of treatment.
In Stage 1 the baseline root mean square (RMS) residual error for all
individually-optimized beam data was 0.90 plus or minus 0.40 mm. In Stage 2,
patient-specific model parameters based on a single beam were found to model
the tumor position closely, even for irregular beam data, with a mean increase
with respect to Stage 1 values in RMS error of 0.37 mm. On average the obtained
model output for the tumor position was 95% of the time within an absolute
bound of 2.0 mm and 2.6 mm in Stage 1 and 2, respectively.
The model was capable of dealing with baseline, amplitude and frequency
variations of the input data, as well as phase shifts between the input tumor
and output abdominal signals. These results indicate that it may be feasible to
collect patient-specific model parameters during or prior to the first
treatment, and then retain these for the rest of the treatment period. The
model has potential for clinical application during radiotherapy treatment of
lung tumors
Diaphragm as an anatomic surrogate for lung tumor motion
Lung tumor motion due to respiration poses a challenge in the application of
modern three-dimensional conformal radiotherapy. Direct tracking of the lung
tumor during radiation therapy is very difficult without implanted fiducial
markers. Indirect tracking relies on the correlation of the tumor's motion and
the surrogate's motion. The present paper presents an analysis of the
correlation between the tumor motion and the diaphragm motion in order to
evaluate the potential use of diaphragm as a surrogate for tumor motion. We
have analyzed the correlation between diaphragm motion and superior-inferior
lung tumor motion in 32 fluoroscopic image sequences from 10 lung cancer
patients. A simple linear model and a more complex linear model that accounts
for phase delays between the two motions have been used. Results show that the
diaphragm is a good surrogate for tumor motion prediction for most patients,
resulting in an average correlation factor of 0.94 and 0.98 with each model
respectively. The model that accounts for delays leads to an average
localization prediction error of 0.8mm and an error at the 95% confidence level
of 2.1mm. However, for one patient studied, the correlation is much weaker
compared to other patients. This indicates that, before using diaphragm for
lung tumor prediction, the correlation should be examined on a
patient-by-patient basis.Comment: Accepted by Physics in Medicine and Biolog
Real-Time Profiling of Respiratory Motion: Baseline Drift, Frequency Variation and Fundamental Pattern Change
To precisely ablate tumor in radiation therapy, it is important to locate the tumor position in real time during treatment. However, respiration-induced tumor motions are difficult to track. They are semi-periodic and exhibit variations in baseline, frequency and fundamental pattern (oscillatory amplitude and shape). In this study, we try to decompose the above-mentioned components from discrete observations in real time. Baseline drift, frequency (equivalently phase) variation and fundamental pattern change characterize different aspects of respiratory motion and have distinctive clinical indications. Furthermore, smoothness is a valid assumption for each one of these components in their own spaces, and facilitates effective extrapolation for the purpose of estimation and prediction. We call this process 'profiling' to reflect the integration of information extraction, decomposition, processing and recovery. The proposed method has three major ingredients: (1) real-time baseline and phase estimation based on elliptical shape tracking in augmented state space and Poincaré sectioning principle; (2) estimation of the fundamental pattern by unwarping the observation with phase estimate from the previous step; (3) filtering of individual components and assembly in the original temporal-displacement signal space. We tested the proposed method with both simulated and clinical data. For the purpose of prediction, the results are comparable to what one would expect from a human operator. The proposed approach is fully unsupervised and data driven, making it ideal for applications requiring economy, efficiency and flexibility.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85908/1/Fessler14.pd
Cancer-selective, single agent chemoradiosensitising gold nanoparticles
Two nanometre gold nanoparticles (AuNPs), bearing sugar moieties and/or thiol-polyethylene glycol-amine (PEG-amine), were synthesised and evaluated for their in vitro toxicity and ability to radiosensitise cells with 220 kV and 6 MV X-rays, using four cell lines representing normal and cancerous skin and breast tissues. Acute 3 h exposure of cells to AuNPs, bearing PEG-amine only or a 50:50 ratio of alpha-galactose derivative and PEG-amine resulted in selective uptake and toxicity towards cancer cells at unprecedentedly low nanomolar concentrations. Chemotoxicity was prevented by co-administration of N-acetyl cysteine antioxidant, or partially prevented by the caspase inhibitor Z-VAD-FMK. In addition to their intrinsic cancer-selective chemotoxicity, these AuNPs acted as radiosensitisers in combination with 220 kV or 6 MV X-rays. The ability of AuNPs bearing simple ligands to act as cancer-selective chemoradiosensitisers at low concentrations is a novel discovery that holds great promise in developing low-cost cancer nanotherapeutics
An Expanded Multi-scale Monte Carlo Simulation Method for Personalized Radiobiological Effect Estimation in Radiotherapy: a feasibility study
A novel and versatile “bottom-up� approach is developed to estimate the radiobiological effect of clinic
radiotherapy. The model consists of multi-scale Monte Carlo simulations from organ to cell levels. At cellular level, accumulated damages are computed using a spectrum-based accumulation algorithm and predefined cellular damage database. The damage repair mechanism is modeled by an expanded reaction-rate two-lesion kinetic model, which were calibrated through replicating a radiobiological experiment. Multi-scale modeling is then performed on a lung cancer patient under conventional fractionated irradiation. The cell killing effects of two representative voxels (isocenter and peripheral voxel of the tumor) are computed and compared. At microscopic level, the nucleus dose and damage yields vary among all nucleuses within the voxels. Slightly larger percentage of cDSB yield is observed for the peripheral voxel (55.0%) compared to the isocenter one (52.5%). For isocenter voxel, survival fraction increase monotonically at reduced oxygen environment. Under an extreme anoxic condition (0.001%), survival fraction is calculated to be 80% and the hypoxia reduction factor reaches a maximum value of 2.24. In conclusion, with biological-related variations, the proposed multi-scale approach
is more versatile than the existing approaches for evaluating personalized radiobiological effects in
radiotherapy
Search for Branons at LEP
We search, in the context of extra-dimension scenarios, for the possible
existence of brane fluctuations, called branons. Events with a single photon or
a single Z-boson and missing energy and momentum collected with the L3 detector
in e^+ e^- collisions at centre-of-mass energies sqrt{s}=189-209$ GeV are
analysed. No excess over the Standard Model expectations is found and a lower
limit at 95% confidence level of 103 GeV is derived for the mass of branons,
for a scenario with small brane tensions. Alternatively, under the assumption
of a light branon, brane tensions below 180 GeV are excluded
Study of Spin and Decay-Plane Correlations of W Bosons in the e+e- -> W+W- Process at LEP
Data collected at LEP at centre-of-mass energies \sqrt(s) = 189 - 209 GeV are
used to study correlations of the spin of W bosons using e+e- -> W+W- -> lnqq~
events. Spin correlations are favoured by data, and found to agree with the
Standard Model predictions. In addition, correlations between the W-boson decay
planes are studied in e+e- -> W+W- -> lnqq~ and e+e- -> W+W- -> qq~qq~ events.
Decay-plane correlations, consistent with zero and with the Standard Model
predictions, are measured
Search for Branons at LEP
We search, in the context of extra-dimension scenarios, for the possible
existence of brane fluctuations, called branons. Events with a single photon or
a single Z-boson and missing energy and momentum collected with the L3 detector
in e^+ e^- collisions at centre-of-mass energies sqrt{s}=189-209$ GeV are
analysed. No excess over the Standard Model expectations is found and a lower
limit at 95% confidence level of 103 GeV is derived for the mass of branons,
for a scenario with small brane tensions. Alternatively, under the assumption
of a light branon, brane tensions below 180 GeV are excluded
Ultrarelativistic sources in nonlinear electrodynamics
The fields of rapidly moving sources are studied within nonlinear
electrodynamics by boosting the fields of sources at rest. As a consequence of
the ultrarelativistic limit the delta-like electromagnetic shock waves are
found. The character of the field within the shock depends on the theory of
nonlinear electrodynamics considered. In particular, we obtain the field of an
ultrarelativistic charge in the Born-Infeld theory.Comment: 10 pages, 3 figure
Measurement of the Cross Section for Open-Beauty Production in Photon-Photon Collisions at LEP
The cross section for open-beauty production in photon-photon collisions is
measured using the whole high-energy and high-luminosity data sample collected
by the L3 detector at LEP. This corresponds to 627/pb of integrated luminosity
for electron-positron centre-of-mass energies from 189GeV to 209GeV. Events
containing b quarks are identified through their semi-leptonic decay into
electrons or muons. The e+e- -> e+e-b b~X cross section is measured within our
fiducial volume and then extrapolated to the full phase space. These results
are found to be in significant excess with respect to Monte Carlo predictions
and next-to-leading order QCD calculations
- …