110 research outputs found

    Optical microscopy via spectral modifications of a nano-antenna

    Full text link
    The existing optical microscopes form an image by collecting photons emitted from an object. Here we report on the experimental realization of microscopy without the need for direct optical communication with the sample. To achieve this, we have scanned a single gold nanoparticle acting as a nano-antenna in the near field of a sample and have studied the modification of its intrinsic radiative properties by monitoring its plasmon spectrum.Comment: 6 pages, 4 figures (color

    Resolution and enhancement in nanoantenna-based fluorescence microscopy

    Full text link
    Single gold nanoparticles can act as nanoantennas for enhancing the fluorescence of emitters in their near-fields. Here we present experimental and theoretical studies of scanning antenna-based fluorescence microscopy as a function of the diameter of the gold nanoparticle. We examine the interplay between fluorescence enhancement and spatial resolution and discuss the requirements for deciphering single molecules in a dense sample. Resolutions better than 20 nm and fluorescence enhancement up to 30 times are demonstrated experimentally. By accounting for the tip shaft and the sample interface in finite-difference time-domain calculations, we explain why the measured fluorescence enhancements are higher in the presence of an interface than the values predicted for a homogeneous environment.Comment: 10 pages, 3 figures. accepted for publication in Nano Letter

    Comparison of established and emerging biodosimetry assays

    Get PDF
    Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3-0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5-4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools

    Selective nanomanipulation using optical forces

    Full text link
    We present a detailed theoretical study of the recent proposal for selective nanomanipulation of nanometric particles above a substrate using near-field optical forces [Chaumet {\it et al.} Phys. Rev. Lett. {\bf 88}, 123601 (2002)]. Evanescent light scattering at the apex of an apertureless near-field probe is used to create an optical trap. The position of the trap is controlled on a nanometric scale via the probe and small objects can be selectively trapped and manipulated. We discuss the influence of the geometry of the particles and the probe on the efficiency of the trap. We also consider the influence of multiple scattering among the particles on the substrate and its effect on the robustness of the trap.Comment: 12 pages, 17 figure

    Near-field examination of perovskite-based superlenses and superlens-enhanced probe-object coupling

    Get PDF
    A planar slab of negative index material works as a superlens with sub-diffraction-limited imaging resolution, since propagating waves are focused and, moreover, evanescent waves are reconstructed in the image plane. Here, we demonstrate a superlens for electric evanescent fields with low losses using perovskites in the mid-infrared regime. The combination of near-field microscopy with a tunable free-electron laser allows us to address precisely the polariton modes, which are critical for super-resolution imaging. We spectrally study the lateral and vertical distributions of evanescent waves around the image plane of such a lens, and achieve imaging resolution of wavelength/14 at the superlensing wavelength. Interestingly, at certain distances between the probe and sample surface, we observe a maximum of these evanescent fields. Comparisons with numerical simulations indicate that this maximum originates from an enhanced coupling between probe and object, which might be applicable for multifunctional circuits, infrared spectroscopy, and thermal sensors.Comment: 20 pages, 6 figures, published as open access article in Nature Communications (see http://www.nature.com/ncomms/

    Nanomechanical properties of α-synuclein amyloid fibrils: a comparative study by nanoindentation, harmonic force microscopy, and Peakforce QNM

    Get PDF
    We report on the use of three different atomic force spectroscopy modalities to determine the nanomechanical properties of amyloid fibrils of the human α-synuclein protein. α-Synuclein forms fibrillar nanostructures of approximately 10 nm diameter and lengths ranging from 100 nm to several microns, which have been associated with Parkinson's disease. Atomic force microscopy (AFM) has been used to image the morphology of these protein fibrils deposited on a flat surface. For nanomechanical measurements, we used single-point nanoindentation, in which the AFM tip as the indenter is moved vertically to the fibril surface and back while the force is being recorded. We also used two recently developed AFM surface property mapping techniques: Harmonic force microscopy (HarmoniX) and Peakforce QNM. These modalities allow extraction of mechanical parameters of the surface with a lateral resolution and speed comparable to tapping-mode AFM imaging. Based on this phenomenological study, the elastic moduli of the α-synuclein fibrils determined using these three different modalities are within the range 1.3-2.1 GPa. We discuss the relative merits of these three methods for the determination of the elastic properties of protein fibrils, particularly considering the differences and difficulties of each method

    Seismic detection of the martian core

    Get PDF
    Clues to a planet's geologic history are contained in its interior structure, particularly its core. We detected reflections of seismic waves from the core-mantle boundary of Mars using InSight seismic data and inverted these together with geodetic data to constrain the radius of the liquid metal core to 1830 +/- 40 kilometers. The large core implies a martian mantle mineralogically similar to the terrestrial upper mantle and transition zone but differing from Earth by not having a bridgmanite-dominated lower mantle. We inferred a mean core density of 5.7 to 6.3 grams per cubic centimeter, which requires a substantial complement of light elements dissolved in the iron-nickel core. The seismic core shadow as seen from InSight's location covers half the surface of Mars, including the majority of potentially active regions-e.g., Tharsis-possibly limiting the number of detectable marsquakes.This is InSight contribution 200. We acknowledge NASA, CNES, and partner agencies and institutions (UKSA, SSO, ESA-PRODEX, DLR, JPL, IPGP-CNRS, ETHZ, IC, and MPS-MPG) for the development of SEIS. Numerical simulations were supported by a grant from the Swiss National Supercomputing Centre (CSCS) under project ID s922 as well as HPC resources of CINES under the allocation A0090407341, made by GENCI. We thank B. Dintrans, director of CINES, for his efficient handling of our request for computational time. Figures were created using matplotlib (83), seismic data processing was done in ObsPy (84), and numerical evaluation was done in NumPy and SciPy (85, 86). Funding: S.C.S., A.K., D.G., J.C., A.C.D., G.Z., and N.D. acknowledge support from ETHZ through the ETH+ funding scheme (ETH+2 19-1: “Planet MARS”). S.C.S. acknowledges funding from ETH research grant ETH-10 17-3. W.B.B., A.G.M., M.P.P., and S.E.S. were supported by the NASA InSight mission and funds from the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration (80NM0018D0004). D.A. has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation program (grant agreement 724690). The French teams acknowledge support from CNES as well as Agence Nationale de la Recherche (ANR-14-CE36-0012-02 and ANR-19-CE31-0008-08). A.R. was financially supported by the Belgian PRODEX program managed by the European Space Agency in collaboration with the Belgian Federal Science Policy Office. M.S. wishes to thank SANIMS (RTI2018-095594-B-I00). M.v.D. received support from the ERC under the European Union’s Horizon 2020 program (grant no. 714069). D.S. and C.S. acknowledge funding from ETH research grant ETH-06 17-02. J.C.E.I. acknowledges support from NASA grant 80NSSC18K1633. N.S., D.K., Q.H., R.M., V.L., and A.G.M. acknowledge NASA grant 80NSSC18K1628 for support. V.L. acknowledges support from the Packard Foundation. W.T.P. and C.C. received funding from the UK Space Agency, grant ST/S001239/1. A.H. was funded by the UK Space Agency (grant ST/R002096/1). A.-C.P. acknowledges the financial support and endorsement from the DLR Management Board Young Research Group Leader Program and the Executive Board Member for Space Research and Technology. Author contributions: S.C.S., D.G., S.C., R.F.G., Q.H., D.K., V.L., M.S., N.S., D.S., É.S., C.S., and G.Z. analyzed the seismic data and made ScS arrival time picks. S.C.S., P.L., D.G., Z.X., C.C., and W.T.P. performed the statistical analysis of the observed signals. S.C.S., Q.H., N.S., R.M., and A.G.M. identified the arrivals as ScS waves based on interior models from A.K., H.S., and A.R. A.K., M.D., A.C.D., and H.S. performed the inversions. S.C.S., A.K., P.L., D.G., D.A., J.C.E.I., M.K., C.P., A.-C.P., A.R., T.G., and S.E.S. participated and contributed to the interpretation of the results. Review of the continuous data and detection of marsquakes was done by S.C.S., S.C., G.Z., C.C., N.D., J.C., M.v.D., T.K., M.P., and A.H. with operational support by É.B., C.P., and P.M.D. S.C.S. and A.K. wrote the central part of the paper with contributions from H.S., N.S., D.A., J.C.E.I., A.G.M., A.-C.P., A.R., J.C., and M.v.D. J.C.E.I., R.M., M.K., and V.L. reviewed the contributions to the supplementary materials. The InSight mission is managed by W.B.B., M.P.P., and S.E.S. The SEIS instrument development was led by P.L., D.G., W.T.P., and W.B.B. Supplementary section 1 was written by M.S., D.S., and É.S. with contributions from S.C.S., C.S., and Z.X. Supplementary section 2 was written by D.K. and V.L. with contributions from J.C.E.I. and N.S. Supplementary section 3 was written by M.S. and É.S. Supplementary section 4 was written by R.F.G. with contributions from M.D. Supplementary section 5 was written by Q.H. with contributions from N.S. Supplementary section 6 was written by S.C.S. with contributions from the authors of the other supplements. Supplementary section 7 was written by Z.X. and C.C. with contributions from P.L. and W.T.P. Supplementary section 8 was written by A.K., M.D., A.C.D., and H.S. Supplementary section 9 was written by M.D. Supplementary section 10 was written by A.C.D., A.K., and M.D. Supplementary section 11 was written by D.A. and A.R. with contributions from A.K. Competing interests: The authors declare that they have no competing interests. Data and materials availability: We thank the operators of JPL, SISMOC, MSDS, IRIS-DMC, and PDS for providing SEED SEIS data (87). Three hundred interior models derived in this study are available from MSDS (88)

    Características del liderazgo pedagógico del directivo docente de la I.E. de Jesús del municipio de Concordia

    Get PDF
    Esta investigación abordó el liderazgo pedagógico, específicamente el liderazgo directivo, su papel dentro del proceso pedagógico de la institución educativa está justificado por la relevancia que tiene en la gestión curricular, entre otras funciones, pues permite que las instituciones educativas - I.E marchen adecuadamente y alcancen mayores logros para todos los estudiantes. El objetivo consistió en identificar las características del liderazgo pedagógico del directivo docente de la I.E de Jesús del municipio de Concordia. Para esto se consideró una investigación enmarcada dentro del enfoque cualitativo de tipo descriptivo, el método fue estudio de caso. Los instrumentos que se utilizaron fueron, la entrevista, el diario de campo y el grupo focal. Con base en los resultados obtenidos en las entrevistas se destacan aspectos importantes de la comunicación y el liderazgo, vinculados a la gestión administrativa de la I.E. La investigación muestra la importancia que tiene el liderazgo pedagógico del directivo docente como elemento clave en el desarrollo y funcionamiento pedagógico-curricular de la I.E.This research addressed pedagogical leadership, such as one that focuses on the directive role, specifically on his role in the educational process on the educative institution; the relevance it's justified for this process for function properly on the institutions to and achieve greater achievements for all students. The objective was to identify the pedagogical leadership from the educative director of the Educative Institution of Jesus from the Concordia municipality. For this, was considered an investigation framed within the qualitative approach of descriptive type, the method was a study case. The instruments used were interview, field diaries and focus group. Based on the interview results obtained, important aspects of communication and leadership were highlighted, linked to the development processes on the educative institution. The research shows the importance on a pedagogical leadership of the teaching director as a key element within the institution.Magíster en EducaciónMaestrí

    Caracterização morfológica de nanocristais de celulose por microscopia de força atômica

    Get PDF
    RESUMO O isolamento de nanocristais de celulose (CNCs) de fibras vegetais é uma alternativa promissora para sua aplicação como reforço em matrizes poliméricas. A caracterização dos CNCs é fundamental para a confiabilidade da técnica, além de determinar as aplicações possíveis a partir de cada tipo de fibra. A partir da técnica de microscopia de força atômica, um estudo da morfologia e distribuição dos CNCs de semente de manga, vagem de algaroba, pseudocaule da bananeira e fibra do mesocarpo de dendê foi realizado neste trabalho. Os CNCs foram obtidos via reação hidrolítica com ácido sulfúrico em concentrações que variaram de acordo com a fonte da fibra. Os resultados obtidos revelaram dimensões variando de 300 a 500 nm em comprimento e 4 a 16 nm em diâmetro. A apresentação morfológica em forma de agulha demonstrou que o isolamento das fibras de celulose em CNCs foi efetiva. A razão de aspecto associada à formação cilíndrica em agulha dos CNCs isolados evidenciou o alto potencial das fontes de dendê e de vagem de algaroba para o reforço de bionanocompósitos
    corecore