136 research outputs found

    Endoscopic Saphenous harvesting with an Open CO2 System (ESOS) trial for coronary artery bypass grafting surgery: study protocol for a randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In coronary artery bypass grafting surgery, arterial conduits are preferred because of more favourable long-term patency and outcome. Anyway <it>the greater saphenous vein </it>continues to be the most commonly used bypass conduit. <it>Minimally invasive endoscopic saphenous vein harvesting </it>is increasingly being investigated in order to reduce the morbidity associated with conventional open vein harvesting, includes postoperative leg wound complications, pain and patient satisfaction. However, to date the short and the long-term benefits of the endoscopic technique remain controversial. This study provides an interesting opportunity to address this gap in the literature.</p> <p>Methods/Design</p> <p><b>Endoscopic Saphenous harvesting with an Open CO<sub>2 </sub>System </b>trial includes two parallel vein harvesting arms in coronary artery bypass grafting surgery. It is an interventional, single centre, prospective, randomized, safety/efficacy, cost/effectiveness study, in adult patients with elective planned and first isolated coronary artery disease. A simple size of 100 patients for each arm will be required to achieve 80% statistical power, with a significant level of 0.05, for detecting most of the formulated hypotheses. A six-weeks leg wound complications rate was assumed to be 20% in the conventional arm and less of 4% in the endoscopic arm. Previously quoted studies suggest a first-year vein-graft failure rate of about 20% with an annual occlusion rate of 1% to 2% in the first six years, with practically no difference between the endoscopic and conventional approaches. Similarly, the results on event-free survival rates for the two arms have barely a 2-3% gap. Assuming a 10% drop-out rate and a 5% cross-over rate, the goal is to enrol 230 patients from a single Italian cardiac surgery centre.</p> <p>Discussion</p> <p>The goal of this prospective randomized trial is to compare and to test improvement in wound healing, quality of life, safety/efficacy, cost-effectiveness, short and long-term outcomes and vein-graft patency after endoscopic open CO<sub>2 </sub>harvesting system versus conventional vein harvesting.</p> <p>The expected results are of high clinical relevance and will show the safety/efficacy or non-inferiority of one treatment approach in terms of vein harvesting for coronary artery bypass grafting surgery.</p> <p>Trial registration</p> <p>www.clinicalTrials.gov <a href="http://www.clinicaltrials.gov/ct2/show/NCT01121341">NCT01121341</a>.</p

    Intelligent image-based in situ single-cell isolation

    Get PDF
    Quantifying heterogeneities within cell populations is important for many fields including cancer research and neurobiology; however, techniques to isolate individual cells are limited. Here, we describe a high-throughput, non-disruptive, and cost-effective isolation method that is capable of capturing individually targeted cells using widely available techniques. Using high-resolution microscopy, laser microcapture microscopy, image analysis, and machine learning, our technology enables scalable molecular genetic analysis of single cells, targetable by morphology or location within the sample.Peer reviewe

    The Post-thrombotic Syndrome-Prevention and Treatment: VAS-European Independent Foundation in Angiology/Vascular Medicine Position Paper.

    Get PDF
    Importance: The post-thrombotic syndrome (PTS) is the most common long-term complication of deep vein thrombosis (DVT), occurring in up to 40-50% of cases. There are limited evidence-based approaches for PTS clinical management. Objective: To provide an expert consensus for PTS diagnosis, prevention, and treatment. Evidence-review: MEDLINE, Cochrane Database review, and GOOGLE SCHOLAR were searched with the terms "post-thrombotic syndrome" and "post-phlebitic syndrome" used in titles and abstracts up to September 2020. Filters were: English, Controlled Clinical Trial / Systematic Review / Meta-Analysis / Guideline. The relevant literature regarding PTS diagnosis, prevention and treatment was reviewed and summarized by the evidence synthesis team. On the basis of this review, a panel of 15 practicing angiology/vascular medicine specialists assessed the appropriateness of several items regarding PTS management on a Likert-9 point scale, according to the RAND/UCLA method, with a two-round modified Delphi method. Findings: The panelists rated the following as appropriate for diagnosis: 1-the Villalta scale; 2- pre-existing venous insufficiency evaluation; 3-assessment 3-6 months after diagnosis of iliofemoral or femoro-popliteal DVT, and afterwards periodically, according to a personalized schedule depending on the presence or absence of clinically relevant PTS. The items rated as appropriate for symptom relief and prevention were: 1- graduated compression stockings (GCS) or elastic bandages for symptomatic relief in acute DVT, either iliofemoral, popliteal or calf; 2-thigh-length GCS (30-40 mmHg at the ankle) after ilio-femoral DVT; 3- knee-length GCS (30-40 mmHg at the ankle) after popliteal DVT; 4-GCS for different length of times according to the severity of periodically assessed PTS; 5-catheter-directed thrombolysis, with or without mechanical thrombectomy, in patients with iliofemoral obstruction, severe symptoms, and low risk of bleeding. The items rated as appropriate for treatment were: 1- thigh-length GCS (30-40 mmHg at the ankle) after iliofemoral DVT; 2-compression therapy for ulcer treatment; 3- exercise training. The role of endovascular treatment (angioplasty and/or stenting) was rated as uncertain, but it could be considered for severe PTS only in case of stenosis or occlusion above the inguinal ligament, followed by oral anticoagulation. Conclusions and relevance: This position paper can help practicing clinicians in PTS management

    Medico-legal autopsy in postoperative hemodynamic collapse following coronary artery bypass surgery

    Get PDF
    Sudden unexpected postoperative hemodynamic collapse with a high mortality develops in 1–3% of patients undergoing coronary artery bypass surgery (CABG). The contribution of surgical graft complications to this serious condition is poorly known and their demonstration at autopsy is a challenging task. Isolated CABG was performed in 8,807 patients during 1988–1999. Of the patients, 76 (0.9%) developed sudden postoperative hemodynamic collapse resulting in subsequent emergency reopening of the median sternotomy and open cardiac massage. Further emergency reoperation could be performed in 62 (82%) whereas 14 patients died prior to reoperation and a further 21 did not survive the reoperation or died a few days later. All 35 (46%) patients who did not survive were subjected to medico-legal autopsy combined with postmortem cast angiography. By combining clinical data with autopsy and angiography data, various types of graft complications were observed in 27 (36%, 1.3 per patient) of the 76 patients with hemodynamic collapse. There were no significant differences in the frequency (33 vs. 40%) or number of complicated grafts per patient (1.2 vs. 1.4) between those who survived reoperation and who did not. Autopsy detected 25 major and minor findings not diagnosed clinically. Postmortem cast angiography visualized 2 graft twists not possible to detect by autopsy dissection only. Surgical graft complications were the most frequent single cause for sudden postoperative hemodynamic collapse in CABG patients leading to a fatal outcome in almost half of the cases. Postmortem angiography improved the accuracy of autopsy diagnostics of graft complications

    High-Density Real-Time PCR-Based in Vivo Toxicogenomic Screen to Predict Organ-Specific Toxicity

    Get PDF
    Toxicogenomics, based on the temporal effects of drugs on gene expression, is able to predict toxic effects earlier than traditional technologies by analyzing changes in genomic biomarkers that could precede subsequent protein translation and initiation of histological organ damage. In the present study our objective was to extend in vivo toxicogenomic screening from analyzing one or a few tissues to multiple organs, including heart, kidney, brain, liver and spleen. Nanocapillary quantitative real-time PCR (QRT-PCR) was used in the study, due to its higher throughput, sensitivity and reproducibility, and larger dynamic range compared to DNA microarray technologies. Based on previous data, 56 gene markers were selected coding for proteins with different functions, such as proteins for acute phase response, inflammation, oxidative stress, metabolic processes, heat-shock response, cell cycle/apoptosis regulation and enzymes which are involved in detoxification. Some of the marker genes are specific to certain organs, and some of them are general indicators of toxicity in multiple organs. Utility of the nanocapillary QRT-PCR platform was demonstrated by screening different references, as well as discovery of drug-like compounds for their gene expression profiles in different organs of treated mice in an acute experiment. For each compound, 896 QRT-PCR were done: four organs were used from each of the treated four animals to monitor the relative expression of 56 genes. Based on expression data of the discovery gene set of toxicology biomarkers the cardio- and nephrotoxicity of doxorubicin and sulfasalazin, the hepato- and nephrotoxicity of rotenone, dihydrocoumarin and aniline, and the liver toxicity of 2,4-diaminotoluene could be confirmed. The acute heart and kidney toxicity of the active metabolite SN-38 from its less toxic prodrug, irinotecan could be differentiated, and two novel gene markers for hormone replacement therapy were identified, namely fabp4 and pparg, which were down-regulated by estradiol treatment

    [Accepted Manuscript] Left Main Revascularization With PCI or CABG in Patients With Chronic Kidney Disease: EXCEL Trial.

    Get PDF
    The optimal revascularization strategy for patients with left main coronary artery disease (LMCAD) and chronic kidney disease (CKD) remains unclear. This study investigated the comparative effectiveness of percutaneous coronary intervention (PCI) versus coronary artery bypass graft (CABG) surgery in patients with LMCAD and low or intermediate anatomical complexity according to baseline renal function from the multicenter randomized EXCEL (Evaluation of XIENCE Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) trial. CKD was defined as an estimated glomerular filtration rate &lt;60 ml/min/1.73 m2 using the CKD Epidemiology Collaboration equation. Acute renal failure (ARF) was defined as a serum creatinine increase ≥5.0 mg/dl from baseline or a new requirement for dialysis. The primary composite endpoint was the composite of death, myocardial infarction (MI), or stroke at 3-year follow-up. CKD was present in 361 of 1,869 randomized patients (19.3%) in whom baseline estimated glomerular filtration rate was available. Patients with CKD had higher 3-year rates of the primary endpoint compared with those without CKD (20.8% vs. 13.5%; hazard ratio [HR]: 1.60; 95% confidence interval [CI]: 1.22 to 2.09; p = 0.0005). ARF within 30 days occurred more commonly in patients with compared with those without CKD (5.0% vs. 0.8%; p &lt; 0.0001), and was strongly associated with the 3-year risk of death, stroke, or MI (50.7% vs. 14.4%; HR: 4.59; 95% CI: 2.73 to 7.73; p &lt; 0.0001). ARF occurred less commonly after revascularization with PCI compared with CABG both in patients with CKD (2.3% vs. 7.7%; HR: 0.28; 95% CI: 0.09 to 0.87) and in those without CKD (0.3% vs. 1.3%; HR: 0.20; 95% CI: 0.04 to 0.90; pinteraction = 0.71). There were no significant differences in the rates of the primary composite endpoint after PCI and CABG in patients with CKD (23.4% vs. 18.1%; HR: 1.25; 95% CI: 0.79 to 1.98) and without CKD (13.4% vs. 13.5%; HR: 0.97; 95% CI: 0.73 to 1.27; pinteraction = 0.38). Patients with CKD undergoing revascularization for LMCAD in the EXCEL trial had increased rates of ARF and reduced event-free survival. ARF occurred less frequently after PCI compared with CABG. There were no significant differences between PCI and CABG in terms of death, stroke, or MI at 3 years in patients with and without CKD. (EXCEL Clinical Trial [EXCEL]; NCT01205776)
    corecore