100 research outputs found

    Use of quadrupole time-of-flight mass spectrometry for proposal of transformation products of the herbicide bromacil after water chlorination

    Get PDF
    The herbicide bromacil has been extensively used in the Spanish Mediterranean region, and although plant protection products containing bromacil have been withdrawn by the European Union, this compound is still frequently detected in surface and ground water of this area. However, the fast and complete disappearance of this compound has been observed in water intended for human consumption, after it has been subjected to chlorination. There is a concern about the possible degradation products formed, since they might be present in drinking water and might be hazardous. In this work, the sensitive full-spectrum acquisition, high resolution and exact mass capabilities of hybrid quadrupole time-of-flight (QTOF) mass spectrometry have allowed the discovery and proposal of structures of transformation products (TPs) of bromacil in water subjected to chlorination. Different ground water samples spiked at 0.5 µg/mL were subjected to the conventional chlorination procedure applied to drinking waters, sampling 2-mL aliquots at different time intervals (1, 10 and 30 min). The corresponding non-spiked water was used as control sample in each experiment. Afterwards, 50 μL of the water was directly injected into an ultra-high-pressure liquid chromatography (UHPLC)/electrospray ionization (ESI)-(Q)TOF system. The QTOF instrument enabled the simultaneous recording of two acquisition functions at different collision energies (MSE approach): the low-energy (LE) function, fixed at 4 eV, and the high-energy (HE) function, with a collision energy ramp from 15 to 40 eV. This approach enables the simultaneous acquisition of both parent (deprotonated and protonated molecules) and fragment ions in a single injection. The low mass errors observed for the deprotonated and protonated molecules (detected in LE function) allowed the assignment of a highly probable molecular formula. Fragment ions and neutral losses were investigated in both LE and HE spectra to elucidate the structures of the TPs found. For those compounds that displayed poor fragmentation, product ion scan (MS/MS) experiments were also performed. On processing the data with specialized software (MetaboLynx), four bromacil TPs were detected and their structures were elucidated. To our knowledge, two of them had not previously been reported

    Analytical strategy to investigate 3,4-methylenedioxypyrovalerone (MDPV) metabolites in consumers’ urine by high-resolution mass spectrometry

    Get PDF
    The potential of high-resolution mass spectrometry (HRMS) for the investigation of human in vivo metabolism of 3,4-methylenedioxypyrovalerone (MDPV) using urine collected from a consumer (this is, in non-controlled experiments) has been investigated. As a control sample was not available, the common approach based on the comparison of a control/blank sample and samples collected after drug intake could not be used. Alternatively, an investigation based on common fragmentation pathways was applied, assuming that most metabolites share some fragments with the parent drug. An extension of this approach was also applied based on the fragmentation pathway of those metabolites identified in urine samples in the first step. The use of MSE experiments (sequential acquisition of mass spectra at low and high collision energy) has been crucial to this aim as it allowed promoting fragmentation in the collision cell without any previous precursor ion selection. MDPV belongs to the group of new psychoactive substances (NPS), being known as the “cannibal drug”. This substance is being abused more and more and is associated with dangerous side effects. The human metabolites (both phase I and phase II) were detected and tentatively identified by accurate mass full-spectrum measurements using ultra-high performance liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry (UHPLC-QTOF MS). Following this strategy, up to 10 phase I metabolites, together with some glucuronides and sulphates, were detected and tentative structures were proposed. Several compounds identified in this work have not been previously reported in the literature.MINECO (CTQ2012-36189) i Generalitat Valenciana (research group of excellence PROMETEOII/2014/023; ISIC Envi-Food 2014/016). Spanish Health National System is acknowledged for O. J. Pozo contract (MS10/00576)

    Determination of selected endogenous anabolic androgenic steroids and ratios in urine by ultra high performance liquid chromatography tandem mass spectrometry and isotope pattern deconvolution

    Get PDF
    An isotope dilution mass spectrometry (IDMS) method for the determination of selected endogenous anabolic androgenic steroids (EAAS) in urine by UHPLC–MS/MS has been developed using the isotope pattern deconvolution (IPD) mathematical tool. The method has been successfully validated for testosterone, epitestosterone, androsterone and etiocholanolone, employing their respective deuterated analogs using two certified reference materials (CRM). Accuracy was evaluated as recovery of the certified values and ranged from 75% to 108%. Precision was assessed in intraday (n = 5) and interday (n = 4) experiments, with RSDs below 5% and 10% respectively. The method was also found suitable for real urine samples, with limits of detection (LOD) and quantification (LOQ) below the normal urinary levels. The developed method meets the requirements established by the World Anti-Doping Agency for the selected steroids for Athlete Biological Passport (ABP) measurements, except in the case of androsterone, which is currently under study

    Pesticide residues and transformation products in groundwater from a Spanish agricultural region on the Mediterranean Coast

    Get PDF
    An overview is given on the presence and changes over time of pesticide residues in groundwater from the Valencia region, one of the most important citrus cultivation sites of southern Europe. A multiresidue LC-MS/MS method was applied for the screening of around 50 pesticides in 75 water samples collected during 2000. The herbicides simazine, terbuthylazine, bromacil, terbumeton, and diuron were the most frequently detected compounds. On the basis of compounds detected in these samples, another method that focused on 30 herbicides and relevant transformation products (TPs) was developed and applied to around 80 water samples collected during 2003. Simazine was the most frequently found compound followed by several triazine metabolites. Data for this paper show the vulnerability of groundwater in this area to herbicide applications and illustrate the importance of including pesticide TPs in environmental monitoring programmes, as four out of the five compounds most frequently detected were pesticide TP

    Potential of atmospheric pressure chemical ionization source in gas chromatography tandem mass spectrometry for the screening of urinary exogenous androgenic anabolic steroids

    Get PDF
    The atmospheric pressure chemical ionization (APCI) source for gas chromatography-mass spectrometry analysis has been evaluated for the screening of 16 exogenous androgenic anabolic steroids (AAS) in urine. The sample treatment is based on the strategy currently applied in doping control laboratories i.e. enzymatic hydrolysis, liquid–liquid extraction (LLE) and derivatization to form the trimethylsilyl ether-trimethylsilyl enol ether (TMS) derivatives. These TMS derivatives are then analyzed by gas chromatography tandem mass spectrometry using a triple quadrupole instrument (GC-QqQ MS/MS) under selected reaction monitoring (SRM) mode. The APCI promotes soft ionization with very little fragmentation resulting, in most cases, in abundant [M + H]+ or [M + H-2TMSOH]+ ions, which can be chosen as precursor ions for the SRM transitions, improving in this way the selectivity and sensitivity of the method. Specificity of the transitions is also of great relevance, as the presence of endogenous compounds can affect the measurements when using the most abundant ions. The method has been qualitatively validated by spiking six different urine samples at two concentration levels each. Precision was generally satisfactory with RSD values below 25 and 15% at the low and high concentration level, respectively. Most the limits of detection (LOD) were below 0.5 ng mL−1. Validation results were compared with the commonly used method based on the electron ionization (EI) source. EI analysis was found to be slightly more repeatable whereas lower LODs were found for APCI. In addition, the applicability of the developed method has been tested in samples collected after the administration of 4-chloromethandienone. The highest sensitivity of the APCI method for this compound, allowed to increase the period in which its administration can be detected.Ministry of Education and Science, Spain, in the project DEP2011-28573-C02-01/02 Generalitat Valenciana (Research Group of Excellence Prometeo II/2014/023; ISIC EnviFood 2012/016

    Untargeted metabolomics in doping control : detection of new markers of testosterone misuse by ultrahigh performance liquid chromatography coupled to high-resolution mass spectrometry

    Get PDF
    The use of untargeted metabolomics for the discovery of markers is a promising and virtually unexplored tool in the doping control field. Hybrid quadrupole time-of-flight (QTOF) and hybrid quadrupole Orbitrap (Q Exactive) mass spectrometers, coupled to ultrahigh pressure liquid chromatography, are excellent tools for this purpose. In the present work, QTOF and Q Exactive have been used to look for markers for testosterone cypionate misuse by means of untargeted metabolomics. Two different groups of mine samples were analyzed, collected before and after the intramuscular administration of testosterone cypionate. In order to avoid analyte losses in the sample treatment, samples were just 2-fold diluted with water and directly injected into the chromatographic system. Samples were analyzed in both positive and negative ionization modes. Data from both systems were treated under untargeted metabolomic strategies using XCMS application and multivariate analysis. Results from the two mass spectrometers differed in the number of detected features, but both led to the same potential marker for the particular testosterone ester misuse. The in-depth study of the MS and MS/MS behavior of this marker allowed for the establishment of 1-cydopentenoylglycine as a feasible structure. The putative structure was confirmed by comparison with synthesized material. This potential marker seems to come from the metabolism of the cypionic acid release after hydrolysis of the administered ester. Its suitability for doping control has been evaluated

    The Tryptophan System in Cocaine-Induced Depression

    Get PDF
    Major depression disorder (MDD) is the most prevalent psychiatric comorbid condition in cocaine use disorder (CUD). The comorbid MDD might be primary-MDD (CUD-primary-MDD) or cocaine-induced MDD (CUD-induced-MDD), and their accurate diagnoses and treatment is a challenge for improving prognoses. This study aimed to assess the tryptophan/serotonin (Trp/5-HT) system with the acute tryptophan depletion test (ATD), and the kynurenine pathway in subjects with CUD-primary-MDD, CUD-induced-MDD, MDD and healthy controls. The ATD was performed with a randomized, double-blind, crossover, and placebo-controlled design. Markers of enzymatic activity of indoleamine 2,3-dioxygenase/tryptophan 2,3-dioxygenase, kynurenine aminotransferase (KAT) and kynureninase were also established. Following ATD, we observed a decrease in Trp levels in all groups. Comparison between CUD-induced-MDD and MDD revealed significant differences in 5-HT plasma concentrations (512 + 332 ng/mL vs. 107 + 127 ng/mL, p = 0.039) and the Kyn/5-HT ratio (11 + 15 vs. 112 + 136; p = 0.012), whereas there were no differences between CUD-primary-MDD and MDD. Effect size coefficients show a gradient for all targeted markers (d range 0.72-1.67). Results suggest different pathogenesis for CUD-induced-MDD, with lower participation of the tryptophan system, probably more related to other neurotransmitter pathways and accordingly suggesting the need for a different pharmacological treatment approach

    Evaluation of uncertainty sources in the determination of testosterone in urine by calibration-based and isotope dilution quantification using ultra high performance liquid chromatography tandem mass spectrometry

    Get PDF
    Three quantification methodologies, namely calibration with internal standard (Cal-IS, non-weighted), weighted calibration with internal standard (wCal-IS) and isotope pattern deconvolution (IPD) have been used for the determination of testosterone in urine by LC-MS/MS. Uncertainty has been calculated and compared for the three methodologies through intra- and inter-laboratory reproducibility assays. IPD showed the best performance for the intra-laboratory reproducibility, with RSD and combined uncertainty values below 4% and 9% respectively. wCal-IS showed similar performance, while Cal-IS where not constant and clearly worse at the lowest concentration assayed (2 ng/mL) reaching RSD values up to 16%. The inter-laboratory assay indicated similar results although wCal-IS RSD (20%) was higher than IPD (10%) and Cal-IS get worse with RSD higher than 40% for the lowest concentration level. Uncertainty budgets calculated for the three procedures revealed that intercept and slope were the most important factors contributing to uncertainty for Cal-IS. The main factors for wCal-IS and IPD were the volumes of sample and/or standard measured.The authors acknowledge financial support from the Generalitat Valenciana (Research group of excellence Prometeo II 2014/023 and Collaborative Research on Environment and Food Safety ISIC/2012/016), as well as University Jaume I for project PB1-1B2013-55. Finally, the authors are grateful to the Serveis Centrals d'Instrumentació Científica (SCIC) of University Jaume I for using Acquity and TQD instruments

    Quantitative plasma profiling by 1H NMR-based metabolomics: impact of sample treatment

    Get PDF
    Introduction: There is evidence that sample treatment of blood-based biosamples may affect integral signals in nuclear magnetic resonance-based metabolomics. The presence of macromolecules in plasma/serum samples makes investigating low-molecular-weight metabolites challenging. It is particularly relevant in the targeted approach, in which absolute concentrations of selected metabolites are often quantified based on the area of integral signals. Since there are a few treatments of plasma/serum samples for quantitative analysis without a universally accepted method, this topic remains of interest for future research.Methods: In this work, targeted metabolomic profiling of 43 metabolites was performed on pooled plasma to compare four methodologies consisting of Carr-Purcell-Meiboom-Gill (CPMG) editing, ultrafiltration, protein precipitation with methanol, and glycerophospholipid solid-phase extraction (g-SPE) for phospholipid removal; prior to NMR metabolomics analysis. The effect of the sample treatments on the metabolite concentrations was evaluated using a permutation test of multiclass and pairwise Fisher scores.Results: Results showed that methanol precipitation and ultrafiltration had a higher number of metabolites with coefficient of variation (CV) values above 20%. G-SPE and CPMG editing demonstrated better precision for most of the metabolites analyzed. However, differential quantification performance between procedures were metabolite-dependent. For example, pairwise comparisons showed that methanol precipitation and CPMG editing were suitable for quantifying citrate, while g-SPE showed better results for 2-hydroxybutyrate and tryptophan.Discussion: There are alterations in the absolute concentration of various metabolites that are dependent on the procedure. Considering these alterations is essential before proceeding with the quantification of treatment-sensitive metabolites in biological samples for improving biomarker discovery and biological interpretations. The study demonstrated that g-SPE and CPMG editing are effective methods for removing proteins and phospholipids from plasma samples for quantitative NMR analysis of metabolites. However, careful consideration should be given to the specific metabolites of interest and their susceptibility to the sample treatment procedures. These findings contribute to the development of optimized sample preparation protocols for metabolomics studies using NMR spectroscopy

    Clinical and pathological characteristics of peripheral T-cell lymphomas in a Spanish population: a retrospective study

    Get PDF
    We investigated the clinicopathological features and prognostic factors of patients with peripheral T-cell lymphoma (PTCL) in 13 sites across Spain. Relevant clinical antecedents, CD30 expression and staining pattern, prognostic indices using the International Prognostic Index and the Intergruppo Italiano Linfomi system, treatments, and clinical outcomes were examined. A sizeable proportion of 175 patients had a history of immune-related disorders (autoimmune 16%, viral infections 17%, chemo/radiotherapy-treated carcinomas 19%). The median progression-free survival (PFS) and overall survival (OS) were 7·9 and 15·8 months, respectively. Prognostic indices influenced PFS and OS, with a higher number of adverse factors resulting in shorter survival (P 15% of cells were positive in anaplastic lymphoma kinase-positive and -negative anaplastic large-cell lymphoma and extranodal natural killer PTCL groups. We observed PTCL distribution across subtypes based on haematopathological re-evaluation. Poor prognosis, effect of specific prognostic indices, relevance of histopathological sub-classification, and response level to first-line treatment on outcomes were confirmed. Immune disorders amongst patients require further examination involving genetic studies and identification of associated immunosuppressive factors.This study was sponsored by Takeda
    corecore