519 research outputs found

    Flow Property Measurement Using Laser-Induced Fluorescence in the NASA Ames Interaction Heating Facility

    Get PDF
    The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (TALIF) of atomic species has been applied to single-point measurements of velocity and static temperature in the NASA Ames Interaction Heating Facility (IHF) arc jet. Excitation spectra of atomic oxygen and nitrogen were recorded while scanning a tunable dye laser over the absorption feature. Thirty excitation spectra were acquired during 8 arc jet runs at two facility operating conditions; the number of scans per run varied between 2 and 6. Curve fits to the spectra were analyzed to recover their Doppler shifts and widths, from which the flow velocities and static temperatures, respectively, were determined. An increase in the number of independent flow property pairs from each as-measured scan was obtained by extracting multiple lower-resolution scans. The larger population sample size enabled the mean property values and their uncertainties for each run to be characterized with greater confidence. The average plus or minus 2 sigma uncertainties in the mean velocities and temperatures for all 8 runs were plus or minus 1.4% and plus or minus 11%, respectively

    Identification of Noise Sources During Rocket Engine Test Firings and a Rocket Launch Using a Microphone Phased-Array

    Get PDF
    A 70 microphone, 10-foot by 10-foot, microphone phased array was built for use in the harsh environment of rocket launches. The array was setup at NASA Wallops launch pad 0A during a static test firing of Orbital Sciences' Antares engines, and again during the first launch of the Antares vehicle. It was placed 400 feet away from the pad, and was hoisted on a scissor lift 40 feet above ground. The data sets provided unprecedented insight into rocket noise sources. The duct exit was found to be the primary source during the static test firing; the large amount of water injected beneath the nozzle exit and inside the plume duct quenched all other sources. The maps of the noise sources during launch were found to be time-dependent. As the engines came to full power and became louder, the primary source switched from the duct inlet to the duct exit. Further elevation of the vehicle caused spilling of the hot plume, resulting in a distributed noise map covering most of the pad. As the entire plume emerged from the duct, and the ondeck water system came to full power, the plume itself became the loudest noise source. These maps of the noise sources provide vital insight for optimization of sound suppression systems for future Antares launches

    Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

    Get PDF
    The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (TALIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. Use of TALIF expanded at NASA Ames and to NASA Johnson's arc jet facility in the late 2000s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the original AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper documents the overall system design from measurement requirements to implementation. Representative data from the redeveloped AHF and IHF LIF systems are also presented

    Denial at the top table: status attributions and implications for marketing

    Get PDF
    Senior marketing management is seldom represented on the Board of Directors nowadays, reflecting a deteriorating status of the marketing profession. We examine some of the key reasons for marketing’s demise, and discuss how the status of marketing may be restored by demonstrating the value of marketing to the business community. We attribute marketing’s demise to several related key factors: narrow typecasting, marginalisation and limited involvement in product development, questionable marketing curricula, insensitivity toward environmental change, questionable professional standards and roles, and marketing’s apparent lack of accountability to CEOs. Each of these leads to failure to communicate, create, or deliver value within marketing. We argue that a continued inability to deal with marketing’s crisis of representation will further erode the status of the discipline both academically and professionally

    DNA double-strand breaks induce H2Ax phosphorylation domains in a contact-dependent manner

    Get PDF
    Formation of γH2Ax serves as a checkpoint for double-strand break (DSB) repair pathways. Here the authors reveal via integrated chromatin analysis that γH2Ax domains are established by chromosomal contacts with the DSB site

    Partner-assisted emotional disclosure for patients with gastrointestinal cancer: Results from a randomized controlled trial

    Get PDF
    For patients with cancer who are married or in an intimate relationship, their relationships with their partners play a critical role in their adaptation to their illness. However, cancer patients and their partners often have difficulty in talking with each other about their cancer-related concerns. Difficulties in communication may ultimately compromise both the patient-partner relationship and the patient's psychological adjustment. The present study tested the efficacy of a novel partner-assisted emotional disclosure intervention in a sample of patients with gastrointestinal (GI) cancer

    Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan.

    Get PDF
    BACKGROUND: There is a need to standardise non-invasive measurements of liver iron concentrations (LIC) so clear inferences can be drawn about body iron levels that are associated with hepatic and extra-hepatic complications of iron overload. Since the first demonstration of an inverse relationship between biopsy LIC and liver magnetic resonance (MR) using a proof-of-concept T2* sequence, MR technology has advanced dramatically with a shorter minimum echo-time, closer inter-echo spacing and constant repetition time. These important advances allow more accurate calculation of liver T2* especially in patients with high LIC. METHODS: Here, we used an optimised liver T2* sequence calibrated against 50 liver biopsy samples on 25 patients with transfusional haemosiderosis using ordinary least squares linear regression, and assessed the method reproducibility in 96 scans over an LIC range up to 42 mg/g dry weight (dw) using Bland-Altman plots. Using mixed model linear regression we compared the new T2*-LIC with R2-LIC (Ferriscan) on 92 scans in 54 patients with transfusional haemosiderosis and examined method agreement using Bland-Altman approach. RESULTS: Strong linear correlation between ln(T2*) and ln(LIC) led to the calibration equation LIC = 31.94(T2*)-1.014. This yielded LIC values approximately 2.2 times higher than the proof-of-concept T2* method. Comparing this new T2*-LIC with the R2-LIC (Ferriscan) technique in 92 scans, we observed a close relationship between the two methods for values up to 10 mg/g dw, however the method agreement was poor. CONCLUSIONS: New calibration of T2* against liver biopsy estimates LIC in a reproducible way, correcting the proof-of-concept calibration by 2.2 times. Due to poor agreement, both methods should be used separately to diagnose or rule out liver iron overload in patients with increased ferritin

    Climate geoengineering: issues of path-dependence and socio-technical lock-in

    Get PDF
    As academic and policy interest in climate geoengineering grows, the potential irreversibility of technological developments in this domain has been raised as a pressing concern. The literature on socio-technical lock-in and path dependence is illuminating in helping to situate current concerns about climate geoengineering and irreversibility in the context of academic understandings of historical socio-technical development and persistence. This literature provides a wealth of material illustrating the pervasiveness of positive feedbacks of various types (from the discursive to the material) leading to complex socio-technical entanglements which may resist change and become inflexible even in the light of evidence of negative impacts. With regard to climate geoengineering, there are concerns that geoengineering technologies might contribute so-called ‘carbon lock-in’, or become irreversibly ‘locked-in’ themselves. In particular, the scale of infrastructures that geoengineering interventions would require, and the issue of the so-called ‘termination effect’ have been discussed in these terms. Despite the emergent and somewhat ill-defined nature of the field, some authors also suggest that the extant framings of geoengineering in academic and policy literatures may already demonstrate features recognizable as forms of cognitive lock-in, likely to have profound implications for future developments in this area. While the concepts of path-dependence and lock-in are the subject of ongoing academic critique, by drawing analytical attention to these pervasive processes of positive feedback and entanglement, this literature is highly relevant to current debates around geoengineering

    Calibration of myocardial T2 and T1 against iron concentration.

    Get PDF
    BACKGROUND: The assessment of myocardial iron using T2* cardiovascular magnetic resonance (CMR) has been validated and calibrated, and is in clinical use. However, there is very limited data assessing the relaxation parameters T1 and T2 for measurement of human myocardial iron. METHODS: Twelve hearts were examined from transfusion-dependent patients: 11 with end-stage heart failure, either following death (n=7) or cardiac transplantation (n=4), and 1 heart from a patient who died from a stroke with no cardiac iron loading. Ex-vivo R1 and R2 measurements (R1=1/T1 and R2=1/T2) at 1.5 Tesla were compared with myocardial iron concentration measured using inductively coupled plasma atomic emission spectroscopy. RESULTS: From a single myocardial slice in formalin which was repeatedly examined, a modest decrease in T2 was observed with time, from mean (± SD) 23.7 ± 0.93 ms at baseline (13 days after death and formalin fixation) to 18.5 ± 1.41 ms at day 566 (p<0.001). Raw T2 values were therefore adjusted to correct for this fall over time. Myocardial R2 was correlated with iron concentration [Fe] (R2 0.566, p<0.001), but the correlation was stronger between LnR2 and Ln[Fe] (R2 0.790, p<0.001). The relation was [Fe] = 5081•(T2)-2.22 between T2 (ms) and myocardial iron (mg/g dry weight). Analysis of T1 proved challenging with a dichotomous distribution of T1, with very short T1 (mean 72.3 ± 25.8 ms) that was independent of iron concentration in all hearts stored in formalin for greater than 12 months. In the remaining hearts stored for <10 weeks prior to scanning, LnR1 and iron concentration were correlated but with marked scatter (R2 0.517, p<0.001). A linear relationship was present between T1 and T2 in the hearts stored for a short period (R2 0.657, p<0.001). CONCLUSION: Myocardial T2 correlates well with myocardial iron concentration, which raises the possibility that T2 may provide additive information to T2* for patients with myocardial siderosis. However, ex-vivo T1 measurements are less reliable due to the severe chemical effects of formalin on T1 shortening, and therefore T1 calibration may only be practical from in-vivo human studies
    corecore