53 research outputs found

    Controlling TcT_c of Iridium films using interfacial proximity effects

    Full text link
    High precision calorimetry using superconducting transition edge sensors requires the use of superconducting films with a suitable TcT_c, depending on the application. To advance high-precision macrocalorimetry, we require low-TcT_c films that are easy to fabricate. A simple and effective way to suppress TcT_c of superconducting Iridium through the proximity effect is demonstrated by using Ir/Pt bilayers as well as Au/Ir/Au trilayers. While Ir/Au films fabricated by applying heat to the substrate during Ir deposition have been used in the past for superconducting sensors, we present results of TcT_c suppression on Iridium by deposition at room temperature in Au/Ir/Au trilayers and Ir/Pt bilayers in the range of \sim20-100~mK. Measurements of the relative impedance between the Ir/Pt bilayers and Au/Ir/Au trilayers fabricated show factor of \sim10 higher values in the Ir/Pt case. These new films could play a key role in the development of scalable superconducting transition edge sensors that require low-TcT_c films to minimize heat capacity and maximize energy resolution, while keeping high-yield fabrication methods.Comment: 5 journal pages, 4 figure

    Controlling TcT_c of Iridium Films Using the Proximity Effect

    Full text link
    A superconducting Transition-Edge Sensor (TES) with low-TcT_c is essential in a high resolution calorimetric detection. With a motivation of developing sensitive calorimeters for applications in cryogenic neutrinoless double beta decay searches, we have been investigating methods to reduce the TcT_c of an Ir film down to 20 mK. Utilizing the proximity effect between a superconductor and a normal metal, we found two room temperature fabrication recipes of making Ir-based low-TcT_c films. In the first approach, an Ir film sandwiched between two Au films, a Au/Ir/Au trilayer, has a tunable TcT_c in the range of 20-100 mK depending on the relative thicknesses. In the second approach, a paramagnetic Pt thin film is used to create Ir/Pt bilayer with a tunable TcT_c in the same range. We present detailed study of fabrication and characterization of Ir-based low-TcT_c films, and compare the experimental results to theoretical models. We show that Ir-based films with predictable and reproducible critical temperature can be consistently fabricated for use in large scale detector applications.Comment: 5 figures, accepted in the Journal of Applied Physic

    Quantitative plane-resolved crystal growth and dissolution kinetics by coupling in situ optical microscopy and diffusion models : the case of salicylic acid in aqueous solution

    Get PDF
    The growth and dissolution kinetics of salicylic acid crystals are investigated in situ by focusing on individual microscale crystals. From a combination of optical microscopy and finite element method (FEM) modeling, it was possible to obtain a detailed quantitative picture of dissolution and growth dynamics for individual crystal faces. The approach uses real-time in situ growth and dissolution data (crystal size and shape as a function of time) to parametrize a FEM model incorporating surface kinetics and bulk to surface diffusion, from which concentration distributions and fluxes are obtained directly. It was found that the (001) face showed strong mass transport (diffusion) controlled behavior with an average surface concentration close to the solubility value during growth and dissolution over a wide range of bulk saturation levels. The (1̅10) and (110) faces exhibited mixed mass transport/surface controlled behavior, but with a strong diffusive component. As crystals became relatively large, they tended to exhibit peculiar hollow structures in the end (001) face, observed by interferometry and optical microscopy. Such features have been reported in a number of crystals, but there has not been a satisfactory explanation for their origin. The mass transport simulations indicate that there is a large difference in flux across the crystal surface, with high values at the edge of the (001) face compared to the center, and this flux has to be redistributed across the (001) surface. As the crystal grows, the redistribution process evidently can not be maintained so that the edges grow at the expense of the center, ultimately creating high index internal structures. At later times, we postulate that these high energy faces, starved of material from solution, dissolve and the extra flux of salicylic acid causes the voids to close

    Ethnic mobilization among Korean dry-cleaners

    Full text link
    Korean immigrants in the U.S. rely heavily on ethnic resources to start small businesses.  Ethnic resources include business networks and knowledge, start-up capital, and access to labor power that are embedded in networks of family, friends, and co-ethnics.  This paper shows how Korean dry cleaners in Southern California used ethnic resources to mobilize in response to an environmental policy initiated by the South Coast Air Quality Management District (AQMD).  While Korean immigrants used ethnic resources to start dry cleaning businesses, they found themselves working with a toxic chemical.  In 2002, AQMD required dry cleaners in Southern California to convert to costly alternative machines by 2020.  Korean dry cleaners used ethnic-based collective action, particularly the Korean Dry Cleaning Association, as a means of fighting for regulatory concessions.  They also used ethnic resources to overcome cultural and linguistic barriers to facilitate the adoption of alternative cleaning machines in compliance with the regulation.   &nbsp

    Tuning the activity/stability balance of anion doped CoSxSe2−x dichalcogenides

    Full text link
    We present a thorough assessment of the compositional dependent hydrogen evolution reaction (HER) activity and stability for Co-based mixed chalcogen, CoSxSe2−x, transition metal dichalcogenides (TMDs). In direct contrast to other reports on mixed chalcogen TMDs that have been limited to Mo and W, we observe a decrease in HER activity for any departure from the pure, single chalcogen composition, CoS2 and CoSe2. The single chalcogen TMDs are found to have nearly identical HER activity. Bulk resistivity of the pure and mixed chalcogen TMDs as well as the charge transfer resistance for the HER are found to be most optimal for CoSe2. However, CoSe2 is predicted to have an endothermic hydrogen adsorption free energy in contrast to the slightly exothermic hydrogen adsorption free energy for CoS2. This highlights the convolution of hydrogen adsorption free energy and material conductivity in determining the HER activity for even metallic conducting TMDs. Sulfur-rich Co-based TMDs with a pyrite-type crystal structure are found to quickly deactivate through loss of Co and formation of passivating reduced sulfur species at the surface while Se-rich compositions are observed to be more stable. Therefore, with an HER activity matching that of CoS2, but with a dramatic improvement in stability, CoSe2 breaks away from the traditional inverse activity – stability relationship and represents a promising non-PGM HER electrocatalyst for acidic PEM electrolyzers. © 2018 Elsevier Inc

    A CUPID Li2100MoO4scintillating bolometer tested in the CROSS underground facility

    Get PDF
    A scintillating bolometer based on a large cubic Li2100MoO4 crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation 0¿2ß experiment CUPID . The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li2100MoO4 bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV ¿ line. The detection of scintillation light for each event triggered by the Li2100MoO4 bolometer allowed for a full separation (~8s) between ¿(ß) and a events above 2 MeV . The Li2100MoO4 crystal also shows a high internal radiopurity with 228Th and 226Ra activities of less than 3 and 8 µBq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li2100MoO4 scintillating bolometers for high-sensitivity searches for the 100Mo 0¿2ß decay in CROSS and CUPID projects

    Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries.

    Get PDF
    BACKGROUND: As global initiatives increase patient access to surgical treatments, there remains a need to understand the adverse effects of surgery and define appropriate levels of perioperative care. METHODS: We designed a prospective international 7-day cohort study of outcomes following elective adult inpatient surgery in 27 countries. The primary outcome was in-hospital complications. Secondary outcomes were death following a complication (failure to rescue) and death in hospital. Process measures were admission to critical care immediately after surgery or to treat a complication and duration of hospital stay. A single definition of critical care was used for all countries. RESULTS: A total of 474 hospitals in 19 high-, 7 middle- and 1 low-income country were included in the primary analysis. Data included 44 814 patients with a median hospital stay of 4 (range 2-7) days. A total of 7508 patients (16.8%) developed one or more postoperative complication and 207 died (0.5%). The overall mortality among patients who developed complications was 2.8%. Mortality following complications ranged from 2.4% for pulmonary embolism to 43.9% for cardiac arrest. A total of 4360 (9.7%) patients were admitted to a critical care unit as routine immediately after surgery, of whom 2198 (50.4%) developed a complication, with 105 (2.4%) deaths. A total of 1233 patients (16.4%) were admitted to a critical care unit to treat complications, with 119 (9.7%) deaths. Despite lower baseline risk, outcomes were similar in low- and middle-income compared with high-income countries. CONCLUSIONS: Poor patient outcomes are common after inpatient surgery. Global initiatives to increase access to surgical treatments should also address the need for safe perioperative care. STUDY REGISTRATION: ISRCTN5181700

    ATHENA detector proposal - a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider

    Get PDF
    ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity.This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges
    corecore