1,092 research outputs found

    A screening protocol incorporating brain-computer interface feature matching considerations for augmentative and alternative communication

    Get PDF
    Purpose: The use of standardized screening protocols may inform brain-computer interface (BCI) research procedures to help maximize BCI performance outcomes and provide foundational information for clinical translation. Therefore, in this study we developed and evaluated a new BCI screening protocol incorporating cognitive, sensory, motor and motor imagery tasks. Methods: Following development, BCI screener outcomes were compared to the Amyotrophic Lateral Sclerosis Cognitive Behavioral Screen (ALS-CBS), and ALS Functional Rating Scale (ALS-FRS) for twelve individuals with a neuromotor disorder. Results: Scores on the cognitive portion of the BCI screener demonstrated limited variability, indicating all participants possessed core BCI-related skills. When compared to the ALS-CBS, the BCI screener was able to modestly discriminate possible cognitive difficulties that are likely to influence BCI performance. In addition, correlations between the motor imagery section of the screener and ALS-CBS and ALS-FRS were non-significant, suggesting the BCI screener may provide information not captured on other assessment tools. Additional differences were found between motor imagery tasks, with greater self-ratings on first-person explicit imagery of familiar tasks compared to unfamiliar/ generic BCI tasks. Conclusion: The BCI screener captures factors likely relevant for BCI, which has value for guiding person-centered BCI assessment across different devices to help inform BCI trials. Includes supplemental data

    Motor-Induced Suppression of the N100 Event-Related Potential During Motor Imagery Control of a Speech Synthesizer Brain–Computer Interface

    Get PDF
    Purpose: Speech motor control relies on neural processes for generating sensory expectations using an efference copy mechanism to maintain accurate productions. The N100 auditory event-related potential (ERP) has been identified as a possible neural marker of the efference copy with a reduced amplitude during active listening while speaking when compared to passive listening. This study investigates N100 suppression while controlling a motor imagery speech synthesizer brain–computer interface (BCI) with instantaneous auditory feedback to determine whether similar mechanisms are used for monitoring BCI-based speech output that may both support BCI learning through existing speech motor networks and be used as a clinical marker for the speech network integrity in individuals without severe speech and physical impairments. Method: The motor-induced N100 suppression is examined based on data from 10 participants who controlled a BCI speech synthesizer using limb motor imagery. We considered listening to auditory target stimuli (without motor imagery) in the BCI study as passive listening and listening to BCI-controlled speech output (with motor imagery) as active listening since audio output depends on imagined movements. The resulting ERP was assessed for statistical significance using a mixed-effects general linear model. Results: Statistically significant N100 ERP amplitude differences were observed between active and passive listening during the BCI task. Post hoc analyses confirm the N100 amplitude was suppressed during active listening. Conclusion: Observation of the N100 suppression suggests motor planning brain networks are active as participants control the BCI synthesizer, which may aid speech BCI mastery

    Guidelines for Feature Matching Assessment of Brain–Computer Interfaces for Augmentative and Alternative Communication

    Get PDF
    Purpose--Brain–computer interfaces (BCIs) can provide access to augmentative and alternative communication (AAC) devices using neurological activity alone without voluntary movements. As with traditional AAC access methods, BCI performance may be influenced by the cognitive–sensory–motor and motor imagery profiles of those who use these devices. Therefore, we propose a person-centered, feature matching framework consistent with clinical AAC best practices to ensure selection of the most appropriate BCI technology to meet individuals\u27 communication needs. Method--The proposed feature matching procedure is based on the current state of the art in BCI technology and published reports on cognitive, sensory, motor, and motor imagery factors important for successful operation of BCI devices. Results--Considerations for successful selection of BCI for accessing AAC are summarized based on interpretation from a multidisciplinary team with experience in AAC, BCI, neuromotor disorders, and cognitive assessment. The set of features that support each BCI option are discussed in a hypothetical case format to model possible transition of BCI research from the laboratory into clinical AAC applications. Conclusions--This procedure is an initial step toward consideration of feature matching assessment for the full range of BCI devices. Future investigations are needed to fully examine how person-centered factors influence BCI performance across devices

    A Noninvasive Brain-Computer Interface for Real-Time Speech Synthesis: The Importance of Multimodal Feedback.

    Get PDF
    We conducted a study of a motor imagery brain-computer interface (BCI) using electroencephalography to continuously control a formant frequency speech synthesizer with instantaneous auditory and visual feedback. Over a three-session training period, sixteen participants learned to control the BCI for production of three vowel sounds (/ textipa i/ [heed], / textipa A/ [hot], and / textipa u/ [who'd]) and were split into three groups: those receiving unimodal auditory feedback of synthesized speech, those receiving unimodal visual feedback of formant frequencies, and those receiving multimodal, audio-visual (AV) feedback. Audio feedback was provided by a formant frequency artificial speech synthesizer, and visual feedback was given as a 2-D cursor on a graphical representation of the plane defined by the first two formant frequencies. We found that combined AV feedback led to the greatest performance in terms of percent accuracy, distance to target, and movement time to target compared with either unimodal feedback of auditory or visual information. These results indicate that performance is enhanced when multimodal feedback is meaningful for the BCI task goals, rather than as a generic biofeedback signal of BCI progress

    Examining sensory ability, feature matching, and assessment-based adaptation for a brain-computer interface using the steady-state visually evoked potential

    Get PDF
    This is an Accepted Manuscript of an article published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology on 01/31/2018, available online: http://www.tandfonline.com/10.1080/17483107.2018.1428369.PURPOSE:We investigated how overt visual attention and oculomotor control influence successful use of a visual feedback brain-computer interface (BCI) for accessing augmentative and alternative communication (AAC) devices in a heterogeneous population of individuals with profound neuromotor impairments. BCIs are often tested within a single patient population limiting generalization of results. This study focuses on examining individual sensory abilities with an eye toward possible interface adaptations to improve device performance. METHODS: Five individuals with a range of neuromotor disorders participated in four-choice BCI control task involving the steady state visually evoked potential. The BCI graphical interface was designed to simulate a commercial AAC device to examine whether an integrated device could be used successfully by individuals with neuromotor impairment. RESULTS: All participants were able to interact with the BCI and highest performance was found for participants able to employ an overt visual attention strategy. For participants with visual deficits to due to impaired oculomotor control, effective performance increased after accounting for mismatches between the graphical layout and participant visual capabilities. CONCLUSION: As BCIs are translated from research environments to clinical applications, the assessment of BCI-related skills will help facilitate proper device selection and provide individuals who use BCI the greatest likelihood of immediate and long term communicative success. Overall, our results indicate that adaptations can be an effective strategy to reduce barriers and increase access to BCI technology. These efforts should be directed by comprehensive assessments for matching individuals to the most appropriate device to support their complex communication needs. Implications for Rehabilitation Brain computer interfaces using the steady state visually evoked potential can be integrated with an augmentative and alternative communication device to provide access to language and literacy for individuals with neuromotor impairment. Comprehensive assessments are needed to fully understand the sensory, motor, and cognitive abilities of individuals who may use brain-computer interfaces for proper feature matching as selection of the most appropriate device including optimization device layouts and control paradigms. Oculomotor impairments negatively impact brain-computer interfaces that use the steady state visually evoked potential, but modifications to place interface stimuli and communication items in the intact visual field can improve successful outcomes

    Dendritic cell–derived exosomes for cancer therapy

    Get PDF
    International audienceDC-derived exosomes (Dex) are nanometer-sized membrane vesicles that are secreted by the sentinel antigen-presenting cells of the immune system: DCs. Like DCs, the molecular composition of Dex includes surface expression of functional MHC-peptide complexes, costimulatory molecules, and other components that interact with immune cells. Dex have the potential to facilitate immune cell–dependent tumor rejection and have distinct advantages over cell-based immunotherapies involving DCs. Accordingly, Dex-based phase I and II clinical trials have been conducted in advanced malignancies, showing the feasibility and safety of the approach, as well as the propensity of these nanovesicles to mediate T and NK cell–based immune responses in patients. This Review will evaluate the interactions of Dex with immune cells, their clinical progress, and the future of Dex immunotherapy for cancer

    Quantification of functionalised gold nanoparticle-targeted knockdown of gene expression in HeLa cells

    Get PDF
    Introduction: Gene therapy continues to grow as an important area of research, primarily because of its potential in the treatment of disease. One significant area where there is a need for better understanding is in improving the efficiency of oligonucleotide delivery to the cell and indeed, following delivery, the characterization of the effects on the cell. Methods: In this report, we compare different transfection reagents as delivery vehicles for gold nanoparticles functionalized with DNA oligonucleotides, and quantify their relative transfection efficiencies. The inhibitory properties of small interfering RNA (siRNA), single-stranded RNA (ssRNA) and single-stranded DNA (ssDNA) sequences targeted to human metallothionein hMT-IIa are also quantified in HeLa cells. Techniques used in this study include fluorescence and confocal microscopy, qPCR and Western analysis. Findings: We show that the use of transfection reagents does significantly increase nanoparticle transfection efficiencies. Furthermore, siRNA, ssRNA and ssDNA sequences all have comparable inhibitory properties to ssDNA sequences immobilized onto gold nanoparticles. We also show that functionalized gold nanoparticles can co-localize with autophagosomes and illustrate other factors that can affect data collection and interpretation when performing studies with functionalized nanoparticles. Conclusions: The desired outcome for biological knockdown studies is the efficient reduction of a specific target; which we demonstrate by using ssDNA inhibitory sequences targeted to human metallothionein IIa gene transcripts that result in the knockdown of both the mRNA transcript and the target protein

    Chaste: an open source C++ library for computational physiology and biology

    Get PDF
    Chaste - Cancer, Heart And Soft Tissue Environment - is an open source C++ library for the computational simulation of mathematical models developed for physiology and biology. Code development has been driven by two initial applications: cardiac electrophysiology and cancer development. A large number of cardiac electrophysiology studies have been enabled and performed, including high performance computational investigations of defibrillation on realistic human cardiac geometries. New models for the initiation and growth of tumours have been developed. In particular, cell-based simulations have provided novel insight into the role of stem cells in the colorectal crypt. Chaste is constantly evolving and is now being applied to a far wider range of problems. The code provides modules for handling common scientific computing components, such as meshes and solvers for ordinary and partial differential equations (ODEs/PDEs). Re-use of these components avoids the need for researchers to "re-invent the wheel" with each new project, accelerating the rate of progress in new applications. Chaste is developed using industrially-derived techniques, in particular test-driven development, to ensure code quality, re-use and reliability. In this article we provide examples that illustrate the types of problems Chaste can be used to solve, which can be run on a desktop computer. We highlight some scientific studies that have used or are using Chaste, and the insights they have provided. The source code, both for specific releases and the development version, is available to download under an open source Berkeley Software Distribution (BSD) licence at http://www.cs.ox.ac.uk/chaste, together with details of a mailing list and links to documentation and tutorials
    corecore