13 research outputs found

    Clinical significance of bronchodilator responsiveness evaluated by forced vital capacity in COPD: SPIROMICS cohort analysis

    Get PDF
    Objective: Bronchodilator responsiveness (BDR) is prevalent in COPD, but its clinical implications remain unclear. We explored the significance of BDR, defined by post-bronchodilator change in FEV1 (BDRFEV1) as a measure reflecting the change in flow and in FVC (BDRFVC)reflecting the change in volume. Methods: We analyzed 2974 participants from a multicenter observational study designed to identify varying COPD phenotypes (SPIROMICS). We evaluated the association of BDR with baseline clinical characteristics, rate of prospective exacerbations and mortality using negative binomial regression and Cox proportional hazards models. Results: A majority of COPD participants exhibited BDR (52.7%). BDRFEV1 occurred more often in earlier stages of COPD, while BDRFVC occurred more frequently in more advanced disease. When defined by increases in either FEV1 or FVC, BDR was associated with a self-reported history of asthma, but not with blood eosinophil counts. BDRFVC was more prevalent in subjects with greater emphysema and small airway disease on CT. In a univariate analysis, BDRFVC was associated with increased exacerbations and mortality, although no significance was found in a model adjusted for post-bronchodilator FEV1. Conclusion: With advanced airflow obstruction in COPD, BDRFVC is more prevalent in comparison to BDRFEV1 and correlates with the extent of emphysema and degree of small airway disease. Since these associations appear to be related to the impairment of FEV1,BDRFVC itself does not define a distinct phenotype nor can it be more predictive of outcomes, but it can offer additional insights into the pathophysiologic mechanism in advanced COPD. Clinical trials registration: ClinicalTrials.gov: NCT01969344T4

    Associations Among 25-Hydroxyvitamin D Levels, Lung Function, and Exacerbation Outcomes in COPD: An Analysis of the SPIROMICS Cohort

    Get PDF
    Background: The relationship between 25-hydroxyvitamin D (25-OH-vitamin D) and COPD outcomes remains unclear. Using the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS), we determined associations among baseline 25-OH-vitamin D and cross-sectional and longitudinal lung function and COPD exacerbations. Methods: Serum 25-OH-vitamin D level was measured in stored samples from 1,609 SPIROMICS participants with COPD. 25-OH-vitamin D levels were modeled continuously and dichotomized as deficient (< 20 ng/mL) vs not deficient (≄ 20 ng/mL). Outcomes of interest included % predicted FEV1 (current and 1-year longitudinal decline) and COPD exacerbations (separately any and severe, occurring in prior year and first year of follow-up). Results: Vitamin D deficiency was present in 21% of the cohort and was more prevalent in the younger, active smokers, and blacks. Vitamin D deficiency was independently associated with lower % predicted FEV1 (by 4.11%) at enrollment (95% CI, –6.90% to –1.34% predicted FEV1; P =.004), 1.27% predicted greater rate of FEV1 decline after 1 year (95% CI, –2.32% to –0.22% predicted/y; P =.02), and higher odds of any COPD exacerbation in the prior year (OR, 1.32; 95% CI, 1.00-1.74; P =.049). Each 10-ng/mL decrease in 25-OH-vitamin D was associated with lower baseline lung function (–1.04% predicted; 95% CI, –1.96% to –0.12% predicted; P =.03) and increased odds of any exacerbation in the year before enrollment (OR, 1.11; 95% CI, 1.01-1.22; P =.04). Conclusions: Vitamin D deficiency is associated with worse cross-sectional and longitudinal lung function and increased odds of prior COPD exacerbations. These findings identify 25-OH-vitamin D levels as a potentially useful marker of adverse COPD-related outcomes

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    Detection of pseudoscalar and scalar mesons at DAFNE with KLOE

    No full text
    Codice SCOPUS: 2-s2.0-0034738246 Codice ISI non disponibile The KLOE experiment at the DAfNE f-factory has just started collecting data. One of the first analysis items is the study of the f radiative decays, which allows us to investigate the nature of light pseudoscalar and scalar mesons. An integrated luminosity of 100 pb−1 is expected for next KLOE run, resulting in 3 × 108 f collected. A detailed simulation and full event reconstruction of both signal and background events indicates a sensitivity reach of 1 Ă· 2% on the branching ratios. Some preliminary studies on real data are also presented, showing a good agreement with MonteCarlo distribution

    THE KLOE DRIFT CHAMBER

    No full text

    KLOE at DA Phi NE

    No full text

    Mouse Chromosome 2

    No full text

    KLOE at DAPHNE

    No full text
    corecore